Shandong Zhongjie Special Equipment (formerly Heze Boiler Factory Co., Ltd.) was established in 2001, located at No. 2218 Jinnan Road, Development Zone, Heze City. With a registered capital of 50 million yuan and total assets of 500 million yuan, the company has 7 business centers: boilers, deep-freezing containers, pressure vessels, central air conditioning, engineering installation, international trade, and Internet of Things. It has three factory sites on Jinnan Road, East Changjiang Road, and Bohai Road, covering a total area of 200,000 square meters, with the main workshop spanning 83,000 square meters. The company currently employs 710 people, including 247 engineering and technical staff and 82 intermediate-level technicians. In December 2016, it was recognized as a "High-tech Enterprise" by the Science and Technology Department. In June 2021, it was identified as a "Specialized and New Enterprise in Shandong Province" by the Ministry of Industry and Information Technology. In June 2022, it was recognized as a "Gazelle Enterprise in Shandong Province" and in August 2022, as a "Specialized and New Small Giant Enterprise" by the Ministry of Industry and Information Technology.
Prior to using the liquid oxygen tank, the following preparations must be made:
Safety Inspection: Ensure the tank and its surrounding environment are safe. Check for any damage, leaks, or other safety hazards on the tank. Make sure there are no flammable materials or other hazardous items in the vicinity of the tank.
Tank Preparation: Inspect the tank's exterior, including the shell, welds, valves, and fittings. Ensure there are no visible damages or corrosion. Check that the insulation layer is intact and undamaged.
Liquid Oxygen Filling: Utilize the liquid oxygen delivery equipment to fill the tank with liquid oxygen. Ensure that the flow rate and pressure of the liquid oxygen are maintained within a safe range during the filling process.
Pressure Control: Tanks should be equipped with pressure control devices to ensure the internal pressure of the tank remains within a safe range. Inspect and adjust the pressure control devices to ensure they are functioning properly.
Valve Operation: Check that the valves and connecting components of the storage tank are functioning properly. Ensure the valves operate smoothly and reliably. Adjust the opening and closing status of the valves as required.
Safety Equipment: Inspect the safety equipment around the storage tank, such as fire separation zones and alarm systems, to ensure they are functioning properly.
Operator Training: Ensure operators are knowledgeable in the safe operation of liquid oxygen tanks.
When selecting the support for a liquid argon tank, consider the following factors:
Load Capacity: The support must be capable of bearing the weight of the liquid argon tank. Select a support with adequate load capacity based on the tank's capacity and dimensions. Typically, the weight of the liquid argon tank is specified in the design specifications, which can be used to determine the support's load capacity.
Stability: The support must provide sufficient stability to ensure the tank does not tilt or sway during use. The design of the support should consider the tank's center of gravity and its changes to provide stable support.
Corrosion Resistance: Liquid argon has low temperature and corrosive properties. The support material should have good corrosion resistance to prevent corrosion and damage. Common support materials include stainless steel, aluminum alloys, etc.
Insulation: Liquid argon storage tanks generally require thermal insulation, with the supports having certain insulation properties to reduce heat transfer and evaporation of the liquid argon. The design of the supports should consider the installation and protection of the insulation layer.
Installation and Maintenance: The bracket should feature ease of installation and maintenance for the convenient assembly and daily maintenance of the storage tank.
When selecting the support base for liquid argon tanks, it's advisable to consult with engineers or suppliers. Choose the appropriate base according to the specific tank requirements and usage environment. Also, adhere to relevant design specifications and safety standards to ensure the quality and reliability of the base.
The testing and maintenance procedures for liquid oxygen storage tanks encompass the following aspects:
Appearance Inspection: Conduct regular visual inspections of liquid oxygen tanks, checking for corrosion, wear, and leakage on the tank surface, to ensure the tank's appearance remains intact.
Pressure Testing: Regularly conduct pressure tests on liquid oxygen storage tanks to assess their pressure resistance. Tests should be carried out in accordance with relevant standards and regulations, ensuring the tank can withstand the designed working pressure.
Leak Detection: Regularly conduct leak detection on liquid oxygen tanks, including using leak detection equipment to inspect the tanks to ensure good sealing performance and no leakage issues.
Cleaning and Coating Protection: Regularly clean and apply protective coatings to liquid oxygen tanks to prevent corrosion and oxidation. Use appropriate cleaning agents during cleaning and avoid substances that react with liquid oxygen. Protective coatings can include anti-corrosion coatings or protective coatings.
Regular Maintenance: Perform regular maintenance on liquid oxygen tanks, including inspections and replacement of seals, valves, safety devices, etc., to ensure proper operation and safety.
Safety Training and Operating Procedures: Conduct safety training for personnel using liquid oxygen tanks to ensure they are familiar with the safe operating procedures and precautions, in order to prevent operational errors and accidents.
Documentation and Record Management: Establish test and maintenance records for liquid oxygen storage tanks, including test results, maintenance logs, and inspection records, for traceability and management purposes.
It is essential that the testing and maintenance of liquid oxygen storage tanks be conducted by trained personnel, adhering to relevant safety operating procedures and standards. Additionally, a specific testing and maintenance plan should be developed based on the tank's condition and usage requirements, and executed accordingly.
When selecting low-temperature liquefied natural gas (LNG) storage tanks, the following factors should be considered:
Storage Tank Types: Common LNG storage tank types include vertical fixed-roof tanks, spherical tanks, and horizontal tanks. Select the appropriate tank type based on specific application requirements and site conditions.
Tank Capacity: The tank capacity is determined based on the storage requirements and projected usage of LNG. The capacity should meet the anticipated storage cycle and supply demands.
Material Selection: LNG tanks are typically made of low-temperature steel or nickel alloys to ensure corrosion resistance and strength in low-temperature environments. Select the appropriate material based on the tank's design pressure and temperature requirements.
Safety Performance: LNG tanks should possess excellent safety features, including seismic resistance, fire resistance, and leak control capabilities. The tanks must comply with relevant safety standards and regulations, such as API 620, EN 1473, etc.
Maintenance and Inspection: Consider the maintenance and inspection requirements of the tank, including internal cleaning, coating protection, corrosion prevention measures, etc. The tank design should facilitate maintenance and inspection operations to ensure long-term reliable operation.
Environmental Impact: When selecting LNG tanks, consider their impact on the surrounding environment. The layout and design of the tanks should comply with environmental protection requirements, minimizing noise, vibration, and gas emissions to reduce environmental impact.
Cost-effectiveness: Considering the investment cost, operating cost, and lifecycle cost of the tank, choose a tank with good cost-performance ratio.
需要注意的是,选型LNG储罐时应遵循相关的和地区的法规、标准和规范。此外,咨询的工程师或储罐制造商,以获取更详细和准确的选型建议。
ZJ Special Equipment adheres to the great vision of "realizing employees' dreams, creating customer value, and striving for the prosperity and strength of our motherland," and is dedicated to the development of the green energy equipment industry. We commit to society with high-quality, cost-effective products and services!