O-type gate with hydraulic push-pull rod, electric actuator, parallel push rod
Electro-hydraulic Push RodElectric manual two-way hydraulic push rods, parallel electric hydraulic push rods, and straight electric hydraulic push rods are mining construction products specially supplied by mining equipment factories for construction projects in various mines. They are available in a wide range and supplied year-round to both large and small coal mines.
The electro-hydraulic actuator is primarily composed of six basic elements: the type of actuator, the protection grade of the motor, the rated output force, stroke, rated speed, and usage angle. It can also be customized according to the user's requirements. Requirements: Three adjustable functions included, namely: speed adjustment, pull-push force adjustment, and stroke adjustment (stroke switch positioning). In addition to the aforementioned three adjustable functions, please specify at the time of ordering: Please fill in the six basic elements carefully, referring to the model compilation method, except for any noted otherwise. Please provide the Chinese content you would like translated into American English."Taking the DYTZB1000-500/110-X type electro-hydraulic push rod as an example, we will explain how to select the type and model." Compilation method.
1. Selection Guide: A site requires a vertical integrated electro-hydraulic push rod with explosion-proof motor. It needs a maximum thrust of 10kN, stroke of 500mm, and maximum speed of 110mm/s, operating in a downward push angle. The standard model for the electro-hydraulic push rod would be: DYTZB1000-500/110-X. (B indicates the explosion-proof feature.) For details on the electro-hydraulic push rod, electric hydraulic push rod DYTZ, XDGZ push rod, and electric push rod, including price, manufacturer, model, and images, please contact us for the latest information.
About the maintenance of electro-hydraulic push rods, adhere to the following:
1. Regularly filter or replace hydraulic oil; do so annually or at an interval based on actual usage.
2 The lifespan of the high-pressure oil pipe, use rubber to secure the pipe properly.
3. Basic Troubleshooting
After a period of use, if the unit fails to operate, remove the liquid control plug, clean the valve core of the liquid control valve, and replace the hydraulic oil.
The machine cannot move upon initial installation; check if the motor is not running or if the oil level is insufficient.