Shandong Zhongjie Special Equipment Co., Ltd.VIP

中杰特装储罐主营:LNG储罐、LPG储罐、液氧储罐、化工设备等安装服务.
Enter Shop

Chongzuo Low-Temperature Liquid Nitrogen Storage Tank, Factory Direct Supply

平台认证
  • Unit Price

    $10000.00/Tai

  • Brand

    Zhong Jie

  • MOQ

    1Tai

Contact
Leave Msg

Platform Service

Supplier Verified



山东中杰特种装备股份有限公司

VIP   数字营销第2年
资料通过中商114认证
  • Shandong
  • 于秋波 (Mr.)   业务经理
Category
  • No Category

Product Details

Specs

Gallery

  • Brand:

    Zhong Jie

  • Unit Price:

    $10000.00 / Tai

  • MOQ:

    MOQ1Tai

  • Total:

    9999Tai

  • Address:

    Shandong

  • Delivery:

    3days

  • View More

Description

Shandong Zhongjie Special Equipment (formerly Heze Boiler Factory Co., Ltd.) was established in 2001, located at No. 2218 Jinnan Road, Development Zone, Heze City, with a registered capital of 50 million yuan and total assets of 500 million yuan. The company has 7 business centers: boilers, deep-freeze containers, pressure vessels, central air conditioning, engineering installation, international trade, and Internet of Things. It has three factory sites on Jinnan Road, East Changjiang Road, and Bohai Road, covering a total of 200,000 square meters, with the main workshop spanning 83,000 square meters. It currently employs 710 people, including 247 engineers and technicians and 82 intermediate-level technicians. In December 2016, it was recognized as a "High-tech Enterprise" by the Science and Technology Department. In June 2021, it was identified as a "Specialized and New Enterprise in Shandong Province" by the Ministry of Industry and Information Technology. In June 2022, it was recognized as a "Gazelle Enterprise in Shandong Province" and in August 2022, it was identified as a "Specialized and New Small Giant Enterprise" by the Ministry of Industry and Information Technology.
Safe operation of low-temperature liquid storage tanks is crucial and primarily involves the following aspects:
Tank Design and Material Selection: The tank design must comply with relevant safety standards and regulations, capable of withstanding the pressure and temperature of low-temperature liquids. Select appropriate materials such as stainless steel, aluminum alloy, etc., to ensure the tank's corrosion resistance and low-temperature performance.
Insulation and Protection Measures: Low-temperature liquid storage tanks should be equipped with effective insulation to minimize heat transfer and evaporation of the liquid. The selection and installation of the insulation should comply with relevant standards and requirements. Additionally, protective measures such as anti-freezing and explosion-proof measures should be implemented to ensure the safe operation of the tank.
Pressure Control and Safety Valves: Low-temperature liquid storage tanks should be equipped with reliable pressure control systems and safety valves to ensure the pressure inside the tank remains within a safe range. The pressure control system should be capable of promptly detecting and adjusting the pressure inside the tank to prevent risks posed by either excessive or insufficient pressure.
Leak and Fire Protection: Low-temperature liquids are highly flammable, so measures must be taken to prevent leaks and fires. Storage tanks and related pipelines should have good sealing properties and be regularly inspected and maintained to prevent leaks. Additionally, appropriate fire protection facilities and firefighting equipment should be provided to address fire risks.
Safe Operation and Training: Operators must undergo relevant safety training, familiarize themselves with the safety operating procedures and emergency response measures for low-temperature liquid storage tanks. Adhere to proper operational steps to ensure safe operation.
Regular inspections and
崇左低温液氮储罐
Daily inspection content for liquid nitrogen storage tanks mainly includes the following aspects:
Visual Inspection: Check for any obvious damage, deformation, or corrosion on the tank's exterior, including the tank walls, valves, pipes, and joints.
Sealability Inspection: Inspect the storage tank's sealing performance, including checking for any leakage at valve and pipeline connections, and verifying that the exhaust valve and safety valve of the tank are functioning properly.
Pressure Check: Verify that the tank's pressure gauge is functioning properly and that the pressure is within the normal range to ensure the tank operates normally.
Level Inspection: Check the liquid nitrogen tank's level to ensure it's within the normal range, avoiding issues caused by either too high or too low levels.
Insulation Layer Inspection: Check for any damage or detachment in the storage tank's insulation layer to ensure proper insulation and reduce evaporation losses of liquid nitrogen.
Leak Inspection: Check for signs of liquid nitrogen leakage around the storage tank, including frost, ice, or liquid nitrogen stains on the ground.
Safety Equipment Inspection: Verify that the safety equipment of the storage tank, such as leak detectors, alarm systems, and safety valves, is functioning properly to ensure the tank's safety.
Cleaning Inspection: Regularly clean the interior of the tank to remove accumulated impurities and dirt, maintaining cleanliness and hygiene of the tank.
Above are the key items for the daily inspection of liquid nitrogen tanks. The specific inspection items should be adjusted and supplemented according to the tank's model, usage, and relevant regulations. During the inspection process, strict adherence to operational procedures and safety standards is required to ensure the safe operation of the tank.
崇左低温液氮储罐
Maintaining and protecting the accessories of liquid argon storage tanks is a crucial measure to ensure the normal operation and extend their service life. The following are general methods for maintaining and protecting the accessories of liquid argon storage tanks:
Valve Maintenance: Regularly inspect and maintain valves in tank accessories, including intake valves, exhaust valves, safety valves, etc. Ensure valves operate smoothly and reliably with no leakage or jamming. Regularly lubricate valves and remove any debris and dirt.
Pressure Relief Device Maintenance: The pressure relief devices (such as safety valves) within the liquid argon storage tank accessories are critical components for ensuring the internal pressure safety of the tank. Regularly inspect and test the operational status of the pressure relief devices to ensure proper functioning. Clean and repair as needed.
Sensor and gauge maintenance: Sensors and gauges in the liquid argon storage tank accessories are used to monitor and control parameters such as tank temperature and pressure. Regularly calibrate and inspect the accuracy and reliability of the sensors and gauges. Keep the sensors and gauges clean and in proper working order.
Insulation Layer Protection: The insulation layer of liquid argon storage tank accessories is crucial for maintaining the low temperature state of liquid argon. Regularly inspect the integrity and insulating properties of the insulation layer, and repair or replace any damaged insulation materials. Avoid mechanical damage or contamination to the insulation layer.
Cleanliness and Corrosion Protection: Regularly clean the accessories of the tank, removing any impurities and dirt on the surface. Regularly inspect and maintain the corrosion-resistant coating on the accessories to prevent corrosion and oxidation.
Regular Inspections and Maintenance: Conduct comprehensive inspections and maintenance of liquid argon tank accessories on a regular basis, including appearance, fittings, and seals. Promptly identify and address any damage, leaks, or other issues with the accessories.
Record and Document Management: Document each maintenance and service outcome, including the service date, content, identified issues, and corrective measures. Establish comprehensive management records and documents for tracking and managing the operation of the attachments.
Note that maintenance and protection of liquid argon cylinder accessories should be performed by trained personnel, following relevant specifications and standards. Ensure safety during maintenance and operation, and consult with experts for accurate guidance.
崇左低温液氮储罐
Routine inspections of liquid nitrogen tanks should include the following aspects:
Level Check: Regularly inspect the liquid nitrogen tank's level to ensure it remains within the normal range. This can be done using a level gauge or a level ruler, among other equipment.
Pressure Check: Inspect the tank's pressure to ensure it is within the safe range. Pressure gauges or pressure sensors can be used for the inspection.
Insulation Layer Inspection: Verify that the storage tank's insulation layer is intact with no damage or detachment. The integrity of the insulation layer is crucial for reducing heat transfer and the evaporation of liquid nitrogen.
Leak Inspection: Check for signs of liquid nitrogen leakage around the storage tank, such as vapor mist, frost, or freezing. If a leak is detected, take immediate measures to repair it.
Valve and pipeline inspection: Check that the valves and pipelines of the tank are functioning properly without any gas leaks or blockages. Ensure the tightness and unobstructed flow of the valves and pipelines.
Safety Device Inspection: Check the storage tank's safety devices, such as pressure relief valves, temperature sensors, and level alarms, to ensure they are functioning properly.
External Tank Cleaning: Regularly clean the exterior surface of the tank to remove dust, dirt, and debris. Maintain the tank's appearance for easy inspection and maintenance.
Record and Documentation: Timely record the inspection results and maintenance records of the tank, including liquid levels, pressure, insulation condition, leakage status, etc. These records help monitor the tank's operating status and identify issues promptly.
The above lists the daily inspection items for liquid nitrogen tanks. Regularly conducting these checks ensures the safe operation and effective use of the tanks. At the same time, follow relevant safety regulations and operation guidelines to ensure the safety of personnel and equipment.
Shandong Zhongjie Special Equipment, welcome customers to visit our factory for cooperation discussions.

Disclaimer:Info provided by user, user liable for authenticity, accuracy & legality. Zhongshang114 assumes no liability.

Tip:Confirm supplier qualification & quality before purchase to avoid risks.

Unit Price $10000.00 / Tai
Sales None
Delivery Shandong3dayswithin
Stock 9999TaiMOQ1Tai
Brand Zhong Jie
Structural form Vertical
Pressure 0.8 or 1.6 MPa
Type Oxygen, Nitrogen, Argon Storage Vessel
Expiry Long Valid
Update 2025-06-23 17:12
Gallery

Shandong Zhongjie Special Equipment Co., Ltd.Published byChongzuo Low-Temperature Liquid Nitrogen Storage Tank, Factory Direct SupplyGallery Lib

Contact Merchant



Join

Successful Enterprise Join, Enjoy Multiple Privileges

Join Hotline:4006299930

Please scan with mobile phone

Customer Service

Service Hotline:4006299930

Official Account

WeChat Official Account, Get Business Opportunities

Scan to follow WeChat

Top