Shandong Zhongjie Special Equipment (formerly Heze Boiler Factory Co., Ltd.) holds an A-grade boiler manufacturing license, an A2-grade pressure vessel manufacturing license, an A2-grade pressure vessel design license, a B-grade boiler installation license, and GB2/Class and GC2/Class pressure pipeline installation licenses, as well as a qualification for electromechanical equipment installation contracts. It is a member of the China Boiler and Water Treatment Association, the China Chemical Equipment Association, and the director unit of the Shandong Equipment Manufacturing Association. The company has also passed certifications for the ISO9001 Quality Management System, ISO14001 Environmental Management System, OHSAS18001 Occupational Health and Safety Management System, and the American ASME/U2 certification.
To prevent liquid oxygen storage tank explosions, the following measures can be taken:
Regular Inspections and Maintenance: Conduct regular inspections and maintenance on liquid oxygen tanks, including checking the tank's exterior, welds, valves, and fittings, to ensure they are intact and undamaged. Regularly clean the tank to remove any impurities and dirt adhering to its surface.
Pressure Control: Storage tanks should be equipped with pressure control devices to ensure the internal pressure of the tank remains within a safe range. Regularly inspect and adjust the pressure control devices to ensure proper operation.
Temperature Control: Liquid oxygen tanks should be maintained within an appropriate temperature range to prevent excessive heat from causing pressure increase. Ensure the insulation layer of the tank is intact to minimize heat conduction and loss.
Fire Prevention Measures: Liquid oxygen has a high oxygen content and flammability, so strict fire prevention measures must be taken. A fire-resistant buffer zone should be established around the storage tank, and smoking and open flames are prohibited. Ensure that the storage tank maintains a safe distance from other facilities for fire prevention.
Pressure relief devices and safety valves: Liquid oxygen storage tanks should be equipped with pressure relief devices and safety valves to prevent overpressure and sudden pressure increases. Regularly inspect and test the operational status of the pressure relief devices and safety valves to ensure their proper functioning.
Tank Operation Guidelines: Strictly adhere to the operational specifications and safety requirements for liquid oxygen tanks. Operators must be trained and familiar with the tank's characteristics and operating techniques. Avoid operational errors and violations.
Emergency Preparedness: Establish emergency response plans and conduct drills to address potential accidents. Train operators in emergency response capabilities to ensure timely and effective handling.
那曲液氧储罐
Daily inspection of liquid nitrogen storage tanks primarily includes the following aspects:
Visual Inspection: Check for any visible damage, deformation, corrosion, etc., on the tank's exterior, including the tank walls, valves, pipes, and joints.
Sealability Inspection: Verify the tank's sealing performance, including checking for leaks at valve and pipe connections, and ensuring the tank's exhaust and safety valves are functioning properly.
Pressure Check: Verify that the tank's pressure gauge is functioning properly and that the pressure is within the normal range to ensure the tank operates normally.
Level Check: Monitor the liquid nitrogen tank's level to ensure it stays within the normal range, avoiding issues caused by levels that are too high or too low.
Insulation Layer Inspection: Check for any damage or detachment in the storage tank's insulation layer to ensure effective insulation and minimize evaporation losses of liquid nitrogen.
Leakage Inspection: Check for signs of liquid nitrogen leakage around the tank, including frost, ice, or liquid nitrogen residue on the ground.
Safety Equipment Inspection: Verify that the storage tank's safety equipment, such as leak detectors, alarm systems, and safety valves, are functioning properly to ensure the tank's safety.
Cleaning Inspection: Regularly clean the interior of the tank to remove accumulated impurities and dirt, maintaining the tank's cleanliness and hygiene.
Above are the key items for daily inspections of liquid nitrogen tanks. The specific inspection items should be adjusted and supplemented according to the tank's model, usage, and relevant regulations. During the inspection process, strict adherence to operational procedures and safety requirements is essential to ensure the safe operation of the tank.
那曲液氧储罐
Liquid nitrogen tanks are widely used in various industries, primarily in the following aspects:
Industry: Liquid nitrogen tanks are used in the field for storing and supplying liquid nitrogen, employed for cryogenic preservation of biological samples, cells, tissues, and vaccines. These tanks are widely used in biopharmaceutical research institutions, biobanks, and other similar establishments.
Experimental Research: Liquid nitrogen tanks are used in scientific research and laboratories to provide low-temperature environments, for cryopreservation and cryogenic experiments. Liquid nitrogen tanks play a crucial role in experimental research across various fields such as physics, chemistry, biology, and materials science.
Metalworking Industry: Liquid nitrogen tanks are used in the metalworking and welding industries for providing low-temperature cooling, for processes such as metal cutting, welding, and heat treatment. The tanks can achieve the required hardness and toughness of the metal during processing by providing low temperatures.
Food Industry: Liquid nitrogen tanks are used in the food industry for freezing and refrigeration of foods, such as frozen meats, frozen fruits, and frozen seafood, etc. The low temperature of liquid nitrogen can quickly freeze foods, preserving their freshness and quality.
Semiconductor Industry: Liquid nitrogen tanks are used in semiconductor manufacturing and the electronics industry to provide low-temperature environments, for the freezing and preparation of semiconductor materials. The low temperature of liquid nitrogen can enhance the purity and performance of semiconductor materials.
The configuration of liquid nitrogen tanks typically includes the following aspects:
Tank Structure: Liquid nitrogen tanks usually feature a double or multi-layered design, filled with insulating material in the middle to minimize heat transfer and evaporation of liquid nitrogen. The tank material is typically stainless steel or aluminum alloy, offering excellent corrosion and low-temperature resistance.
Insulation Layer: The insulation layer of liquid nitrogen tanks typically employs multi-layered insulation materials, such as polyethylene foam, glass fiber, and vacuum layers, to minimize heat transfer and evaporation of liquid nitrogen.
Temperature Control System: Liquid nitrogen tanks are typically equipped with a temperature control system to regulate the tank's temperature, maintaining the liquid state.
那曲液氧储罐
Routine inspections and maintenance of liquid oxygen storage tanks are crucial for ensuring their safe operation. The following are general steps for the daily inspection and maintenance of liquid oxygen storage tanks:
Appearance Inspection: Regularly inspect the tank's exterior, including the shell, welds, valves, and fittings. Pay attention to any abnormal conditions such as cracks, corrosion, or deformation.
Leak Detection: Utilize appropriate leak detection equipment to inspect tanks and connection points for any leaks. Leak detection can be conducted using methods such as gas detectors or liquid oxygen detection agents.
Pressure Testing: Conduct regular pressure tests to check the tank's sealing and pressure resistance. Perform pressure tests in accordance with relevant standards and specifications, and record the test results.
Valve and Fitting Inspection: Check that the tank's valves and fittings are functioning properly, for any signs of looseness or damage. Ensure the valves operate smoothly and reliably.
Insulation Layer Inspection: Verify that the tank's insulation is intact without any damage or detachment. Repair or replace any damaged insulation materials to ensure effective insulation.
Cleaning and Waste Disposal: Regularly clean the interior of the tank to remove accumulated impurities and dirt. Regularly dispose of waste to prevent contaminants and sediments in liquid oxygen from damaging the tank.
Safety Equipment Inspection: Examine the safety equipment around the storage tanks, such as fire isolation zones and alarm systems, to ensure they are functioning properly.
Record and Document Management: Document each inspection and maintenance result, including the inspection date, contents, issues found, and corrective measures. Establish comprehensive management records and documents for tracking and managing the tank's operational status.
Note that inspections and maintenance of liquid oxygen tanks should be conducted by trained personnel and in accordance with relevant regulations and standards. Ensure safety during maintenance and operations, and consult experts for accurate guidance.
ZJ Special Equipment upholds the grand vision of "realizing the dreams of our employees, creating value for our customers, and striving for the prosperity and strength of our motherland," wholeheartedly devoting ourselves to the development of green energy equipment, and offering society high-value products and services!

Disclaimer:Info provided by user, user liable for authenticity, accuracy & legality. Zhongshang114 assumes no liability.

Tip:Confirm supplier qualification & quality before purchase to avoid risks.

Unit Price $10000.00 / Tai
Sales None
Delivery Shandong3dayswithin
Stock 9999TaiMOQ1Tai
Brand Zhong Jie
Structural form Vertical
Pressure 0.8 or 1.6 MPa
Type Oxygen, nitrogen, argon storage tanks
Expiry Long Valid
Update 2025-06-19 08:46
Gallery

Shandong Zhongjie Special Equipment Co., Ltd.Published byNagqu Liquid Oxygen Cylinder, made of 304 stainless steelGallery Lib

Contact Merchant



Join

Successful Enterprise Join, Enjoy Multiple Privileges

Join Hotline:4006299930

Please scan with mobile phone

Customer Service

Service Hotline:4006299930

Official Account

WeChat Official Account, Get Business Opportunities

Scan to follow WeChat

Top