Boiler Cleaning Machine GQ-300, Boiler Pipe Cleaner, Drain Cleaning Equipment
Suitable for cleaning dirt, grease, silt, debris, etc. from the interiors of various pipelines. Widely applicable to pipeline facilities in residential areas, offices, hotels, schools, and property communities.
1. Machine plug Insert single three-way outlet.
2. On/off control knob for the unit.
"O" to stop; "L" to reverse; "R" to forward
3. When installing Φ16 flexible shaft, pull it out about 150mm, insert it along with the accessories shaft into the shaft hole at the rear of the machine. After pushing it flat, pull out the pin, rotate it to the left to engage the mounting bracket with the locating block at the end of the machine, and then release the pin bolt to allow it to snap into the Φ16 hole, completing the installation of the accessories.
4. Install the flexible shaft and blade head; align the T-slot and insert it, then push the pin in and release it to lock the joint.
5. During use, the machine should be kept in alignment with the pipe end. Maintain a distance similar to the height of the machine. Press down on the operating handle with your hand, while simultaneously gripping the rotating flexible shaft, push or pull it along the naturally formed curve to insert into the pipe opening.
Operation Precautions
Before operation, check for any abnormalities in the machine; otherwise, stop using it.
2. To ensure operations , Utilize single-pole three-way plugs and outlets with good grounding.
3. When the insulation resistance of the machine is less than 2MΩ, it should be suspended for use. It should be dried and ventilated, and can be used again only when the insulation resistance exceeds 2MΩ.
4. On narrow sites or Environmental operations, should be reliable Protection with supervision.
5. When operating in damp or waterlogged areas, reliable Safety measures: Use a residual current device. Place the machine on a raised, dry area free of water. Wear insulating gloves and shoes.
6. After completion of operations, unplug the power cord first, followed by cleaning up the site.
7. The machine should be properly maintained and lubricated before and after use.
8. Non-electrical personnel or non-specialists are prohibited from dismantling or repairing this machine without authorization.
Do not rinse the machine with water directly to prevent accidental damage to the insulation layer.