Shandong Zhongjie Special Equipment Co., Ltd.VIP

中杰特装储罐主营:LNG储罐、LPG储罐、液氧储罐、化工设备等安装服务.
Enter Shop

Xianyang Nitrogen Storage Tank - Trustworthy

平台认证
  • Unit Price

    $10000.00/Tai

  • Brand

    Zhong Jie

  • MOQ

    1Tai

Contact
Leave Msg

Platform Service

Supplier Verified



山东中杰特种装备股份有限公司

VIP   数字营销第2年
资料通过中商114认证
  • Shandong
  • 于秋波 (Mr.)   业务经理
Category
  • No Category

Product Details

Specs

Gallery

  • Brand:

    Zhong Jie

  • Unit Price:

    $10000.00 / Tai

  • MOQ:

    MOQ1Tai

  • Total:

    9999Tai

  • Address:

    Shandong

  • Delivery:

    3days

  • View More

Description

Shandong Zhongjie Special Equipment (formerly Heze Boiler Factory Co., Ltd.) holds an A-grade boiler manufacturing license, an A2-grade pressure vessel manufacturing license, an A2-grade pressure vessel design license, a B-grade boiler installation license, and GB2/Class, GC2/Class pressure pipeline installation licenses, as well as a qualification for electromechanical equipment installation contracting. It is a member of the China Boiler and Water Treatment Association, the China Chemical Equipment Association, and the理事 unit of the Shandong Equipment Manufacturing Association. The company has also passed the ISO9001 Quality Management System, ISO14001 Environmental Management System, OHSAS18001 Occupational Health and Safety Management System certifications, and the American ASME/U2 certification.
When selecting the support for a liquid argon tank, consider the following factors:
Load Capacity: The support must be capable of bearing the weight of the liquid argon tank. Select a support with adequate load capacity based on the tank's capacity and dimensions. Typically, the weight of the liquid argon tank is specified in the design specifications, allowing for the determination of the support's load capacity.
Stability: The support must provide sufficient stability to prevent the tank from tilting or swaying during use. The design of the support should consider the tank's center of gravity and its changes to ensure stable support.
Corrosion Resistance: Liquid argon is both low temperature and corrosive, so the material of the support should have excellent corrosion resistance to prevent corrosion and damage. Common support materials include stainless steel, aluminum alloy, etc.
Insulation: Liquid argon storage tanks generally require thermal insulation. The supports should possess certain insulation properties to reduce heat transfer and the evaporation of liquid argon. The design of the supports should take into account the installation and protection of the insulation layer.
Installation and Maintenance: The bracket should feature ease of installation and maintenance for convenient tank installation and daily maintenance operations.
When selecting the support for a liquid argon tank, it's advisable to consult with engineers or suppliers. Choose an appropriate support based on the specific tank requirements and usage environment. Additionally, adhere to relevant design specifications and safety standards to ensure the quality and reliability of the support.
咸阳氮气储罐
Maintenance and upkeep are crucial for ensuring the safety of low-temperature storage tanks. Here are some common maintenance measures:
Regular Inspections: Conduct regular inspections of low-temperature storage tanks, including checks on the exterior, internal structure, and anti-corrosion coatings. Look for cracks, corrosion, wear, and other issues, and promptly identify and repair potential safety hazards.
Cleaning and Deicing: Regularly clean the exterior surface and internal structure of the low-temperature storage tank to remove accumulated dirt and ice layers. The buildup of ice can lead to structural damage and corrosion; cleaning and deicing can extend the lifespan of the tank.
Level Monitoring: Regularly monitor the liquid level of low-temperature storage tanks to ensure it stays within the safe range. Excessive or insufficient levels can lead to overpressure or over-vacuum in the tank, increasing safety risks.
Leak Detection: Install a leak detection system to regularly check for leaks in low-temperature storage tanks. Leaks can lead to the release and evaporation of liquids or gases, increasing safety risks.
Corrosion Protection Measures: Implement appropriate corrosion protection measures, such as coating protection and corrosion-resistant coatings, to safeguard the metallic structure of low-temperature storage tanks from corrosion damage.
Emergency Fault Handling: Establish an emergency fault handling mechanism to promptly address and repair issues with low-temperature storage tanks, preventing accidents from occurring or escalating.
Training and Development: Train and develop operational and maintenance personnel to ensure they have the relevant knowledge and skills to correctly operate and maintain low-temperature storage tanks.
Note that maintenance should be tailored to the specific type of tank and operating conditions, adhering to relevant local laws, regulations, and standards. During maintenance, it is recommended to consult with engineers or guidance from relevant institutions to ensure the tank's safety and reliability.
咸阳氮气储罐
Liquid Oxygen Storage Tanks Feature the Following Safety Technical Characteristics:
High-pressure Vessel: Liquid Oxygen Storage Tanks are high-pressure vessels capable of withstanding high pressures. Their design and manufacturing must comply with relevant standards and regulations to ensure the tank's strength and sealing integrity.
Low-Temperature Storage: Liquid oxygen tanks are used for storing liquid oxygen, with operating temperatures typically around -183 degrees Celsius. The materials and insulation of the tanks must withstand low-temperature environments to prevent evaporation of the liquid oxygen and the penetration of external heat.
Fireproof Design: Liquid oxygen contains a high oxygen content, which is prone to cause fires. The design of liquid oxygen storage tanks must incorporate fireproof measures, such as installing firewalls and using fire-resistant coatings, to prevent fire outbreaks and spread.
Leak Control: Leaks in liquid oxygen tanks can lead to increased oxygen concentrations, heightening the risk of fires and explosions. Tanks must be equipped with leak detection and alarm systems to promptly detect and control leaks, and to implement appropriate emergency measures.
Static protection: The accumulation of static electricity in liquid oxygen tanks may cause sparks, increasing the risk of fire. Tanks must be equipped with static conductive materials and anti-static devices to reduce the accumulation and release of static electricity.
Safety valves and pressure control: Liquid oxygen storage tanks must be equipped with safety valves and pressure control devices to ensure the internal pressure of the tank remains within a safe range. When the pressure exceeds the set value, the safety valve will automatically release pressure to protect the tank's safety.
Routine inspections and maintenance: Liquid oxygen tanks require regular inspections
咸阳氮气储罐
The normal pressure range for liquid oxygen tanks typically falls between 2-5 bar. This range refers to the oxygen pressure inside the tank, which is necessary to maintain the liquid state of the oxygen. The design and manufacture of liquid oxygen tanks should comply with relevant standards and regulations to ensure the tank can safely withstand this pressure range under normal operating conditions. It should be noted that the pressure of the liquid oxygen tank is influenced by various factors, such as the temperature of the liquid oxygen, the tank's design, and materials. In actual use, the normal pressure range of the tank should be determined based on the specific tank design and usage requirements, and operations and maintenance should adhere to relevant laws and standards. Additionally, liquid oxygen tanks should be equipped with pressure control devices, such as pressure valves or relief devices, to ensure the internal pressure remains within a safe range. These devices can automatically release gas when the pressure exceeds the set value, protecting the tank's safety. Regular inspections and maintenance of these pressure control devices should be conducted to ensure they function properly during the use of the liquid oxygen tank.
Shandong Zhongjie Special Equipment, welcome customers to visit our factory for business discussions.

Disclaimer:Info provided by user, user liable for authenticity, accuracy & legality. Zhongshang114 assumes no liability.

Tip:Confirm supplier qualification & quality before purchase to avoid risks.

Unit Price $10000.00 / Tai
Sales None
Delivery Shandong3dayswithin
Stock 9999TaiMOQ1Tai
Brand Zhong Jie
Structural form Vertical
Pressure 0.8 or 1.6 MPa
Type Oxygen, Nitrogen, Argon Storage Vessel
Expiry Long Valid
Update 2025-06-30 09:56
Gallery

Shandong Zhongjie Special Equipment Co., Ltd.Published byXianyang Nitrogen Storage Tank - TrustworthyGallery Lib

Contact Merchant



Join

Successful Enterprise Join, Enjoy Multiple Privileges

Join Hotline:4006299930

Please scan with mobile phone

Customer Service

Service Hotline:4006299930

Official Account

WeChat Official Account, Get Business Opportunities

Scan to follow WeChat

Top