详情描述
CUT-2012AType12ChannelFully Automatic Tube and Bar Material Production LineElectrostatic UltrasonicInspection System
System Overview:
CUT-2012AType12Automatic Channel Full-Length Bar and RodEddy CurrentUltrasonic Inspection SystemLeveragingPLCProgrammable Logic Controllers for speed encoders, photoelectric sensors,Eddy currentUltrasonic flaw detection instrument signal acquisition, computation, and control.Pipe and bar materialsOffline, variable speed ultrasonic flaw detection processPlease provide the Chinese content to be translated.A variety of required automatic control functions。
The systemUtilizing DC speed control technology and power module control technology to achieve stepless speed regulation of the conveyor roller, which can avoid the high-frequency random interference signals generated by conventional AC variable-frequency inverters.EnablesField test results are consistent and reliable.。
The systemFeatures various settings, adjustments, saving, and recalling functions for the parameters required for ultrasonic automatic flaw detection.WaitPractical features with easy on-site parameter adjustment and high detection efficiency。
The systemMeet the requirements for detecting defects on the inner and outer walls during the variable speed inspection process.,Requirement for automated sorting and marking.
Feature Highlights:
Possesses Adaptable to various testing requirements for different metals, wires, etc., and featuring a fully digital design, it allows for the establishment of multiple standard testing programs or expert systems within the instrument, facilitating easy access for users when changing product specifications. It is equipped with input/output control interfaces for convenient connection to various equipment on-site and for synchronous operation, forming a highly automated integrated system.
Instrument Parameters:
Channel Count | 12 |
Total Gain | 80dBStep Increment0.1dB |
Work Method | Single probe transmission/reception, or dual probe transmission/reception |
Sensitivity Margin | ≥50dB |
Resolution | ≥26dB |
Dynamic Range | ≥30dB |
Scanning Range (Steel Longitudinal Waves) | 0~5000mm |
Frequency Range | 0.5~15MHz |
Repetition Frequency | 500Hz~10KHzAdjustable |
Vertical Linear | ≤5% |
Horizontal Linear | ≤1% |
Gate Setting | Per channel setting3A gate, an alarm gate, a tracking gate, and a self-locking gate |
Time Delay (Braking) Alarm | Delay time0.5~10SIncrement0.1S |
Inspection Conditions and Waveform Storage | Unlimited quantity, available for conditional access, waveform playback, waveform communication, waveform printing |
Work Environment:
Operating Temperature:-15~55℃
Storage Temperature:-20~60℃
Relative Humidity: Not exceeding85%
Working Voltage:AC380±15V
Inspection Corner:
Inspection Corner: