- AllProduct Category
-
Lab Wastewater Treatment Equipment
Lab Wastewater Treatment Equipment
Ultra-Pure Water Equipment
Membrane Separation Equipment
Pure Water Equipment
Low-Temperature Evaporator
Ultra-Pure Water System
Integrated Wastewater Treatment Equipment
Reverse Osmosis Equipment
Pure Water Equipment
Ceramic Membrane Equipment


详情描述
Quankun Environmental - School Laboratory Wastewater Treatment Equipment - Pharmaceutical Synthesis Wastewater Treatment Equipment
The ammonia-nitrogen concentration in the treated wastewater from our laboratory equipment is below 15 mg/L, meeting the first-class discharge standards. It is a system that combines simplicity in process, cost-effectiveness, mature technology, ease of control, and no secondary pollution. Traditional ammonia-nitrogen stripping releases into the atmosphere with air, which can still cause secondary pollution. Our company has installed an absorption tower after the ammonia-nitrogen stripping tower, ensuring that the air emitted into the atmosphere is purified and pollution-free.

Process Description:
Wastewater is collected and homogenized in a collecting tank before flowing into a neutralization reaction tank. Quantitative acid (or alkali) solutions are added according to the water quality characteristics to initiate neutralization reactions. The neutralized wastewater is then pumped to a filtration tank for filtration. During this process, a定量 amount of净水剂 solution is also introduced to facilitate flocculation reactions in the wastewater, enhancing filtration efficiency. The filtered clean water is sterilized by an ultraviolet sterilizer and then flows into a biological activated carbon tank, further trapping and adsorbing fine pollutants before being discharged directly into the urban sewage network.


Product Features:
1. Treat wastewater inorganic pollutants with neutralization coagulation, natural sedimentation, fine fiber filtration, and activated carbon adsorption technologies.
2. Features around-the-clock, fully automatic operation; no need for dedicated on-site staff.
3. Accurately control the dosage with a pH meter and imported metering pump.
4. User-friendly, stable operation, long service life, low maintenance costs.
5. Small land area required, can be installed indoors or outdoors as needed.
6. Tailored design and manufacturing services are available to meet various customer requirements.

Process Features:
1. Utilize neutralization precipitation, composite disinfection, UV ultraviolet light sterilization, ozone oxidation, and multi-media filtration to treat various pollutants in wastewater.
2. Equipped with a PLC programmable intelligent control system and a human-machine interface operation screen: LCD Chinese display of all monitoring parameters such as equipment start/stop, flushing, and waste discharge functions; shows the operating status of each unit, automatically records and manages historical water quality data and analysis. Features human-machine dialogue, clock and language setting functions. The system automatically detects upon startup, and automatically processes wastewater. Depending on the composition and concentration of different wastewaters, the control system automatically calculates and proportionally dispenses chemicals.
3. Utilize pH meters and imported metering pumps to precisely control the dosing amount, equipped with liquid level control and water level alarm systems.
4. The oxygenator used ensures thorough gas-water contact and complete reaction.
5. User-friendly, stable operation, long service life, low running and maintenance costs
6. Compact in size, suitable for installation indoors or outdoors as needed.
7. Custom design and manufacturing services available to meet various customer requirements.
8. Features Automatic Protection: Automatic leakage and electric shock protection, automatic high and low voltage protection, no wastewater protection, liquid level protection for each treatment unit, electrical equipment overload protection, and electrical circuit overload protection.
9. Cleaning Function: The system automatically cleans the necessary components at scheduled intervals.
10. Environmentally Friendly: Utilizes low-noise double-silenced motor and anti-corrosion pump; employs closed-loop treatment throughout, free of odors and leaks, and prevents secondary environmental pollution from waste sludge, wastewater, and exhaust gases.
11. Scheduled On/Off Function: Can be set to automatically turn on and off at specified times for morning and evening, eliminating the need for operators to manually turn the equipment on and off in the equipment room every morning and evening.

Quankun Environmental Protection - School Laboratory Wastewater Treatment Equipment - Pharmaceutical Synthesis Wastewater Treatment Equipment
Laboratory wastewater contains acids, alkalis, organic pollutants, heavy metal ions, pathogenic microorganisms, with a wide pH value range and high COD concentration. It is primarily categorized into three major types:
1. Organic Wastewater: Primarily derived from laboratory reagents and solvents.
2. Inorganic Wastewater: Main sources include acidic and alkaline reagents, heavy metal reagents.
3. Pathogenic Wastewater from Biological Sources: Primarily originates from microbial culture, blood biochemical tests, blood stations, disease control centers, etc.