Product Description


Brand Hegu Group Model CFW-100/0.8

Material: Stainless Steel, Diameter: 3400mm

Application Range: -162℃; Volume: 100,000L

Heat exchange area - See drawing in square meters (㎡) Environmental temperature - See drawing in degrees Celsius (℃)

Wall Thickness: 10/12mm, Dimensions: 3424*16442mm

Origin: Shandong Heze

    


60-cubic-meter LNG tank price  30 cubic meter to 60 cubic meter LNG storage tank suppliers


3. LNG Tank Fault Inspection and Handling 3.1 Daily Inspections


3.1.1 Level gauge and pressure gauge operation check.


3.1.2 Are the stop valves, regulating valves, and safety valves in normal working condition?


3.1.3 Tank, pipelines, and valves for any leaks.


3.2 Regular inspections


3.2.1 The pressure gauge should be calibrated annually and accompanied by a certificate of compliance with a lead seal.


3.2.2   The safety valve should be calibrated annually and sealed with lead.


3.2.3   Liquid at low temperatures should be analyzed every three to six months as needed for operation.


3.3 Fault Handling


Occurred fault


Original Cause


Processing Measures


1. Abnormal inner tube pressure


(raise or lower)


A Pressure Gauge Distortion


B tank vacuum reduced


Operation Error with C Valve


A pressure gauge


B heavy vacuuming


C follows the manual's instructions for operation


2 Level Gauge Distortion


Improper operation of the level gauge valve


The B level gauge is damaged.


Reoperate as per requirement


B Replace with New Level Gauge


3 External tank frosting


Vacuum Failure


B-laminate leakage


C Pearl-like sand sinking


A re-evacuate the vacuum


B pressure test and leak check, then evacuate air


C-balance interlayer reinstallation of pearl sand followed by vacuum extraction


Note:


1. If the user needs to evacuate or re-install pearlescent sand in the sandwich, they must first empty the inner cylinder's liquid and wait until the inner cylinder returns to room temperature before proceeding.


2. If users encounter issues that are difficult to handle, they may contact our after-sales service department promptly. Our company provides three guarantees for the quality of its products, and also offers repair services for products beyond the warranty period and those not manufactured by our company.


4. Cautionary Notes


4.1 The vacuum valve is sealed before the product is shipped out. After the storage tank is delivered to the customer's site, the customer must ensure the protection of all pipeline valves during installation, especially the vacuum valve, and strictly prohibit any collision or opening of the vacuum valve.


4.2 Do not empty the liquid in the tank unless it will not be used for a long period, to prevent the inner cylinder from overheating and requiring recooling when refilling, which would unnecessarily increase losses.


4.3 Low-temperature liquid storage tanks can be used to store liquid nitrogen, liquid oxygen, and liquid argon, among other three liquids. However, when switching to another liquid, the original liquid must be completely drained and purged to a qualified standard before refilling with the new liquid.


Note:


1. The measuring full valve opens when the liquid is almost full, closes when liquid starts to flow, and stops the inflow. When filling for the first time, it should be filled from the top first, then from the bottom.


2. Open when draining residual liquid.


3. Release the venting valve when the container pressure is too high.


4. The container automatically opens when over-pressurized. Normally, only one is in use; if the working one malfunctions, the other is immediately activated to ensure the safety of the storage tank. The damaged safety valve is then repaired and inspected, and upon passing, is promptly reinstalled.


5. The inner cylinder automatically starts upon opening the pressure-increasing valve when pressure boost is required.


6. The level gauge is often turned off during normal operation.


7. Blast upon overpressure; immediate replacement required after blast.


 









 

Natural Gas Storage Tank Price - 100 Cubic Horizontal LNG Storage Tank Direct from Manufacturer - Competitive Price, High Vacuum Degree


Product Description


Brand Hekou Group Model CFW-30/0.8

Material: Stainless Steel, Diameter: 2916mm

Application Range    -162℃    Volume    30000L

Heat Exchange Area - See drawing sq. m, Environmental Temperature - See drawing °C

Wall Thickness: 8/10mm, External Dimensions: 2916*8289mm

Origin: Shandong, Heze

    



Horizontal LNG Storage Tank 30 Cubic LNG Storage Tank 60 Cubic LNG Storage Tank 100 Cubic Natural Gas Storage Tank



Low-temperature LNG storage tanks are double-layered structures, with the inner tank storing low-temperature natural gas liquids, bearing the pressure and low temperature of the medium. The material of the inner tank is SS30408. The outer shell serves as a protective layer for the inner tank, maintaining a certain gap to form an insulating space, and bears the gravitational loads of the inner tank and the medium, as well as the vacuum negative pressure of the insulating layer. The outer shell does not come into contact with the low temperature and is made of container steel. The insulating layer is mostly filled with mica sand, with a high vacuum level. The evaporation rate of low-temperature LNG storage tanks is generally less than 0.2%.



Low-Temperature LNG Storage Tank Structural Design


1.1 Liquid Filling System


The filling is divided into top filling and bottom filling, equipped with a quick connector CN-1 and a four-way connector, which are connected to the top filling valve V3 and the bottom filling valve V2 respectively. Tubes and transition connectors are connected to the inner cylinder.


Tubes are selected in φ28×2 and φ45×3.5 sizes.


1.2 Drainage System


The valve V6 can directly drain fluid, connected from the bottom of the cylinder; the pipes are selected in φ45×3.5 size. V6 is chosen with 32gDA25C, with specifications of DN40 PN4.0.


1.3 Vacuum Measurement System


VR vacuum silicon tubes, used for measuring the vacuum degree of the tank's sandwich layer, connected to the exhaust pipe of the sandwich. When the vacuum degree of the vacuum layer exceeds 3Pa, the sandwich should be re-evacuated to ensure the vacuum degree of the sandwich and enhance the insulation effect.


1.4 Vacuum Insulation Panel System


VV vacuum vent, selecting CF-40 with DN of 40, for vacuum extraction; when the vacuum level reaches the required standard, close the VV to maintain the interlayer vacuum.


1.5 Level Measurement System


Two pipes are extracted from the upper and lower parts of the cylinder, with the top being the vapor phase and the bottom the liquid phase, connected together by the level gauge valve. L1 level gauge valve PS×Z-1, the gas connection is to the pressure gauge valve and pressure gauge, the liquid level measurement range is 0~6m water column.


1.6 Full Mouth Measurement


Install the pipeline based on the set liquid level. When the liquid level reaches the set value, it flows downward through the pipe to the level valve MV. When filling, this valve opens until liquid starts to flow out, indicating the tank is full. Close the valve. Use a 32gDA10C valve. Specifications: DN20 PN4.0.


1.7 Self-pressurizing System


The pressure booster valve V1 is connected to the PBC-1 supercharger, which uses the CFB03-00 model. It vaporizes a portion of the liquid flowing from the tank and introduces it into the inner tank, thereby increasing the pressure inside the tank, causing the liquid to be expelled under pressure.


1.8 Gas Venting System


When the pressure at the top of the container increases, gas is expelled through the pipeline, then through the vent valve E1, and into a one-way valve CV. Since gas can only flow out, a one-way valve is used to prevent backflow. A flame arrester is then connected because gas release and contact with air can cause sparks. The flame arrester is designed to prevent sparks from entering the inner tank with the gas, which could ignite and cause an explosion.



 

Horizontal LNG Tank 30 Cubic LNG Tank 60 Cubic LNG Tank 100 Cubic Natural Gas Tank





专业生产液化天然气储罐多少钱-供应液化天然气储罐多少钱-菏泽锅炉厂有限公司液化天然气储罐供应商-现货液化天然气储罐制造商

Disclaimer:Info provided by user, user liable for authenticity, accuracy & legality. Zhongshang114 assumes no liability.

Tip:Confirm supplier qualification & quality before purchase to avoid risks.

Unit Price $1.00 / Tai
Sales None
Delivery Shandong3dayswithin
Stock 9999TaiMOQ1Tai
Brand Zhong Jie
Inventory Quantity 9999
Operating Voltage 380V
Effective Water Volume For detailed inquiries
Expiry Long Valid
Update 2025-05-29 08:43
Gallery

Shandong Zhongjie Special Equipment Co., Ltd.Published byWholesale Prices for Liquefied Natural Gas TanksGallery Lib

Contact Merchant



Join

Successful Enterprise Join, Enjoy Multiple Privileges

Join Hotline:4006299930

Please scan with mobile phone

Customer Service

Service Hotline:4006299930

Official Account

WeChat Official Account, Get Business Opportunities

Scan to follow WeChat

Top