Shandong Zhongjie Special Equipment Co., Ltd.VIP

中杰特装储罐主营:LNG储罐、LPG储罐、液氧储罐、化工设备等安装服务.
Enter Shop

Chongzuo Oxygen Cylinder, On-Site Installation

平台认证
  • Unit Price

    $10000.00/Tai

  • Brand

    Zhong Jie

  • MOQ

    1Tai

Contact
Leave Msg

Platform Service

Supplier Verified



山东中杰特种装备股份有限公司

VIP   数字营销第2年
资料通过中商114认证
  • Shandong
  • 于秋波 (Mr.)   业务经理
Category
  • No Category

Product Details

Specs

Gallery

  • Brand:

    Zhong Jie

  • Unit Price:

    $10000.00 / Tai

  • MOQ:

    MOQ1Tai

  • Total:

    9999Tai

  • Address:

    Shandong

  • Delivery:

    3days

  • View More

Description

Shandong Zhongjie Special Equipment (formerly Heze Boiler Factory Co., Ltd.) holds an A-grade boiler manufacturing license, an A2-grade pressure vessel manufacturing license, an A2-grade pressure vessel design license, a B-grade boiler installation license, and GB2/Class GC2 pressure pipeline installation licenses, as well as a mechanical and electrical equipment installation contracting qualification. It is a member of the China Boiler and Water Treatment Association, the China Chemical Equipment Association, and the Standing Committee of the Shandong Equipment Manufacturing Association. The company has also passed the ISO9001 Quality Management System, ISO14001 Environmental Management System, OHSAS18001 Occupational Health and Safety Management System certifications, and the American ASME/U2 certification.
The filling process for liquid nitrogen tanks typically includes the following steps:
Preparation: Ensure the storage tank and filling equipment are in good condition with no damage or leaks. Check that the insulation layer of the tank is intact and undamaged.
Safety Inspection: Check the tank and its surrounding environment for safety. Ensure there are no flammable materials or other hazardous items around the tank.
Connect equipment: Link the filling equipment to the storage tank. Ensure the connection is securely fastened and leak-free.
Prepare Liquid Nitrogen: Prepare for liquid nitrogen supply, ensuring the quality and purity meet the requirements.
Open valves: Follow the operational instructions of the filling equipment to gradually open the corresponding valves, allowing liquid nitrogen to flow from the supply source into the storage tank.
Regulate Flow: Adjust the flow control valve of the filling equipment as needed to control the inflow rate of liquid nitrogen. Ensure a moderate flow rate, avoiding too fast or too slow.
Monitor Liquid Level: Real-time monitoring of the liquid nitrogen level in the storage tank through a level gauge or other level monitoring device. Ensure that the liquid level remains within a safe range.
Stop Filling: Close the valve of the filling equipment when liquid nitrogen fills the tank or reaches the required level, halting the inflow of liquid nitrogen.
Disconnect: Disconnect the filling equipment from the storage tank, ensuring there are no leaks at the connection point.
Safety Inspection: Recheck the tank and its surrounding environment for safety, ensuring no leaks or other potential hazards.
Please note that the process described is for general reference only; the actual filling procedure may vary depending on the specific type of storage tank and filling equipment. When conducting filling operations for liquid nitrogen tanks, please adhere to the relevant operational specifications and safety requirements, and ensure that the operators are properly trained and skilled in safety procedures.
崇左氧气储罐
When selecting a liquid oxygen cylinder with a medical oxygen concentrator, several factors should be considered:
Requirement: First, determine the oxygen demand of the institution or individual. Select the appropriate oxygen concentrator model and specification based on the required oxygen flow rate and pressure.
Safety and Reliability: Ensure the chosen oxygen concentrator has high levels of safety and reliability. Opt for products that meet relevant standards and specifications, equipped with safety features such as over-pressure protection, leakage protection, and overload protection.
Operational ease: Choose an oxygen concentrator that is simple to operate and user-friendly. Consider the methods for adjusting oxygen flow and concentration, as well as the clarity and readability of the operating interface.
Quality and Reputation: Choose an oxygen concentrator with excellent quality and reliability. Refer to customer reviews, word-of-mouth, and certifications to select the product.
Maintenance and After-Sales Service: Familiarize yourself with the maintenance requirements and after-sales support for the oxygenator. Ensure timely access to repairs and technical assistance to guarantee the proper operation and maintenance of the oxygenator.
Cost-effectiveness: When considering the price, performance, and features of oxygenators, opt for products with a favorable cost-performance ratio. Select an oxygenator that suits your actual needs and budget.
Be mindful that when selecting liquid oxygen storage tanks with medical oxygen concentrators, adhere to relevant equipment procurement regulations and standards. It's advisable to consult with equipment suppliers or relevant institutions to ensure the chosen concentrator meets your needs and safety requirements.
崇左氧气储罐
During the use of low-temperature liquid storage tanks, the following points should be noted:
Protective Gear: When handling low-temperature liquid storage tanks, appropriate protective gear must be worn, including gloves, protective clothing, and non-slip shoes. This equipment can protect the skin from damage caused by low-temperature liquids.
Avoid direct contact: Low-temperature liquids can be very cold and cause chills. Therefore, it is essential to avoid direct contact with low-temperature liquids, especially with the skin. Use tools or utensils for handling, and prevent hands from coming into direct contact with low-temperature liquids.
Ventilation Requirements: In the operational area of low-temperature liquid storage tanks, adequate ventilation must be ensured to expel gases produced by the evaporation of low-temperature liquids. Maintain air circulation to avoid excessive oxygen concentration, and reduce the risk of fire and explosion.
Prevent Leaks: Regularly inspect low-temperature liquid storage tanks for leaks, and equip them with leak detectors and alarm systems. In case of a leak, take immediate action to control and repair it. Avoid the hazards of low-temperature liquid leaks to personnel and the environment.
Fire Prevention Measures: Low-temperature liquids have lower boiling and freezing points, making them more prone to fires. To prevent and contain fires, fire barriers and fire-resistant coatings should be installed around low-temperature liquid storage tanks.
Static Protection: Handling low-temperature liquids may generate static electricity, increasing the risk of sparks causing fires. Measures such as using static-conductive materials and anti-static equipment should be taken to reduce the accumulation and release of static electricity.
Regular inspections and maintenance: Conduct regular checks on the status of low-temperature liquid storage tanks and related equipment, including valves, pipes, pressure gauges, etc. Ensure the equipment is in perfect condition, and promptly repair or replace any damaged parts.
Waste Gas Treatment: During the process of using low-temperature liquids, waste gas is produced. Appropriate waste gas treatment measures must be taken to minimize environmental impact.
Above are the precautions to be noted when using low-temperature liquid storage tanks, ensuring operational safety and the normal operation of the tank. During operation, it should be strictly adhered to the relevant operational procedures and safety operation requirements, avoiding...
崇左氧气储罐
Tanks are specialized storage equipment that requires regular inspections and maintenance to ensure safe operation. Here are common tank inspection methods:
Appearance Inspection: Regularly inspect the tank's exterior for leaks, corrosion, deformation, cracks, and other issues. Pay special attention to the integrity of the tank's joints, welds, and valves.
Pressure Test: Conduct pressure tests to inspect the tank's sealing performance and pressure resistance. Use a pressure gauge or pressure sensor to perform pressure tests on the tank to ensure it can withstand the designed pressure.
Ultrasonic Testing: Ultrasonic testing can be used to detect corrosion, cracks, and other issues in storage tank walls. By scanning the tank with an ultrasonic probe instrument, potential defects and problems are detected.
Magnetic Particle Inspection: This method can be used to detect cracks in tank walls and the quality of welds. By applying magnetic particles to the tank surface and then using a magnetic particle inspection instrument to observe for any particle accumulation, one can determine if there are any cracks or welding issues.
Environmental Monitoring: Regularly conduct environmental monitoring around storage tanks, including gas concentration and temperature measurements, to ensure the safety of the surrounding environment.
Note that tank inspections should be conducted by a certified inspection agency or qualified inspectors. The frequency and methods of inspection should be determined based on the tank's usage, size, and relevant regulatory requirements. Regular inspections and maintenance can help identify potential issues early on, ensuring the safe operation of the tank.
Shandong Zhongjie Special Equipment, welcome customers to visit our factory for business talks.

Disclaimer:Info provided by user, user liable for authenticity, accuracy & legality. Zhongshang114 assumes no liability.

Tip:Confirm supplier qualification & quality before purchase to avoid risks.

Unit Price $10000.00 / Tai
Sales None
Delivery Shandong3dayswithin
Stock 9999TaiMOQ1Tai
Brand Zhong Jie
Structural form Vertical
Pressure 0.8 or 1.6 MPa
Type Oxygen, Nitrogen, Argon Storage Vessel
Expiry Long Valid
Update 2025-06-30 13:52
Gallery

Shandong Zhongjie Special Equipment Co., Ltd.Published byChongzuo Oxygen Cylinder, On-Site InstallationGallery Lib

Contact Merchant



Join

Successful Enterprise Join, Enjoy Multiple Privileges

Join Hotline:4006299930

Please scan with mobile phone

Customer Service

Service Hotline:4006299930

Official Account

WeChat Official Account, Get Business Opportunities

Scan to follow WeChat

Top