Corrosion and Explosion-Proof Air Conditioner

平台认证
  • Unit Price

    Negotiable

  • Brand

    Tongteng

  • MOQ

Contact
Leave Msg

Platform Service

Supplier Verified



河南同腾防爆电器有限公司

VIP   标王第4年
资料通过中商114认证

Product Details

Specs

Gallery

  • Brand:

    Tongteng

  • Unit Price:

    Negotiable

  • MOQ:

  • Total:

    0

  • Address:

    HenanNanyang

  • Delivery:

    3days

  • View More

Description

Explosion-proof and corrosion-resistant air conditioning applicable environments:




Suitable for explosive gas environments in zones 1 and 2.




Suitable for II A, II B, II C explosive gas environments.




◆ Suitable for environments with temperature categories T1 to T4.




◆ Suitable for flammable and explosive areas prone to acidic and alkaline corrosion.




Commonly used in shipbuilding and dock facilities.




Explosion-proof and corrosion-resistant air conditioning product features:




★Outdoor and indoor units are corrosion-resistant (with the outdoor unit generally being the default), and the evaporator and condenser are entirely composed of copper fins. Employing various corrosion-resistant technologies, the units significantly enhance anti-corrosion effectiveness, enabling normal operation in acidic and alkaline environments without shortening the product's lifespan, which is N times longer than that of conventional explosion-proof air conditioners. Additionally, it improves safety performance (the lifespan of different explosion-proof air conditioners in strong acidic or alkaline environments is roughly only a few months), significantly increasing the product's safety and lifespan.




◆ Explosion-proof air conditioners are available in two performance types: single-cooling and heating-cooling. They can be categorized into three structural forms: window-mounted, split-wall-mounted, and split-cabinet.




◆ Explosion-proof air conditioners are designed to meet the requirements of the GB 3836 series standards, based on renowned air conditioners, with special processing techniques and manufacturing methods for explosion-proof treatment; ◆ The pipeline connection and installation of explosion-proof air conditioners are the same as those of regular air conditioners, with electrical connections following the installation requirements of explosion-proof electrical equipment. First, the power source is introduced to the explosion-proof control box, and then separately to the indoor and outdoor units from the control box.




The explosion-proof control box is equipped with a power switch.




◆ We can provide explosion-proof treatment for special air conditioning equipment on-site as per customer requirements. For instance, this includes large-scale chilled water units, refrigeration units, central air conditioning systems, and air conditioning equipment with special installation forms. We will design and manufacture the solution, submit it for customer review, and upon request, we can apply for an explosion-proof testing center to conduct on-site product explosion-proof performance testing.




◆ All explosion-proof air conditioners are supplied with a complete set of product technical documentation and installation/user manuals. Users must strictly follow the instructions in the manual for installation and use.




The product features a compact structure, stylish appearance, and easy installation and maintenance.




Energy-efficient, low noise;




◆ Steel pipe or cable wiring.




★ The entire unit employs ultra-low voltage technology for intrinsic safety circuit isolation, manufactured through special processes and explosion-proof treatments. The design and manufacturing of the product strictly adhere to relevant standards.




GB 3836.1-2000 "Electrical Equipment for Explosive Gas Atmospheres - Part 1: General Requirements"




GB 3836.2-2000 Electrical Equipment for Explosive Gas Atmospheres - Part 2: Flameproof "d" Type




GB 3836.3-2000 Electrical Equipment for Explosive Gas Atmospheres – Part 3: Increased Safety “e”




GB 3836.4-2000 "Electrical Equipment for Explosive Gas Atmospheres - Part 4: Intrinsic Safety 'i'"




GB 3836.9-2006 Electrical Equipment for Explosive Gas Atmospheres - Part 9: Encapsulation Type “m”




★The product surface is equipped with surface temperature limit protection technology, anti-static technology, and various safety protection measures.




★Wide voltage design for unstable outdoor power sources, voltage: 220V/50Hz, 220V/60Hz, 110V/50Hz




★ Explosion-proof Mark: ExdemnAib[ib]‖BT4, Exdmib‖CT4.


Disclaimer:Info provided by user, user liable for authenticity, accuracy & legality. Zhongshang114 assumes no liability.

Tip:Confirm supplier qualification & quality before purchase to avoid risks.

Unit Price Negotiable
Inquiry None
Delivery HenanNanyang3dayswithin
Brand Tongteng
Features Cool and warm
Structure Complete Unit Explosion Proof
Cooling/Heating Rated Power 8.5 kW / 2.1 kW
Expiry Long Valid
Update 2023-02-25 17:48
Gallery

Henan Tongteng Explosion-Proof Electrical Appliances Co., Ltd.Published byCorrosion and Explosion-Proof Air ConditionerGallery Lib

Contact Merchant



Join

Successful Enterprise Join, Enjoy Multiple Privileges

Join Hotline:4006299930

Please scan with mobile phone

Customer Service

Service Hotline:4006299930

Official Account

WeChat Official Account, Get Business Opportunities

Scan to follow WeChat

Top