Shandong Zhongjie Special Equipment Co., Ltd.VIP

中杰特装储罐主营:LNG储罐、LPG储罐、液氧储罐、化工设备等安装服务.
Enter Shop

Morning Sun 5CF Liquid Argon Storage Tank - High Product Safety

平台认证
  • Unit Price

    $10000.00/Tai

  • Brand

    Zhong Jie

  • MOQ

    1Tai

Contact
Leave Msg

Platform Service

Supplier Verified



山东中杰特种装备股份有限公司

VIP   数字营销第2年
资料通过中商114认证
  • Shandong
  • 于秋波 (Mr.)   业务经理
Category
  • No Category

Product Details

Specs

Gallery

  • Brand:

    Zhong Jie

  • Unit Price:

    $10000.00 / Tai

  • MOQ:

    MOQ1Tai

  • Total:

    9999Tai

  • Address:

    Shandong

  • Delivery:

    3days

  • View More

Description

Shandong Zhongjie Special Equipment (formerly Heze Boiler Factory Co., Ltd.) holds an A-grade boiler manufacturing license, an A2-grade pressure vessel manufacturing license, an A2-grade pressure vessel design license, B-grade boiler installation and GB2, GC2 class pressure pipeline installation licenses, as well as equipment and machinery installation contracting qualifications. It is a member of the China Boiler and Water Treatment Association, the China Chemical Equipment Association, and the council unit of the Shandong Equipment Manufacturing Association. The company has also passed the ISO9001 Quality Management System, ISO14001 Environmental Management System, OHSAS18001 Occupational Health and Safety Management System certifications, and the American ASME/U2 certification.
Proper management regulations for the use of low-temperature liquid storage tanks encompass the following aspects:
Tank Selection and Installation: Choose an appropriate low-temperature liquid storage tank and ensure it complies with relevant standards and regulations. The installation should be carried out by personnel and operated according to the manufacturer's instructions and requirements to ensure the stability and safety of the tank.
Safety Operating Procedures: Establish and implement safety operating procedures for liquid storage tanks, including start-up, shutdown, filling, venting, and other operational steps. Operators must receive training to understand the characteristics of liquid storage tanks, safety precautions, and emergency response measures.
Safety Equipment and Protection Measures: Tanks should be equipped with necessary safety devices, such as pressure sensors, safety valves, leak detectors, etc., to monitor and control the pressure and temperature of the tank. At the same time, operators should wear appropriate personal protective equipment, such as insulated gloves, protective clothing, etc., to ensure their own safety.
Regular inspections and maintenance: Regularly inspect and maintain low-temperature liquid storage tanks, including checking the tank's appearance, seals, and corrosion protection measures. In case of any issues, address them promptly by repairing or replacing the tank to ensure its proper operation and safety.
Waste Management: Low-temperature liquid storage tanks that are no longer in use should be disposed of in accordance with relevant environmental regulations. The remaining liquids in the废弃tanks should be handled properly to prevent environmental pollution.
Tank Records and Tracking: Establish tank usage records, including filling dates, quantities, and usage status. Additionally, it is recommended to implement a tank tracking system for monitoring and managing tank usage and maintenance.
Here are some common management regulations for low-temperature liquid storage tanks, with specific regulations potentially varying by industry and region. When using low-temperature liquid storage tanks, relevant laws and standards must be adhered to, and appropriate management measures should be established based on actual circumstances.
朝阳5方液氩储罐
The use and operation of the liquid oxygen storage tank system should be mindful of the following points:
Safe Operation: When operating the liquid oxygen storage tank system, it is mandatory to adhere to relevant safety operating procedures and standards to ensure the safety of operators.
Tank Selection: Choose liquid oxygen tanks that meet specifications and standards, ensuring their quality and safety performance.
Tank Installation: Tanks should be installed on a solid foundation to ensure stability. Additionally, good ventilation should be maintained around the tank, and it should be kept away from flammable materials and heat sources.
Seal Integrity Inspection: Regularly check the sealing performance of the storage tank system to ensure there are no leaks at valve and pipeline connections.
Pressure Control: Storage systems should be equipped with pressure gauges and safety valves, with regular inspections and maintenance to ensure pressure remains within safe limits.
Fire Prevention Measures: Liquid oxygen contains a high concentration of oxygen, which is highly flammable. Set up fire barriers around the storage tank system, prohibit smoking and open flames, and ensure safety.
Static Protection: During the operation of the liquid oxygen system, static electricity may cause sparks, increasing the risk of fire. Measures such as using static-conductive materials and anti-static equipment are taken to reduce the accumulation and release of static electricity.
Regular Inspections and Maintenance: Conduct regular inspections of the storage tank system and related equipment, including valves, pipes, pressure gauges, etc. Ensure that the equipment is in perfect condition without any damage, and promptly repair or replace any damaged parts.
Waste Gas Treatment: During the operation of the liquid oxygen system, waste gas is produced, and appropriate waste gas treatment measures must be taken to minimize environmental impact.
Above are the precautions to be noted when using the liquid oxygen storage tank system, ensuring operation safety and the normal operation of the system. During operation, strict adherence to the relevant operational procedures and safety operation requirements should be followed to avoid accidents.
朝阳5方液氩储罐
During the operation of low-temperature storage tanks, it is indeed necessary to avoid the occurrence of wrinkling. Wrinkling refers to the phenomenon where the tank walls develop creases or deformations, which can lead to a decrease in the structural strength of the tank and may even cause leaks or ruptures.
Here are some precautions to avoid crushing in low-temperature storage tanks:
Tank Design: Select an appropriate tank design that can withstand the pressure and weight of low-temperature liquids. The tank's wall thickness, support structure, etc., should comply with relevant standards and regulations.
Material Selection: Choose materials suitable for low-temperature environments, with adequate strength and low-temperature resistance. Common materials include low-temperature steel, stainless steel, etc.
Insulation Layer for Storage Tanks: The design and construction of the insulation layer must meet the requirements to ensure effective reduction of heat conduction and temperature variations. The materials and thickness of the insulation layer should be selected based on specific conditions.
Tank Operation: During the loading and unloading process of liquids in the tank, it is essential to avoid rapid or excessive fluid flow to minimize impact and stress concentration on the tank walls.
Tank Maintenance: Regularly inspect and maintain the structure and insulation of the tanks to ensure they remain undamaged. Any abnormalities or damage should be repaired or replaced promptly.
Temperature Control: During the operation of low-temperature liquid storage tanks, it is crucial to strictly control the temperature difference between the inside and outside of the tank to avoid excessive temperature fluctuations and thermal stress.
In summary, preventing tank deformation in low-temperature storage is crucial through proper design, material selection, insulation installation and maintenance, as well as strictly controlling temperature variations. Regular inspections and maintenance are also essential for ensuring safe operation of the storage tank.
朝阳5方液氩储罐
To prevent the explosion of liquid oxygen tanks, the following measures can be taken:
Regular inspections and maintenance: Conduct regular checks and maintenance on liquid oxygen tanks, including inspecting the tank's exterior, welds, valves, and connections, to ensure they are intact and damage-free. Regularly clean the tanks to remove impurities and dirt adhering to the surface.
Pressure Control: Storage tanks should be equipped with pressure control devices to ensure internal pressure is within a safe range. Regularly inspect and adjust the pressure control devices to ensure their proper operation.
Temperature Control: Liquid oxygen tanks should be maintained within an appropriate temperature range to prevent excessive heat from causing pressure increase. Ensure the tank's insulation is intact to minimize heat conduction and loss.
Fire Prevention Measures: Liquid oxygen has a high oxygen content and flammability, so strict fire prevention measures are required. A fire-resistant buffer zone should be established around the storage tank, and smoking and open flames are prohibited. Ensure that the storage tank maintains a certain fire-resistant distance from other facilities.
Pressure relief devices and safety valves: Liquid oxygen storage tanks should be equipped with pressure relief devices and safety valves to prevent overpressure and sudden pressure increases. Regularly inspect and test the operational status of the pressure relief devices and safety valves to ensure they are functioning properly.
Tank Operation Standards: Adhere strictly to the operational specifications and safety requirements for liquid oxygen tanks. Operators must be trained and familiar with the tank's characteristics and operating techniques. Avoid operational errors and violations.
Emergency Preparedness: Establish and conduct emergency response plans and drills to address potential accidents. Train operators in emergency response capabilities to ensure timely and effective responses.
Our company highly values technological innovation and R&D, boasting 1 municipal-level enterprise technology center in Heze City. We have established testing facilities for non-destructive testing, physical and chemical testing, welding testing, hydrostatic testing, etc. We are equipped with over 600 instruments and equipment, including CNC machine tools, X-ray flaw detectors, digital ultrasonic flaw detectors, mechanical property testing machines, chemical analyzers, spectrometers, tensile testing machines, plasma welding machines, and more. The key products and technologies we have developed, such as welding for temperature and pressure vessels, emission reduction of biomass boilers, and waste heat utilization, have successively been shortlisted for multiple Shandong Provincial Department of Industry and Information Technology innovation projects, Shandong Provincial key projects, and Heze City innovation and excellence projects. We have cumulatively obtained 27 authorized utility models, 16 authorized inventions, participated in drafting 2 standards, 2 industry standards, and registered 15 trademarks. Our technical team, in collaboration with Professor Li Yajiang of Shandong University, has jointly developed deep cryogenic vessel processing technology using the international plasma arc + wire-filled tungsten inert gas arc welding (PAW-GTAW) technology. This technology has been appraised as reaching an international level in the field of deep cryogenic vessel manufacturing at the provincial level. Choose ZJ Special Equipment, let's join hands to create brilliance!

Disclaimer:Info provided by user, user liable for authenticity, accuracy & legality. Zhongshang114 assumes no liability.

Tip:Confirm supplier qualification & quality before purchase to avoid risks.

Unit Price $10000.00 / Tai
Sales None
Delivery Shandong3dayswithin
Stock 9999TaiMOQ1Tai
Brand Zhong Jie
Structural form Vertical
Pressure 0.8 or 1.6 MPa
Type Oxygen, Nitrogen, Argon Storage Tanks
Expiry Long Valid
Update 2025-06-23 08:50
Gallery

Shandong Zhongjie Special Equipment Co., Ltd.Published byMorning Sun 5CF Liquid Argon Storage Tank - High Product SafetyGallery Lib

Contact Merchant



Join

Successful Enterprise Join, Enjoy Multiple Privileges

Join Hotline:4006299930

Please scan with mobile phone

Customer Service

Service Hotline:4006299930

Official Account

WeChat Official Account, Get Business Opportunities

Scan to follow WeChat

Top