Product Description
Integrated pump station, as the name implies, is a device that combines a pump, piping, and electrical equipment into one. The integrated pump station is an upgraded version of the traditional pump station, which no longer meets the needs of urban economic construction and development. Compared to the traditional pump station, it has many advantages, such as smaller land occupation, lower noise, easy handling, and strong predictable performance.

Product Advantages
1. Compact in size yet boasts excellent usable volume; high degree of integration, truly integrated.
2. The integrated pump station cylinder is made of advanced corrosion-resistant material, reinforced with glass fiber reinforced plastic (GFRP) mechanical winding or lined with special steel and coated with GFRP.
3. The pump sump is designed with CFD fluid dynamics, featuring good flow state, no clogging, and self-cleaning capabilities.
4. Reliable quality, leak-proof, non-polluting to the environment; lightweight, low cost.
5. Equipped with high-quality, high-performance submersible sewage pumps, widely-used sensors continuously monitor the pump's operation, significantly reducing maintenance costs.
6. High degree of automation integration, allowing remote monitoring and management, as well as mobile inspection capabilities. It also supports unlimited remote data transmission and automatic generation of operational reports.
7. Safe Usage: Its scientific design and configuration greatly reduces the generation of highly toxic and malodorous gases, protecting the environment.
8. Fully buried installation with no impact on the surrounding environment or landscape after installation.
9. Short installation period, saving most costs; maintenance is time and labor-saving.
10. One-time investment, with low long-term operation costs, significant energy-saving benefits, and the ability to be re-lifted and re-used for secondary landfilling in case of demolition or land occupation.
11. Fully customizable, each time can design pump stations with varying diameters and heights for in/out water pipe locations based on different projects, to meet the needs of various locations.

Operations and Maintenance
1. After maintenance, the pump's flow rate should not be less than 90% of the designed flow rate; its unit efficiency should not be less than 90% of the original unit efficiency. The integrity rate of the pump station units should reach over 90%; during flood season, the operational rate of the pump station units should reach over 98%.
2. Equipment and pipe fittings should be subjected to rust removal and painting treatments every two years.
3. Integrated pumping stations and their auxiliary facilities should be cleaned and maintained regularly. Any damage should be repaired immediately. They should be refreshed every 3 years.
4. When entering the well shaft of an integrated pump station for maintenance, safety protection measures must be in place. Respiratory protection equipment must be inspected before use and deemed fit for use before it can be utilized.
5. Pumps should be regularly cleaned and desilted based on the inspection results of the pump station.
6. The integrated pumping station should have complete operation and maintenance records.
7. Safety requirements for pipeline maintenance and inspection should comply with the provisions of the current industry standard "Technical Code for Safety Maintenance of Drainage Pipelines" CJJ6.

Equipment Function
The construction of sponge cities marks a significant starting point for the transformation of China's urban development, representing a new model for urban development and operation. It requires not only the establishment of an ecological governance concept during urbanization but also a series of plans, systems, and policies to ensure the implementation of this concept, as well as the overall investment in green infrastructure and the long-term maintenance and upgrading of facilities. Over the past decade, some American cities have attempted a range of innovative stormwater management systems and policies, from stormwater fees to the creation of stormwater credit markets. These explorations can provide valuable references for China's cities in building related policies and innovative infrastructure investment and financing mechanisms for sponge cities.
After-Sales Commitment
1. Quality Assurance: Our company guarantees that all products are in the original factory packaging, accompanied by technical documents (including product catalogs, user manuals, certificates of conformity, and usage guides).
2. Warranty: All products and accessories provided by our company come with a 2-year on-site warranty, including on-site service, without the need for the user to send them in for repair. We also offer lifetime technical support and maintenance. Consumables during the equipment's use are supplied at market-friendly discounted prices, and no charges for on-site services are applied.
3. Response Time: Reach the repair site in the provincial capital within 6 hours and be ready for inspection; in other cities, arrive at the repair site within 12 hours and be ready for inspection; repairs completed within 24 hours.
4. Service Operating Hours: We provide round-the-clock service for all products we supply, ensuring 24 hours a day, 7 days a week.