Shandong Zhongjie Special Equipment Co., Ltd.VIP

中杰特装储罐主营:LNG储罐、LPG储罐、液氧储罐、化工设备等安装服务.
Enter Shop

Manufacturer of LPG Storage Tanks for Sale

平台认证
  • Unit Price

    $1.00/Tai

  • Brand

    Zhong Jie

  • MOQ

    1Tai

Contact
Leave Msg

Platform Service

Supplier Verified



山东中杰特种装备股份有限公司

VIP   数字营销第2年
资料通过中商114认证
  • Shandong
  • 于秋波 (Mr.)   业务经理
Category
  • No Category

Product Details

Specs

Gallery

  • Brand:

    Zhong Jie

  • Unit Price:

    $1.00 / Tai

  • MOQ:

    MOQ1Tai

  • Total:

    9999Tai

  • Address:

    Shandong

  • Delivery:

    3days

  • View More

Description

Our company specializes in tank-type pressure vessels, which are one of our key products. These include LPG storage tanks, liquid ammonia tanks, liquid chlorine tanks, propane tanks, pentane storage tanks, and low-temperature storage tanks for liquid oxygen and nitrogen. Particularly, our LPG storage tanks have reached mass production levels with a continuous production line, and various models are available in stock.

III Class Storage Tank Performance Parameters Statistics Sheet

Tank Type Product Model Effective Volume m³ Working Pressure MPa External Dimensions mm

LPG Storage Tank

[On the ground]

WG 1.77-1400-551.77DN1400×2750

WG 1.77-1400-10101.77DN1400×5980

WG 1.77-1600-10101.77DN1600×4400

WG 1.77-2000-20201.77DN2000×5650

WG 1.77-2200-25251.77DN2200×5800

WG 1.77-2200-30301.77DN2200×7100

WG 1.77-2600-40401.77DN2600×6600

WG 1.77-2600-50(B)501.77DN2600×8500

WG 1.77-2600-60601.77DN2600×10360

WG 1.77-3000-1001001.77DN3000×13200

WG 1.77-3600-1201201.77DN3600×10500

WG 1.77-3600-1501501.77DN3600×13500

WG 1.77-3800-2002001.77DN3800×16300

LPG Storage Tank

[Underground]

WDG 1.77-1400-551.77DN1400×2750

WDG 1.77-1600-10101.77DN1600×4400

WDG 1.77-2200-25251.77DN2200×5770

WDG 1.77-2200-30301.77DN2200×7100

WDG 1.77-2600-50501.77DN2600×8500

WDG 1.77-2800-60601.77DN2800×8740

WDG 1.77-3000-1001001.77DN3000×13200

Supply of listed company He Guo brand LPG storage tanks, ranging from 5 to 200 cubic meters of LPG storage tanks




专业定制液化气储罐哪家质量好-知名液化气储罐价格-销售液化气储罐批发价-正规液化气储罐制造厂


Use Instructions

1. Cylinders must be stored in well-ventilated areas, with a minimum distance of 1.5 meters from any fire or heat source. Cylinders should not be heated with fire, boiled in water, or exposed to direct sunlight. Regularly inspect the cylinder valves and pipeline joints for leaks, ensuring they remain airtight. Typically, soap water is used to check for leaks; open flames for testing are strictly prohibited.

2. When lighting, ignite the igniter first, followed by opening the gas; do not reverse the order. There should be a supervisor present during use and never leave the area to prevent boiling water from spilling and extinguishing the flame, which could lead to a gas leak causing an explosion. After use, the valve on the gas cylinder must be tightly closed to prevent gas leakage.

3. The liquefied gas inside the cylinder should not be completely depleted, leaving a certain residual pressure. The residual pressure should generally be greater than 49.03 kPa (i.e., 0.5 kg/cm², gauge pressure) to prevent air from entering the cylinder. After the liquefied petroleum gas is used up, the remaining residue in the cylinder is also a flammable substance and should not be poured out arbitrarily to prevent fires caused by the flow and evaporation of the residue.

4、Liquefied Petroleum GasCylinders are pressurized containers that require proper maintenance and regular inspections. Prevent falls or impacts during handling and use. Do not use metal tools to strike the valve opening and protect from direct sunlight and prolonged exposure to rain. Cylinders should be inspected every 2 years.

5、PetroleumLiquefied gas has a relatively narrow explosive range, but due to its low limit, it can easily ignite and explode upon leakage. Additionally, LPG is heavier than air, so when it leaks into the atmosphere, it tends to flow downwards and accumulate in low-lying areas, posing a hidden danger of gas explosion. Therefore, areas prone to gas leakage require more than just window ventilation; attention must be given to proper ventilation at lower levels.

6. When a liquefied gas leak is detected indoors, windows and doors should be opened immediately for ventilation, allowing the gas to disperse away from any open flame. No fire is permitted in the vicinity. The area should only be used after the fault is resolved and the distinctive odor has dissipated. Any leaked liquid on the ground should be covered with sand and soil before being removed to a safe location. In case of a gas cylinder fire, shut off the valve immediately, move it to an open area outdoors, and extinguish the fire using dry powder extinguishers, carbon dioxide extinguishers, or by covering it with a wet sack.

7. Educate children not to tamper with gas cylinders at will, and users must be aware of the safety knowledge regarding gas cylinder use.





LPG Storage Tanks - Heze Boiler Factory Co., Ltd. - Professional Manufacturer of LPG Storage Tank Models - Leading LPG Storage Tank Company - Sell Professional LPG Storage Tanks

Disclaimer:Info provided by user, user liable for authenticity, accuracy & legality. Zhongshang114 assumes no liability.

Tip:Confirm supplier qualification & quality before purchase to avoid risks.

Unit Price $1.00 / Tai
Sales None
Delivery Shandong3dayswithin
Stock 9999TaiMOQ1Tai
Brand Zhong Jie
Inventory Quantity 9999
Working Voltage 380V
Effective Water Volume Detailed Inquiry
Expiry Long Valid
Update 2025-05-29 08:38
Gallery

Shandong Zhongjie Special Equipment Co., Ltd.Published byManufacturer of LPG Storage Tanks for SaleGallery Lib

Contact Merchant



Join

Successful Enterprise Join, Enjoy Multiple Privileges

Join Hotline:4006299930

Please scan with mobile phone

Customer Service

Service Hotline:4006299930

Official Account

WeChat Official Account, Get Business Opportunities

Scan to follow WeChat

Top