Shenzhen ZhongNuo Inspection Technology Co., Ltd.VIP

防爆认证,防爆合格证,防爆电气检测,防爆资质证书办理,ATEX和IECEX认证
Enter Shop

Petroleum Chemical Factory Explosion Proof Equipment Regular Inspection Application Requirements, Online Inquiry

平台认证
  • Unit Price

    $500.00/None

  • Brand

    ZhongNuo Inspection

  • MOQ

    1None

Contact
Leave Msg

Platform Service

Supplier Verified



深圳中诺检测技术有限公司

VIP   数字营销第2年
资料通过中商114认证

Product Details

Specs

Gallery

  • Brand:

    ZhongNuo Inspection

  • Unit Price:

    $500.00 / None

  • MOQ:

    MOQ1None

  • Total:

    99999None

  • Address:

    GuangdongShenzhen

  • Delivery:

    3days

  • View More

Description

Shenzhen ZhongNuo Inspection & Technology Co., Ltd. offers on-site explosion-proof electrical inspection, explosion-proof project acceptance, and related consulting services. We also provide explosion-proof rectification and construction services for items that fail inspection.
ZheNuo Inspection's On-site Explosion Proof Inspection Service Scope:
Explosive gas environments and hazardous areas with flammable or combustible dust in industries such as oil, chemicals, coal, shipping, ports, marine engineering, gas engineering, pharmaceuticals, machinery, textiles, electricity, light industry, grain processing and storage, and wood processing must ensure the anti-explosion safety of dangerous explosive sites to safeguard the economic development of our country and the national economy.
化工厂防爆设备定期检查申请条件 在线咨询
Certification Report for Explosion-Proof Electrical Construction Completion Application Agency:
It's widely known that after electrical work in explosive hazardous areas is completed, a third-party organization must conduct a post-completion inspection. Only upon passing the inspection can the facility be put into use. Additionally, apart from regular checks by the company itself, a facility with explosion-proof inspection qualifications must conduct periodic inspections every three years.
Here, we first share what the main items are for the acceptance inspection after completion?
1. Check if the explosion-proof electrical equipment has a label, an Ex mark, and clear identification of the type, class, and group of the explosion-proof equipment. Does the label indicate the explosion-proof certificate number issued by the inspection unit?
2. Inspect the type, grade, group, environmental conditions, and special markings of explosion-proof electrical equipment to ensure compliance with regulations.
3. Inspect the shell of explosion-proof electrical equipment for cracks or damage; ensure the paint is intact, that the junction box cover is securely fastened, and that the fixing bolts and anti-loosening devices are in place.
4. Check for oil leakage and seepage in oil-filled electrical equipment, and ensure the oil level meets the required specifications.
5. Ventilation and exhaust systems of explosion-proof electrical equipment with positive pressure should be unobstructed, connections should be properly made, and the installation positions of inlets and outlets should meet the requirements.
6. Are the extra entry ports of the explosion-proof electrical equipment properly sealed in accordance with regulations?
7. The installation of sealed or insulated devices in electrical circuits should comply with regulations.
8. The wiring engineering of intrinsic safety explosion-proof electrical equipment shall comply with design requirements for the route and elevation of the lines; the lines should be marked with a sky blue sign.
9. The grounding or neutral grounding of explosion-proof electrical equipment, as well as anti-static grounding, should meet the design requirements and be firm and reliable.
10. At the time of completion and acceptance, the relevant documents, materials, manufacturer's product user manuals, test records, qualification certificates, and installation drawings, along with other technical files, should be submitted.
11. At the time of inspection, the following measurement records should also be submitted:
Record of measurement for the single-sided air gap of the stator and rotor in explosion-proof motors with increased safety.
(2) Adjustment records for pressure-relief devices protecting explosion-proof electrical equipment, such as wind and air pressure relays; high-temperature records of the equipment's housing during trial operation; and test records of the grounding resistance for static electricity protection.
12. Explosion-proof electrical equipment operation records
The shell temperature of explosion-proof electrical equipment, including intrinsically safe and non-sparking explosion-proof electrical equipment, should not exceed the specified value.
(2) After internal wiring in the junction box is securely fastened, the electrical clearances and creepage distances between live parts and between live parts and the metal enclosure shall comply with regulations.
(3) Exhaust outlets of explosion-proof electrical equipment with positive pressure should not blow out sparks. The micro-pressure relay should operate reliably when reducing wind pressure and air pressure.
(4) The protection and interlock devices of explosion-proof electrical equipment should operate correctly and reliably.
化工厂防爆设备定期检查申请条件 在线咨询
How to conduct explosion-proof safety inspections on electrical equipment in use?
In accordance with the AQ3009-2007 "Electrical Explosion Protection Safety Regulations for Hazardous Areas," explosion-proof electrical equipment in use must undergo a regular explosion-proof inspection at least every 3 years to ensure their explosion-proof performance. The inspection items include the selection, installation, wiring, static electricity, grounding, and more of the explosion-proof equipment. Inspection methods include visual inspections, general inspections, and detailed inspections. This requires on-site inspections, where the client must provide information on the area of the explosion-proof zone, the number of electrical equipment, and the MSDS on-site. After the on-site inspection is completed, a report with explosion-proof improvement suggestions or an explosion-proof inspection report will be issued based on the actual situation.
ZhongNuo Inspection has provided on-site explosion-proof electrical inspection services for various facilities such as gas stations, oil depots, food factories, feed mills, chemical plants, and more. We also offer explosion-proof correction and construction services for non-compliant items identified during on-site inspections, with a wealth of successful cases and industry experience. If you happen to need an on-site explosion-proof electrical inspection report, feel free to private message us for detailed communication.
化工厂防爆设备定期检查申请条件 在线咨询
After the explosion-proof project is completed, it requires a third-party institution with explosion-proof inspection qualifications (Shenzhen ZhongNuo Inspection Technology Co., Ltd.) to conduct the project acceptance. Only after passing the acceptance can the project be put into use.
Blast-proof project acceptance criteria
1. The explosion-proof equipment label must include the explosion-proof certificate number issued by the inspection unit.
2. Types, classes, and groups of explosion-proof electrical equipment should comply with the design.
3. The housing of explosion-proof electrical equipment should be free from cracks or damage; the paint should be intact. The cover of the junction box should be securely fastened, and the fixing bolts and anti-loosening devices should be in place.
4. The ventilation and exhaust systems of positive pressure electrical equipment should be unobstructed, correctly connected, and the import and export installation positions should meet the requirements.
5. Excess electrical equipment entry ports should be sealed as per regulations.
6. The installation of sealed devices in electrical circuits should comply with regulations.
7. Wiring engineering for intrinsically safe electrical equipment should conform to the design, with the routing and elevation of the lines; the lines should be marked with a sky blue sign.
8. Grounding or neutral bonding of electrical installations and anti-static wiring must comply with design requirements and be secure and reliable.
On-Site Explosion-Proof Electrical Equipment Regular Inspection Consulting Service - Shenzhen Zhongnuo Inspection Technology Co., Ltd.

Disclaimer:Info provided by user, user liable for authenticity, accuracy & legality. Zhongshang114 assumes no liability.

Tip:Confirm supplier qualification & quality before purchase to avoid risks.

Unit Price $500.00 / None
Sales None
Delivery GuangdongShenzhen3dayswithin
Stock 99999NoneMOQ1None
Brand ZhongNuo Inspection
Service Fields Chemical zones, oil depots, gas stations, petrochemical areas, workshops, etc.
As per AQ 3009-2007
Regulatory requirements Every three years, one inspection
Expiry Long Valid
Update 2025-06-05 17:49
Gallery

Shenzhen ZhongNuo Inspection Technology Co., Ltd.Published byPetroleum Chemical Factory Explosion Proof Equipment Regular Inspection Application Requirements, Online InquiryGallery Lib

Contact Merchant



Join

Successful Enterprise Join, Enjoy Multiple Privileges

Join Hotline:4006299930

Please scan with mobile phone

Customer Service

Service Hotline:4006299930

Official Account

WeChat Official Account, Get Business Opportunities

Scan to follow WeChat

Top