The training tower shall meet the following requirements:
One, the training tower should be located near the end of the training field with a reserved runway, and a sand pit of 1.5 meters in front of the tower.
The training tower should have at least four floors, and in cities with a high number of high-rise buildings, the number of floors may be appropriately increased.
Three, the training tower's front windows on each floor must have no fewer than two, with a width between the windows (and the wall) of 1.0 meter.
Four, the training tower window dimensions are 1.2m x 1.8m, the window must be no less than 0.65m from the tower edge, the window sill width is 0.35m, the sill board thickness is 0.05m (protruding 5cm from the tower wall), the height from each window sill to the floor of that level is 0.8m, the height of each level is 3.5m, and an internal staircase with a clear width of no less than 0.7m should be provided, with a handrail tube diameter of no less than 0.026m.
Five, an unobstructed platform not less than 1.5 meters wide should be set on the inside of each floor of the training tower, with a floorboard at the top level.
Six, it is advisable to set up an outdoor fire escape ladder on the training tower. The ladder should lead to the top of the tower and ideally be set at a height of 3 meters from the ground, with a width not less than 50 centimeters. Training Tower Description: 1. Mainly composed of (1) simulated windows, (2) floor partitions, (3) rear frames, (4) observation and command platform frames, and the main steel structural frame. Simulated windows are installed at the front of the tower (customized with a certain number of floors and windows as needed), and floor partitions (steel plates) are placed between the upper and lower adjacent simulated windows. 2. A rear frame corresponding to the simulated windows is located below the rear of the tower. 3. The simulated windows, floor partitions, rear frames, and main frame are connected together with bolts. 4. Safety ladders connect between each floor. 5. The upper part of the tower is equipped with an observation and command platform.
Seven: Training towers typically undergo anti-corrosion treatment with spray painting, in a military green color. Alternatively, camouflage patterns or galvanizing may be applied.
Section 8: Our steel structure fire training towers are fully functional, featuring detachable and removable designs, unrestricted by geography, terrain, or land plots. Made with assembled components, they offer low cost and high recyclability, helping to save expenses and achieve twice the results with half the effort. Welcome all fire departments to place orders for our fire training towers.