Key Performance Features
1. 96/72/60/48 circuits, 96/72/60/48 independent drawers, each circuit with a power of 6KW.
★2. Each output channel can be independently set as either a digital control direct switch or a direct bypass, with direct bypass control available for mechanical relays; the direct bypass function can operate independently without a decoder.
★3. Equipped with a 12-inch touch screen LCD display; allows for grouping and operation of individual output switches on the device, preventing strong current surges from simultaneous switching of all circuits; and can be controlled via Wi-Fi, local area network, or internet on the in-cabinet unit, smartphone, or computer.
★4. Each phase is independently equipped with dual full digital dual hot-swap dual CPU decoders, totaling 6 drawer-style decoders. Each decoder drawer can be easily interchanged for use, and supports hot swapping. The decoders feature the function to maintain the lighting field without going out when the dimming console is powered off or the signal line is disconnected.
5. Each output drawer is equipped with an air switch and a working indicator light, with the brightness of the indicator light varying with the output voltage.
6. Equipped with fiber optic network interface, compatible with international mainstream lighting network protocols; capable of receiving dual-channel DMX512 signal input.
★7. Equipped with an AI-driven LED matrix status feedback module, it can visually monitor the system's operational status, DMX signal input status, and power input status for normalcy; the DMX input signal status report can intelligently identify reversed positive and negative connections of the signal lines.
8. Three-phase four-wire power supply with TN-S protective grounding system; output circuits are sequentially phase-separated by number, easy to understand and visually, and automatically balanced.
9. A set of silicon cabinets is equipped with 4 independent noise-reduction cooling fans, all installed at the top. The main air intake channel for cooling is the upper gaps of each drawer, with air intake holes distributed on the front door. Noise level at 1m is <50db.
10. The main structure is a cold-rolled steel cabinet with a standing design, allowing doors on all four sides, with a lock on the front; all drawers are made of aluminum or aluminum alloy materials.
★11. Equipped with three patented artificial intelligence technologies, including phase failure error reporting, information reporting, and protection system. It can immediately report not only during phase loss, neutral wire disconnection, or incorrect wiring of neutral and live wires but also accurately identify the cause of the error (phase loss or incorrect wiring) and pinpoint which phase is affected. Additionally, it can immediately cut off the output to ensure that equipment such as lighting, audio, and large screens are not damaged.
12. Products undergo inspection by the China Inspection and Certification Group.
13. The product has passed the CE certification.
Main Technical Parameters
Power supply: Three-phase four-wire system, 380V/220V ±10%, 50Hz
TN-S Protective Grounding System
Control Signal: DMX-512
Power: 96/72/60/48 x 6 kW/phase
Product Dimensions:
96th Route: 600×750×2100mm
72-way: 600×750×1650mm
60-way: 600×750×1650mm
48-way: 600×750×1450mm
Description: Not all products are equipped with the aforementioned features; the specifics are subject to the terms of the contract.