I. Overview
The complete system consists of a P3000 high-pressure pump, UV3000 detector, sample valve, solvent tray, chromatography column, and operating software; installation, debugging, and use are all very simple.
2. The P3000 High-pressure Infusion Pump is a high-precision infusion pump system controlled by a single-chip microcomputer, with CPLD technology at its core. The all-digital frequency generator system, newly designed motor drive system, and user-friendly human-machine interface make operation very convenient. The newly designed pump head and single-valve design concept ensure the accuracy and repeatability of infusion under various conditions.
3. The UV3000 is a spectrophotometric detector that is compatible with any infusion pump, widely used in fields such as chemical analysis, pesticide, pharmaceutical, and chemical industries. It incorporates a fully digital and highly integrated design concept, significantly reducing instrument noise. Based on digital signal transmission and processing, the detector's signals can be directly input into the computer's serial port for collection, completely eliminating the need for traditional data acquisition cards!
II. Key Features
P3000 Series High-Pressure Analytical/Semi-Preparative Pump
Syringe method: Double plunger reciprocating pump, double plunger suction.
Display 320240-dot matrix large screen LCD display, blue backlit
System protection with slow start-up, stop, adjustable pressure, and automatic user data storage
System Connection 1/8" Pipe Connection
Control Independent Mode - Set all working parameters via the front panel buttons. Operate at high...
During pressure gradient mode, one pump serves as the main pump, controlling other pumps of the same model.
Infusion pumps, with gradient curves on the screen for adjusting the achieved gradient mode
Verify.
Serial Port Mode - Control high-pressure infusion pump via RS232 port
Power: 220V±10%, 50Hz, 400W
2. UV3000 UV/VIS Detector
Control Independent Mode via Front Panel Buttons
Serial Port Mode - Software controlled via RS232 port
Display 320240-inch large-screen LCD display with adjustable blue-backlight
Power Supply: 220V±10%, 50Hz, 60W
Dimensions and Weight: 398x149x267mm (Depth x Height x Width), 14kg
GLP Information: Total lighting hours, lighting counts, number of replacements, and product series numbers, etc.
Section 3: Technical Specifications of P3000 High-Pressure Infusion Pump
Infusion Method | Double-acting plunger pump, one main suction plunger. The other is an auxiliary plunger. |
Pump Head | Analytical: 10ml stainless steel/PEEK pump head / Semi-prep 50ml stainless steel/PEEK pump head |
Work pressure | Analytical: 42MPa stainless steel pump head / 30MPa PEEK pump head; Semi-preparative: 30MPa stainless steel pump head / 20MPa PEEK pump |
Flow Range | Analytical: 0.001-9.999 ml Semi-preparative: 0.01-49.99 ml |
Flow accuracy | RSD ≤ 0.5%(1ml/min) |
Traffic redundancy | RSD ≤ 0.1%(1ml/min) |
Display Screen | 320*240 dot matrix large screen LCD display with adjustable blue back light. |
System Protection | Slow start, stop below *low pressure 2ML. Both high and low pressures are adjustable, user data is automatically saved. |
System Connection | 1/16" pipeline connection |
Control System | Independent Mode: Set parameters using the full keyboard. When operating in the high-voltage gradient mode, one of the pumps acts as the main pump, controlling other identical high-pressure infusion pumps, and verifying the displayed gradient method through the gradient curve on the display. Serial Port Mode: Control the high-pressure infusion pump via the RS232 port. |
Note: Dimensions: 398*149*267mm, Weight: 10 kg, Power Supply: 220V ± 10%, 50Hz, 40W | |
Section 4: UV3000 Detector Technical Specifications
Wavelength Range/Accuracy | 190 — 700nm ± 2nm |
Wavelength repeatability | 0.4nm |
Light Source | Deuterium lamp (standard configuration); Tungsten lamp (replaceable) |
Light Source Control | Selectable light options, on/off settings |
Scanning feature | Halt scan; scan programmable, allowing the start and end points to be set, as well as the scan step size. |
Scope of Inspection | 0 — 2AU |
Baseline noise | 1.5*10—5 AU/h; Flow rate: 1 ml/min; Methyl alcohol/Water ratio: 80/20; Wavelength: 254 nm |
Baseline Drift | 4*10-4 AU/h; Flow rate: 1 ml/min; Methanol/Water Ratio: 80/20, Wavelength: 254 nm |
Time Constant | 0.1/0.2/0.5/1/2/5/10S |
Analog Signal | ± 0.1V ± 1.0V ± 10V |
Points Output | 16 adjustable levels |
Auto-zero | Full Range |
Control | Independent Mode: Set parameters via full keyboard. Serial Port Mode: Control the high-pressure infusion pump via RS232 port. |
Display Screen | 320*240 pixel matrix large screen LCD display with adjustable blue backlight. |
GLP | Total lighting time, number of lighting times. Number of light replacements and product series number, etc. |
Note: Dimensions: 398*149*267mm, Weight: 10 kg, Power Supply: 220V ± 10%, 50 Hz, 40W | |
V. Configuration Description:
Serial Number | Order Number | Description | Quantity |
1 | LC-3001 | P3000 High-pressure Infusion Pump | 1 |
2 | LC-3002 | UV3000 UV Detector/Flow Cell for Analysis | 1 |
3 | LC-3003 | Rehodyne Manual Sampling Valve 20UL Dosage Ring (USA) | 1 |
4 | LC-3004 | CXTH-3000 Chromatography Workstation | 1 |
5 | LC-3005 | Adjust C18 chromatographic column, 250*4.6, 10ul | 1 |
6 | LC-3006 | Debugging Toolkit | 1 |
7 | LC-3007 | Analytical Dynamic Mixer (Germany) Single-pump Type | |
8 | LC-3008 | Solvent Pallet | 1 |
9 | LC-3009 | Solvent Filters, Vacuum Pumps, Ultrasonic (Essential for First-Time Use) | Each 1 (Select) |