Shenzhen ZhongNuo Testing Technology Co., Ltd. specializes in the calibration, certification, and metrological services for gas alarms, flammable gas detectors, toxic and harmful gas detectors, and other equipment in various locations. We provide services nationwide, addressing various electrical safety and explosion-proof fire prevention issues for clients, and promoting safe production.
Gas Detector Alarm Calibration Specification Requirements
Regulation 5.5 of the "Regulation for Inspection and Verification of Combustible Gas Detectors" (JJG693-2011) stipulates: The inspection cycle for combustible gas detection and alarm instruments: The general inspection cycle for the instrument should not exceed one year. If there is any doubt about the instrument's measurement data, or if the instrument has been replaced with major components or repaired, it should be promptly sent for inspection.
Section 3.5 of the "Regulations for the Use of Flammable Gas Detection and Alarm Systems" (SY6503-2000) stipulates: The flammable gas detection and alarm systems in use shall be calibrated regularly in accordance with the regulations.
Occupational Health Service Facilities Toxic Gas Equipment Installation Specification (GBZ/T223-2009) Article 7.2.1 stipulates: Calibration of detection and alarm devices should be carried out regularly according to the manufacturer's specified time and procedures.
Section 3.4 of the "Regulations for the Use of Combustible Gas Detectors" (SY6503-2000) stipulates: Combustible gas detectors for installation and use shall have measurement instruments manufactured by an institution recognized for their **explosion-proof performance**.
Appearance and structure
The instrument should not have any surface damage that affects its normal operation. The surface of newly manufactured instruments should be smooth and even, with a uniform paint and coating, free of peeling and rusting.
The instrument's connections are reliable, and all dials or buttons should operate and control normally.
Logos and Branding
Instrument name, model, manufacturer, date of manufacture, serial number, explosion-proof marking and number, as well as the domestic instrument's manufacturing measuring instrument license marking and number, should be clear.
Instrument Calibration Control
The instrument control includes calibration, follow-up calibration, and in-service inspection.
The calibration cycle for flammable gas detectors is typically once a year.
In accordance with the standard JJG 693-2011 "Flammable Gas Detectors," the calibration cycle for flammable gas detectors generally does not exceed one year. This means that, under normal circumstances, a comprehensive calibration and testing of the flammable gas detectors should be conducted annually to ensure their performance meets the relevant requirements.
Shenzhen ZhongNuo Testing Technology Co., Ltd. is a third-party institution specializing in electrical safety, electrical explosion-proofing, gas alarm systems, and toxic/hazardous gas detection equipment for regular inspections, metrological measurements, and calibration services. We are qualified to address fire and explosion prevention issues for our clients.