- AllProduct Category
-
Herbal Sulfur Dioxide Analyzer
Carbonized Monolithic Muffle Furnace
Nitrogen Generator
Oxidation Blowing Instrument
Condensation Recirculation Extractor
Concentrated Acid Neutralizer
Liquid-Liquid Extraction Apparatus
Intelligent Integrated Distillation Unit
COD Dissolver


详情描述
WithGB5009.34-2022 "Determination of Sulfur Dioxide in Food"The new national standard has been issued, and the detection methods for sulfur dioxide in food and traditional Chinese medicinal materials in the "Chinese Pharmacopoeia" are roughly the same. Fengxian Yide Instrument has developed based on the new national standard and pharmacopoeia methods,FX-3L460 Model, FX-3Z660 Model, FX-4W680 ModelSpecialized testing equipment.
Product Features
Heating Method:Can simultaneously perform heating, distillation reflux, cooling, nitrogen blow control, magnetic stirring, and collection tasks.
* Heating Method: Automatic far-infrared ceramic heating management system.Energy-efficient and environmentally friendly, with excellent waterproof performance and resistance to acidic and alkaline corrosion.
Cooling Method: Integrated design with an internal compressor in the main unit, automatically completing the internal circulation of cooling water without the need for an external chilled water unit.
Condenser Tube Design: Standardized回流Condenser Tube for National Standards.
Control System: Automatic temperature rise technology, featuring adjustable modes for gentle boiling and full boiling heating; automatic timing from 0 to 999 minutes.
Reagent Addition: Optional high-precision reagent dosing pump for automatic addition of reagents; no manual operation required.
Nitrogen Control: Rotameter controlled, range: 200-2000ml/min.
* Sample Quantity:One can produce 1-4/6 sets of samples at a time, each channel can be controlled independently.
Comparison of New and Old National Standards for the Determination of Sulfur Dioxide in Food (Method) | ||
GB5009.34-2016 | GB5009.34-2022 (New National Standard) | |
Inspection Method |
Titration method | Titration method changed to: Acid-Base Titration, with the addition of Spectrophotometry Method, and the Third Method Ion Chromatography. |
Scope of Inspection | This standard specifies the method for determining total sulfur dioxide in foods such as candied fruits, dried vegetables, rice noodles, vermicelli, sugar, edible mushrooms, and wine. | French Acid-Base Titration Method, suitable for the determination of sulfur dioxide in food. |
Sample Preparation | 5g uniform sample (up to 0.001g, sampling quantity varies with the content level); liquid samples can be directly aspirated 5.00mL to 10.00mL; add 250ml of water; add 10ml of hydrochloric acid. | Collect solid or semi-liquid samples20g to 100g (to 0.01g, sample size depends on content level); take 20mL (g) to 200mL (g) of liquid sample; add 20-500ml of water; add 10ml of 6mol/L hydrochloric acid. |
Is Nitrogen Filling Available for Distillation? | No | Nitrogen Filling and Distillation, Flow Rate:0.2-2.0L/min |
Absorbent liquid | 25mL Lead Acetate Absorption Solution | 50mL 3% Hydrogen Peroxide Solution (French) |
Distillation Method | Gather200ml distillate, re-distill for 1 minute, and rinse the insertion device into the absorbent liquid with a small amount of distilled water. | The solution inside the flask is heated to boiling and maintained at a gentle boil.1.5h。 |
Titration method | Add sequentially to the removed iodine bottle10mL hydrochloric acid, 1mL starch indicator solution; mix well and titrate with standard iodine solution until the solution turns blue and remains so for 30 seconds. Perform a blank test simultaneously. | Cool the absorbent solution and shake well before adding3 drops of 2.5 mg/mL methyl red ethanol solution indicator, titrated with a sodium hydroxide standard solution (0.01 mol/L) to a yellow color that does not fade within 20 seconds, while performing a blank test concurrently. |
Detection Limit vs. Quantitation Limit | When picking upFor 5G solid samples, the method's limit of detection (LOD) is 3.0 mg/kg, and the limit of quantitation (LOQ) is 10.0 mg/kg; for 10 mL liquid samples, the LOD is 1.5 mg/L, and the LOQ is 5.0 mg/L. | When usingAt a 0.01mol/L sodium hydroxide titrant, for solid or semi-liquid samples weighing 35g, the detection limit is 1mg/kg and the quantification limit is 10mg/kg; for liquid samples of 50mL (g), the detection limit is 1mg/L (mg/kg) and the quantification limit is 6mg/L (mg/kg). |
Product Recommended Model | FX-3L460 Model | |
询价单