Oxygen-Free Dual Control Oven/Oxygen-Free Dryer Features:
The manufacturing of oxygen-free ovens, all seams of the stainless steel inner shell are welded using argon arc welding, ensuring excellent sealing performance. It can quickly deoxygenate or cool down, contributing to product quality.
Main Application: Satisfies the anoxidation drying requirements for industries such as electronics, hygiene, instruments and meters, factories, universities, and scientific research.
I. Equipment Features
1. Welded with argon arc on the inner wall, high-temperature silicone gaskets ensure good airtightness.
2. High-temperature resistance, clean.
II. Compliance and Standard Fulfillment
GB/T11158-1989 Technical Conditions for High-Temperature Test Chambers
GB2423.2-1989 Test B
Section 3: Equipment Usage
The anaerobic oven is suitable for the production and scientific research departments of electronic liquid crystal displays, LCDs, CMOS, ICs, and laboratories.
The anaerobic oven can also be used for drying, heat treatment, aging, and other high-temperature tests for non-volatile and non-flammable, non-explosive items.
Section 4: Equipment Technical Specifications
Name and Model: Oxygen-Free Oven
2. Key Technical Specifications:
2.1 Oxygen Concentration: ≤0.5%
2.2 Temperature Range: RT (Room Temperature) +10 to +250℃
2.3 Temperature Deviation: ≤±2.0℃
2.4 Heating Rate: ≥3~5℃/min (average measurement throughout the process under no-load condition)
3. Case Structure:
3.1 Container Material: Outer box made of SS41# medium carbon steel plate, treated with phosphoric acid skin film salt and coated with two layers of anti-glare paint after baking varnishing.
3.2 Interior Material: Mirror finish stainless steel SUS304# with no magnetism.
3.3 Insulation Materials: Superfine Glass Wool
3.4 Exhaust Port: φ50
3.5 Separator: 2 layers, stainless steel square tube, bearing capacity of about 30KG.
3.6 Air Circulation Unit: High-capacity axial flow motor
3.7 Heating Method: Stainless steel electric heater
4. Temperature Control System
4.1 Temperature Measurement Sensor: Pt100 Platinum Resistance
4.2 Control Instrument: Imported digital temperature controller with PID adjustment, control accuracy of 0.1℃.
4.3 Over-temperature Protection Gauge: An independent over-temperature protection system separate from the main control of the laboratory, ensuring the safety of the test items.
4.4 Control System: Major electrical components are equipped with imported components from Schneider, Omron, and other brands.