Digital Resolution:0.01℃
TemperatureUniformity:±0.05℃
● Fully enclosed environmental-friendly refrigeration system using refrigerants in compliance with the Montreal Protocol.
● Temperature Control Function: Incorporates a first-generation integrated PID automatic temperature control program.Built-in accuracyPT100 Temperature Sensor AAAEquipped with a large, high-contrast LCD screen, featuring bilingual Chinese-English display, the digital resolution is:0.01°C, ensures precise and stable temperature control.
●Internal Circulation Function: Utilizes a heat-free centrifugal circulation pump to avoid the heat generated by traditional pumps affecting the bath's thermal field. The internal circulation system is designed for...PorousUDesign of Type Reflux Recirculation PrincipleAchieved turbulent and highly uniform flow and temperature fields within the groove body.
● Precision-machined front panel and desk top of the cabinetUniquePeople-orientedRRounded designStructure, availableAvoidOperations personnelAccidentally caught on a sharp edgePlease provide the Chinese content to be translated into American English.Hurt。
Safety Protection Device:
2. Equipped withUpper and Lower Temperature Alarm SettingsFeatures
4. Temperature Override Protection and Alarm Function
6. Multi-protection function for overheating and overcurrent of compressors
1.Optional extended external accessoriesPT100 temperature sensor, capable of real-time detection and control of the external system's temperature during the external circulation.
3.OptionalRS232 or RS485 communication interfaces, easy to connectSupervisor station, withModbusRTUCommunication Protocol.
5.Optional internal cooling tube within the slot for rapid cooling and control of the system's heat dissipation reaction.
7.Optional horizontal design with compact structure,Center of gravity reducedHigh stability and other characteristics.
XODCLow-temperature恒温槽Series Model and Parameter Comparison Table
Model
Recirculation Pump Flow(L/min)
XODC-0506
-5~100
±0.05
275×195×120
6
180×140
600
13
XODC--0510
-5~100
±0.05
275×195×180
10
180×140
900
13
XODC--0515
-5~100
±0.05
300×250×200
15
235×160
1500
13
XODC--0520
-5~100
±0.05
300×250×270
20
235×160
2000
13
XODC--0530
-5~100
±0.05
440×325×210
30
310×280
2700
13
XODC--0550
-5~100
±0.05
500×340×300
50
350×300
4000
13
XODC--05100
-5~100
±0.05
625×400×400
100
480×380
7000
13
XODC--1006
-10~100
±0.05
275×195×120
6
180×140
800
13
XODC--1010
-10~100
±0.05
275×195×180
10
180×140
1200
13
XODC--1015
-10~100
±0.05
300×250×200
15
235×160
1800
13
XODC--1020
-10~100
±0.05
300×250×270
20
235×160
2300
13
XODC--1030
-10~100
±0.05
440×325×210
30
310×280
3000
13
XODC--1050
-10~100
±0.05
500×340×300
50
350×300
4300
13
XODC--10100
-10~100
±0.05
625×400×400
100
480×380
7500
13
XODC--2006
-20~100
±0.05
275×195×120
6
180×140
1200
13
XODC--2010
-20~100
±0.05
275×195×180
10
180×140
1600
13
XODC--2015
-20~100
±0.05
300×250×200
15
235×160
2200
13
XODC--2020
-20~100
±0.05
300×250×270
20
235×160
2700
13
XODC--2030
-20~100
±0.05
440×325×210
30
310×280
3400
13
XODC--2050
-20~100
±0.05
500×340×300
50
350×300
4700
13
XODC--20100
-20~100
±0.05
625×400×400
100
480×380
7900
13
XODC--3006
-30~100
±0.05
275×195×120
6
180×140
1700
13
XODC--3010
-30~100
±0.05
275×195×180
10
180×140
2100
13
XODC--3015
-30~100
±0.05
300×250×200
15
235×160
2700
13
XODC--3020
-30~100
±0.05
300×250×270
20
235×160
3200
13
XODC--3030
-30~100
±0.05
440×325×210
30
310×280
3900
13
XODC--3050
-30~100
±0.05
500×340×300
50
350×300
5200
13
XODC--30100
-30~100
±0.05
625×400×400
100
480×380
8400
13
XODC--4006
-40~100
±0.05
275×195×120
6
180×140
2300
13
XODC--4010
-40~100
±0.05
275×195×180
10
180×140
2900
13
XODC--4015
-40~100
±0.05
300×250×200
15
235×160
3400
13
XODC--4020
-40~100
±0.05
300×250×270
20
235×160
3900
13
XODC--4030
-40~100
±0.05
440×325×210
30
310×280
4600
13
XODC--4050
-40~100
±0.05
500×340×300
50
350×300
5800
13
XODC--40100
-40~100
±0.05
625×400×400
100
480×380
9000
13
XODC--5006
-50~100
±0.05
275×195×120
6
180×140
2700
13
XODC--5010
-50~100
±0.05
275×195×180
10
180×140
3400
13
XODC--5015
-50~100
±0.05
300×250×200j
15
235×160
3900
13
XODC--5020
-50~100
±0.05
300×250×270
20
235×160
4500
13
XODC--5030
-50~100
±0.05
440×325×210
30
310×280
5200
13
XODC--5050
-50~100
±0.05
500×340×300
50
350×300
6400
13
XODC--50100
-50~100
±0.05
625×400×400
100
480×380
9800
13
XODC--6006
-60~100
±0.05
275×195×120
6
180×140
3500
13
XODC--6010
-60~100
±0.05
275×195×180
10
180×140
4200
13
XODC--6015
-60~100
±0.05
300×250×200
15
235×160
4700
13
XODC--6020
-60~100
±0.05
300×250×270
20
235×160
5300
13
XODC--6030
-60~100
±0.05
440×325×210
30
310×280
6000
13
XODC--6050
-60~100
±0.05
500×340×300
50
350×300
7200
13
XODC--60100
-60~100
±0.05
625×400×400
100
480×380
10600
13
Manufacturer's Friendly Reminder- Constant temperature bathSelection should consider the following factors::
2. Select a water bath with the appropriate capacity based on your specific needs. The correct calculation for the effective working volume is: the opening size of the working bath plus the depth of the bath, in millimeters.
4. Determine if an external circulation function is needed based on usage, and specify the required head of the external circulation.