Tianjin Logan KeXing Technology Co., Ltd.VIP

颗粒计数器, 油液污染度检测仪,液体颗粒度检测仪等
Enter Shop

Supply Logan Kexing KT-2A Desktop Liquid Particle Size Analyzer

平台认证
  • Unit Price

    Negotiable

  • Brand

    Logan Sinovac

  • MOQ

    1Set

Contact
Leave Msg

Platform Service

Supplier Verified



天津市罗根科兴科技有限公司

VIP   数字营销第4年
资料通过中商114认证

Product Details

Specs

Gallery

  • Brand:

    Logan Sinovac

  • Unit Price:

    Negotiable

  • MOQ:

    MOQ1Set

  • Total:

    0Set

  • Address:

    Tianjin

  • Delivery:

    Pre-sale, after payment15days

  • View More

Description

    Logan Kexing KT-2A Desktop Liquid Particle Size Analyzer | Particle Counter

Developed based on the principle of photoresist (light blocking) method, used for measuring the size and quantity of solid particles in liquids.,Widely applicable in the aviation industryAerospaceAviation engines, heavy industry machinery.In the fields of power, oil, petrochemicals, transportation, ports, metallurgy, machinery, and automotive manufacturing, solid particle contamination testing is conducted on fluids such as hydraulic oil, lubricating oil, rock oil, transformer oil (insulating oil), turbine oil, gear oil, engine oil, aviation kerosene, and water-based hydraulic oil.And regardingWater-based samples, chemical reagents,Organic liquids and polymer solutions for insoluble particle treatmentSampleInspection.

Performance Features:

Utilizing the principle of photoresist (light shielding) method, it boasts advantages such as fast detection speed, strong anti-interference capability, high accuracy, and good repeatability.

High-precision sensors ensure high resolution and accuracy.

Precision plug-type sampling system, ensuring consistent sampling speed and precise volumeSureControl.

Please provide the Chinese content to be translated into American English./Vacuum pressure vessel device for degassing samples and testing high viscosity samples.

5.6InchColor LCDScreen DisplayTouchScreenOperation.

Built-inNAS1638ISO4406-1999ISO4406-2007ISO4406-1987GB/T 14039-2002GJB420B-2006GJB420B-2015GJB420A-1996AS4059EAS4059FROCT17216-1971ROCT17216-2001JTS-005SAE749D-1963NAS1638/ISO4406Particle contamination grade standards available, and can be fitted with required standards upon customer request.

Built-in"Customized" standards, with optional spacing0.01μmCan be set to any particle size dimension.9900Particle size, for easy particle size analysis.

Can store up to four calibration curves simultaneously (latex ball calibration curve,ACFTDCalibration CurveISOMTDCalibration curvesGOSTCalibration curve), and can be easily switched, reducing conversion errors.

Test data storage function for easy archiving, retrieval, and analysis of test data.

Built-in printer, capable of directly printing out test reports.

Built-in Chinese input method, enabling Chinese annotations on inspection reports.

RS232Interface and powerful data functionalitiesHarvestSoftware for external computers to process detection dataLabelingStorage,SearchGeneratePDFInspection reports, etc.

Features magnetic stirring for even particle distribution.

The pressure pump is equipped with four-stage gas filtration and a water purification unit, preventing environmental air from contaminating the samples.

 

Technical Specifications

1.Light    Semiconductor Laser

2.Scope of Inspection:0.8μm600μm(Subject to the selected sensor)

       3.Particle size range:1100μmISO4402) or470μm(c) GB/T18854ISO11171

       4.Spirit Sensitivity Degree:0.8μmISO4402)or3μmc)   GB/T18854ISO11171

5.Inspection Channel:16Pieces, with intervals0.01μmAny particle size can be set

6.Sample Volume:0.2100mlComma spacing0.1ml

7.Relative Error of Sample Volume: Better than ±0.5

8.Testing Speed:580mL/min(Default)15mL/min

9.Cleaning Speed:580mL/minDefault15mL/min

10.Please provide the Chinese content to be translated. Identify Power: Superior10%(GBT18854-2002ISO11171)

11.Overlap Error Limit:1200040000Grain/mL(Subject to the selected sensor)

12.Particle count repeatability:RSD<2%

13.Particle Count Relative Error: ±5%

14.Pressure Vessel Negative Pressure<-0.08MPa

15.Positive pressure in the pressure chamber:<1MPa

16.Test Sample Viscosity: ≤650cSt

17.Inspect Sample Temperature:0℃~80

18.Operating Temperature:0℃~60

19.Storage Temperature:-30℃~80

20.Supply    Electricity100245V,4962Hz

21.Dimensions: Main  Machine 430×320×590mm     Air Pump 330×266×255mm

21.Instrument Net Weight: Main Unit30kgPressure Pump10kg

 

 


Disclaimer:Info provided by user, user liable for authenticity, accuracy & legality. Zhongshang114 assumes no liability.

Tip:Confirm supplier qualification & quality before purchase to avoid risks.

Unit Price Negotiable
Inquiry None
Delivery TianjinPre-sale, after payment15dayswithin
Brand Logan Sinovac
Light Source Semiconductor Laser
Inspection Scope 0.8μm to 600μm
Particle size range 1 to 100 μm
Expiry Long Valid
Update 2023-04-15 10:28
Gallery

Tianjin Logan KeXing Technology Co., Ltd.Published bySupply Logan Kexing KT-2A Desktop Liquid Particle Size AnalyzerGallery Lib

Contact Merchant



Join

Successful Enterprise Join, Enjoy Multiple Privileges

Join Hotline:4006299930

Please scan with mobile phone

Customer Service

Service Hotline:4006299930

Official Account

WeChat Official Account, Get Business Opportunities

Scan to follow WeChat

Top