As the saying goes, "You get what you pay for." Want to knowHorizontal exposed ceiling fan coil priceThe issue at hand, we must ascertain the value of this price, is it worth it? That is what we commonly refer to as the quality issue of fan coil units. So, how do we assess the quality of fan coil units? Below, we will provide a comprehensive and professional explanation by Shituo Air Conditioning Co., Ltd., the manufacturer of fan coil units. First, let's take a look at the horizontal surface-mounted fan coil unit pricing - cost - system cost?
World拓Air Conditioning Horizontal Ceiling Mounted Air Handling Unit Price - Price - System Price, the price for horizontal ceiling mounted air handling units ranges from $300 to $1700. The models, configurations, and application sites of horizontal ceiling mounted air handling units vary. Naturally, the price differs for different configurations. Before purchasing a horizontal ceiling mounted air handling unit, we need to know which specification and configuration you require. Alright, please refer to the professional horizontal ceiling mounted air handling unit price list provided by Dezhou World拓 Air Conditioning Equipment Co., Ltd. If you need a quote for other types of air handling units, please contact us promptly. Our price quotation staff will provide you with a quote in a timely manner. Please see the details below.
StandardHorizontal exposed ceiling fan coil price
FP-34 $550, FP-51 $580, FP-68 $600, FP-85 $650, FP-102 $680, FP-136 $900, FP-170 $960, FP-204 $1100, FP-238 $1300
Above is the quotation for horizontal exposed ceiling fan coil - price - system price of the standard configuration fan coil from Shituo Air Conditioning. Below, let's take a look at the price of the horizontal exposed ceiling fan coil with hydrophilic aluminum foil.
FP-34 $560, FP-51 $6100, FP-68 $610, FP-85 $670, FP-102 $690, FP-136 $910, FP-170 $970, FP-204 $1120, FP-238 $1320
Next, let's examine the quotation for horizontal exposed fan coil units, and then we'll look at the price of the gold foil for horizontal exposed fan coil units.
FP-34 $570, FP-51 $620, FP-68 $640, FP-85 $670, FP-102 $700, FP-136 $930, FP-170 $980, FP-204 $1150, FP-238 $1350
The quoted prices for these fans are the market rates for our pre-installed fan coils. If you need to replace the motor, please make a note of it before placing your order, so we can provide the replacement. Different motors will have different prices. If you need quotes for other fan coils, please call for contact.
We've reviewed the issues surrounding the horizontal exposed ceiling fan coil pricing, costs, and system pricing for Shituo Air Conditioning. Now, we must understand the core reasons for the high cost of horizontal exposed ceiling fan coils. Why is there a low market demand for horizontal exposed ceiling fan coils? Why aren't sales increasing? As central air conditioning fan coil terminal products, and all fan coils, why do different types of fan coils have such a large difference in sales? There is no difference in the quality of fan coils. This issue ultimately stems from the entire industry's market economy. Simply put, fan coils are all installed indoors, and they are installed before house renovations. Horizontal concealed ceiling fan coils are installed in the ceiling, offering a simple, elegant, and beautiful look without taking up any space. However, horizontal exposed ceiling fan coils are supported and fixed on the wall, taking up space and affecting aesthetics. Therefore, although horizontal exposed ceiling fan coils are installed indoors, the reason for their exposed installation is not well-received by the general public. This is the core reason for the low market demand for horizontal exposed ceiling fan coils. Well, that's all I can introduce about the reasons for the low market demand for horizontal exposed ceiling fan coils for now. If you have any further questions about horizontal exposed ceiling fan coils, please call our company's professional staff.
Friendly Reminder: Finally, let's examine the core of fan coil unit types and how to assess their quality. We must know that there are horizontal concealed (with return air box) fan coil units and...
Horizontal exposed ceiling fan coil
Vertical concealed ceiling fan coil
Vertical exposed ceiling fan coil
Carded Two Outflow Ceiling Fan Coil
Cartridge-type Four-Outlet Air Handling Unit Coil
Wall-mounted fan coil unit
Floor-standing Water Chiller Unit (commonly referred to as: Water Temperature Air Conditioning)
In form: horizontal concealed, horizontal exposed, vertical concealed, vertical exposed, and card type, totaling five types.
By thickness: ultra-thin, regular
By Condensate Pump: Standard, Deluxe
Static Pressure per Unit: 0Pa, 12Pa, 30Pa, 50Pa, 80Pa (external static pressure)
According to conduit quantity: two-row conduit, three-row conduit
By configuration: Two-pipe, four-pipe.
The term "several rows" in fan coil refers to the number of copper tubes in the coil. Generally, a two-row design consists of two rows of copper tubes, with eight tubes per row, totaling 16 tubes; a three-row design has three rows of copper tubes, with eight tubes per row, for a total of 24 tubes. The more copper tubes, the better the cooling effect.
Two-inch pipe size
The common fan coil unit uses chilled water for cooling in summer and hot water for heating in winter.
Four-pipe system
Commonly used in upscale venues, it allows for both hot and cold water flow simultaneously, enabling cooling in some rooms and heating in others as needed.
Low-noise electric motor
Pipe fittings and styles
Blade Wheel
Parameter changes affecting performance
As the temperature difference between the inlet and outlet of the fan coil increases, the water volume decreases, and the heat transfer coefficient of the heat exchange coil decreases accordingly. Additionally, the heat transfer temperature difference also changes. Therefore, the cooling capacity of the fan coil decreases as the temperature difference between the supply and return water increases. According to statistics, when the supply water temperature is 7°C and the supply and return water temperature difference increases from 5°C to 7°C, the cooling capacity can decrease by about 17%.
Customers selecting air-cooled chilled water units should first know where to assess the quality of the units.
Guarantee of heat (cold) transfer
Guaranteed air volume supply
Noise level value
Condensate water is not leaking
Rationality in electrical design
Rationality in sheet metal part design
How to distinguish between the good and bad of fan coil units
Listen to the noise - High-frequency can be removed, low-frequency is difficult to eliminate
Inspect the workmanship—burrs, gaps, manual, warranty card
Compare the materials used for motors, fans, water pans, and coils.
The motor is the core component of the unit, commonly found in Changzhou.
Fan: Source of Noise
Dishwasher, thermal insulation: Causes of dripping
Rolling stock: Hydrophilic aluminum (blue) or yellow nano-gold aluminum foil
Here, we must understand the configuration and specifications of the fan coil units to know the price range and to apply the model parameters correctly.
WindPCB (Printed Circuit Board)Piping main component configuration list
Serial Number | Material Name | Spec | Manufacturer |
1 | Motor | YDK/YSK Series | Dezhou Baite Electric Co., Ltd. Changzhou Jiangnan Kaihua Electric Co., Ltd. |
2 | Wind Turbine | B、CType | TexasHongyu Air Conditioning Accessories Co., Ltd. Texas Shituo Air Conditioning Equipment Co., Ltd. |
3 | Copper tubes | 9.52*0.3¢7mm | Inner Mongolia Chifeng Baoshan Energy (Group) Heqi Copper Industry Co., Ltd. |
Jinlong Precision Copper Tube Group Co., Ltd. | |||
4 | Aluminum foil | Hydrophilic δ0.105mm | Liaoning Dalian Huanghai Aluminum Industry Co., Ltd. |
Jiangsu Ding Sheng New Energy Materials Co., Ltd. | |||
5 | Box | Galvanized Sheet | Tianjin Tian Tie Metallurgical Group Co., Ltd. |
Tangshan Guofeng Iron and Steel Co., Ltd. | |||
Note: The condensate tray is made by one-time stamping and electrostatic spraying, with the same material as the box. Bearings: Zhejiang Renben Group; Headworks: Zhejiang Shaoxing Speda | |||
Performance Parameters of Fan Coil Units (GB/19232 2003) | ||||||||||||||||||||||
| Model Performance | FP--34 | FP-51F | FP-68 | FP-85 | FP-102 | FP-136 | FP-170 | FP-204 | FP-238 | |||||||||||||
| Rated Airflow m³/h | High | 340 | 510 | 680 | 850 | 1020 | 1360 | 1700 | 2040 | 2380 | ||||||||||||
| Zhōng (China) | 260 | 390 | 510 | 640 | 770 | 1020 | 1280 | 1530 | 1790 | |||||||||||||
| Low | 170 | 260 | 340 | 430 | 510 | 680 | 850 | 1020 | 1190 | |||||||||||||
| Rated Cooling Capacity Kw Kcalh | H | 1.98 | 2.8 | 3.87 | 4.58 | 5.42 | 7.38 | 9.08 | 11.1 | 12.9 | ||||||||||||
| H | 1702 | 2408 | 3328 | 3938 | 466 | 6346 | 7808 | 9546 | 11094 | |||||||||||||
| Guo Ding Heat Kw Kcalh | H | 3.39 | 4.5 | 6.35 | 7.45 | 9.22 | 12.4 | 16.3 | 19.5 | 20.2 | ||||||||||||
| H | 2915 | 3870 | 5460 | 6407 | 7930 | 10665 | 14020 | 16770 | 17370 | |||||||||||||
| Input Power W | 12Pa | H | 37 | 52 | 62 | 76 | 96 | 134 | 152 | 189 | 228 | |||||||||||
| 30Pa | H | 44 | 59 | 72 | 87 | 108 | 156 | 174 | 212 | 253 | ||||||||||||
| 50Pa | H | 49 | 66 | 84 | 100 | 118 | 174 | 210 | 250 | 300 | ||||||||||||
| Noise (dB) | 12Pa | H | 37 | 39 | 41 | 43 | 45 | 46 | 48 | 50 | 52 | |||||||||||
| 30Pa | H | 40 | 42 | 44 | 46 | 47 | 48 | 50 | 52 | 54 | ||||||||||||
| 50Pa | H | 42 | 44 | 46 | 47 | 49 | 50 | 52 | 54 | 56 | ||||||||||||
| Flow Rate: kg/h | 350 | 510 | 660 | 800 | 980 | 1280 | 1600 | 1920 | 2230 | |||||||||||||
| Water Resistance/Ka | 30 | 3 | 30 | 30 | 40 | 40 | 40 | 40 | 50 | |||||||||||||
| Number of fans | 1 | 2 | 3 | 4 | ||||||||||||||||||
| Weight: kg | WA | 7 | 18 | 1 | 22 | 2 | 39 | 49 | 52 | |||||||||||||
| Reversible blower box | 20 | 22 | 23 | 27 | 30 | 44 | 48 | 54 | 58 | |||||||||||||
| Inlet and outlet water connections | 3/4 NPT Thread | |||||||||||||||||||||
| Condensate Pipe | 3/4" male thread | |||||||||||||||||||||
| Power Supply | 220V/50HZ | |||||||||||||||||||||