Operation Instructions for Heater Roll Welding Machine
1、 Working Voltage: Three-phaseAC380V +10% ,50Hz + 1%。
2、 Work Environment:No frost from 0 to 45°C, humidity ≤ 85% with no condensation.
3、 Maintenance: Add lubricating conductive grease per shift3 times; clean the water circulation filter daily; clean the water tank sediment every 3 days; change the water every 20 days; use pure water for cooling in summer and antifreeze for cooling in winter; replace the transmission gear oil once a month; dust collection and cleaning daily.
4、 Operation Method: After selecting the processing specification, the welder automatically applies pressure, rotates, welds, and stops upon closing the foot pedal switch. When the foot pedal switch is closed to stop, all actions are disconnected.
5、 Work must be conducted with protective spark splash gear to prevent personal injury.
6、 Welding machines generate high temperatures, causing the conductive copper wheels to wear with use. If the copper wheels deform, accumulate weld slag, or require correction, they should be replaced or corrected promptly.
7、 Cooling Machine Operating Voltage: Three-phase, four-wireAC380V + 10% ,50Hz + 1%。
8、 Chiller operates normally during operationPerform a refrigerant charge check every 3 months.
9、 Extended downtime, please drain the water from the water-cooled unit to ensure it is dry.
10、 High-pressure gauge less than2.6mpa。
11、 Low rolling gauge0.2mpa。
12、 In case of other emergencies, please shut off the power and contact the supervisor.