Shandong Zhongjie Special Equipment Co., Ltd.VIP

中杰特装储罐主营:LNG储罐、LPG储罐、液氧储罐、化工设备等安装服务.
Enter Shop

40 cubic meter liquid oxygen tank, over 20 years of experience for added peace of mind

平台认证
  • Unit Price

    $10000.00/Tai

  • Brand

    Zhong Jie

  • MOQ

    1Tai

Contact
Leave Msg

Platform Service

Supplier Verified



山东中杰特种装备股份有限公司

VIP   数字营销第2年
资料通过中商114认证
  • Shandong
  • 于秋波 (Mr.)   业务经理
Category
  • No Category

Product Details

Specs

Gallery

  • Brand:

    Zhong Jie

  • Unit Price:

    $10000.00 / Tai

  • MOQ:

    MOQ1Tai

  • Total:

    9999Tai

  • Address:

    Shandong

  • Delivery:

    3days

  • View More

Description

Shandong Zhongjie Special Equipment's main products include: fuel (gas) boilers, organic heat carrier boilers, biomass boilers, waste heat boilers, and other boiler products; vacuum insulation cryogenic pressure vessels such as LNG tanks, oxygen-nitrogen-argon tanks, and CO2 tanks; pressure vessel products such as denitrification engineering equipment, heat storage and energy storage equipment, and complete chemical equipment; central air conditioning and HVAC equipment such as ground (water) source heat pumps, air-source units, water-cooled screw units, and air-cooled modular units. Planned products include large-scale energy centers, LNG transport vehicles, LNG tank containers, and other green energy equipment.
The stable pressure design of a 15 cubic meter liquid argon storage tank requires consideration of the following aspects:
Tank Pressure: Determine the design pressure of the tank to meet the storage and supply requirements for liquid argon. Establish an appropriate design pressure range based on the properties and usage conditions of liquid argon.
Stabilization System: Choose an appropriate stabilization system to maintain stable pressure within the storage tank. The stabilization system typically includes components such as pressure regulators, pressure sensors, and control valves, which are used to monitor and adjust the pressure inside the tank.
Pressure Sensor: Install a pressure sensor to monitor the pressure changes inside the tank in real-time. The sensor transmits pressure signals to the pressure regulation system, enabling timely adjustment of the control valve to maintain stable pressure within the tank.
Control Valve: Select an appropriate control valve for regulating the gas flow and pressure within the storage tank. The control valve should have excellent regulating performance and stability to ensure the pressure within the tank remains within the set range.
Safety Valve: Install a safety valve to automatically release gas when the pressure inside the storage tank exceeds the set value, preventing overpressure. The safety valve should be selected and installed based on the design pressure and capacity of the storage tank.
Voltage Stabilization System Control: Equipped with a suitable control system for monitoring and regulating the operation of the voltage stabilization system. The control system enables automatic adjustments and alarm functions to ensure stable and safe pressure within the storage tank.
Note that the design of the voltage stabilization should be tailored to the specific engineering requirements and usage conditions of the liquid argon storage tank, adhering to relevant local regulations, standards, and specifications. When designing and installing the voltage stabilization system, it's advisable to consult with an engineer or relevant institutions for guidance to ensure the reliability and safety of the system.
40方液氧储罐
Material control for low-temperature liquid storage tanks is a crucial aspect for ensuring safety and reliability. The following are some common material control measures:
Material Selection: Choose materials suitable for low-temperature environments, such as low-temperature alloy steel, stainless steel, etc. These materials possess excellent low-temperature resistance and crack resistance, maintaining strength and toughness under low-temperature conditions.
Material Quality Control: Ensure the selected materials meet relevant standards and specifications. Conduct chemical composition analysis, mechanical property tests, and impact tests on materials to confirm their performance meets design requirements.
Welding Material Selection: Choose welding materials suitable for low-temperature environments, such as low-temperature welding rods or welding wires. The welding materials should match the storage tank material, offering excellent welding properties and crack resistance.
Welding Process Control: Monitor welding process parameters such as current, voltage, and welding speed to ensure the quality and reliability of weld joints. Methods with low heat input, such as pulse welding and laser welding, can minimize the temperature gradient and residual stress in the heat-affected zone.
Corrosion Protection Measures: Apply corrosion-resistant coatings and paints to the internal and external metal surfaces of storage tanks to extend their service life. This protects the metal structure from corrosion damage.
Material Performance Monitoring: Regularly monitor the tank materials for performance, such as mechanical property tests,
40方液氧储罐
Protection techniques for liquid nitrogen storage tanks include the following:
Wear Protective Gear: When handling liquid nitrogen tanks, it is mandatory to wear appropriate protective gear, including protective gloves, suits, and non-slip shoes. This gear helps protect the skin from the low temperature of liquid nitrogen and other hazards.
Avoid direct contact: Liquid nitrogen is extremely cold and can cause frostbite. Therefore, it is essential to avoid direct contact with liquid nitrogen, especially with the skin. Use tools or equipment for handling, and prevent hands from coming into direct contact with liquid nitrogen.
Note ventilation: In the operational area of the liquid nitrogen tank, ensure adequate ventilation to expel gases produced by the evaporation of liquid nitrogen. Maintain air circulation to avoid high oxygen concentrations, reducing the risk of fire and explosion.
Prevent Leaks: Regularly inspect liquid nitrogen tanks for leaks, equip with leak detectors and alarm systems. In case of a leak, take immediate action to control and repair it. Avoid harm to personnel and the environment from liquid nitrogen leaks.
Fire Prevention Measures: Nitrogen liquid has a low boiling and freezing point, which is prone to causing fires. Measures such as setting up fire barriers around nitrogen liquid storage tanks and using fire-resistant coatings are taken to prevent fires from occurring and spreading.
Electrostatic Protection: The accumulation of static electricity in liquid nitrogen tanks may cause sparks, increasing the risk of fire. Measures such as using electrostatic conductive materials and anti-static equipment should be taken to reduce the buildup and release of static electricity.
Regular Inspections and Maintenance: Conduct regular checks on the condition of liquid nitrogen tanks and related equipment, including valves, pipes, pressure gauges, etc. Ensure the equipment is intact and promptly repair or replace any damaged parts.
Waste Gas Treatment: Liquid nitrogen tanks produce waste gas during operation, which must be appropriately treated.
40方液氧储罐
Liquid Oxygen Storage Tanks are specialized equipment that requires special attention to safety and an understanding of their characteristics. Below are the precautions and features for using liquid oxygen storage tanks: **Precautions:** - **Operation:** The operation of liquid oxygen storage tanks should be carried out by trained and experienced personnel. Operators should be familiar with the tank's structure, performance, and operational procedures, and should operate strictly according to the operation manual and safety regulations. - **Fire Prevention Measures:** Liquid oxygen is highly oxidizing and can easily cause fires and explosions. Open flames and hot objects should be prohibited around the storage tank to prevent sparks and contact. Fire prevention facilities and fire extinguishing equipment should be established and regularly inspected and maintained. - **Leakage Control:** In the event of a leakage in a liquid oxygen storage tank, immediate measures should be taken to control the leakage. Leaks can cause the evaporation of liquid oxygen and an increase in oxygen concentration, which can raise the risk of fire and explosion. A leakage alarm system should be established, and leakage control devices and personal protective equipment should be provided. - **Insulation Protection:** Liquid oxygen storage tanks should have good insulation protection to reduce evaporation of liquid oxygen and maintain low temperatures. The insulation layer should be regularly inspected and maintained to ensure its integrity and insulating performance. - **Safety Distance:** A certain safety distance should be maintained around the liquid oxygen storage tank to prevent the spread of fires, explosions, and leaks. The specific requirements for safety distance should be assessed and determined according to local regulations and standards. **Features:** - **High Oxidizing Property:** Liquid oxygen has a high oxidizing property, which can support combustion and cause more intense burning. Therefore, special attention must be paid to fire and explosion prevention measures when using liquid oxygen storage tanks. - **High-Pressure Storage:** Liquid oxygen storage tanks typically store high-pressure oxygen, with pressures usually around 2-5 bar. Therefore, when operating and maintaining liquid oxygen storage tanks, attention should be given to pressure control and the safety of pressure relief devices. - **Low-Temperature Storage:** The liquid oxygen in the storage tank is at a low temperature, usually around -183°C. Therefore, when contacting the liquid oxygen storage tank, appropriate protective measures should be taken.
Zhejiang Zhejie Special Equipment Co., Ltd. adheres to the great vision of "realizing employees' dreams, creating customer value, and striving for the prosperity and strength of our motherland," focusing on the development of green energy equipment industry, and devoting high-quality, cost-effective products and services to society!

Disclaimer:Info provided by user, user liable for authenticity, accuracy & legality. Zhongshang114 assumes no liability.

Tip:Confirm supplier qualification & quality before purchase to avoid risks.

Unit Price $10000.00 / Tai
Sales None
Delivery Shandong3dayswithin
Stock 9999TaiMOQ1Tai
Brand Zhong Jie
Structural form Vertical
Pressure 0.8 or 1.6 MPa
Type Oxygen, Nitrogen, Argon Storage Vessel
Expiry Long Valid
Update 2025-05-27 15:10
Gallery

Shandong Zhongjie Special Equipment Co., Ltd.Published by40 cubic meter liquid oxygen tank, over 20 years of experience for added peace of mindGallery Lib

Contact Merchant



Join

Successful Enterprise Join, Enjoy Multiple Privileges

Join Hotline:4006299930

Please scan with mobile phone

Customer Service

Service Hotline:4006299930

Official Account

WeChat Official Account, Get Business Opportunities

Scan to follow WeChat

Top