Ethyl Propionate Chromatograph for Liquor Spirits Baijiu Ethyl Butyrate Chromatograph
As of the current situation in the domestic market,Company'sIn reality, offering economic and affordable solutions.Our solutions for the beverage industryAnd categoryOur company's quality control and production certifications provide robust support, with test results meeting national standards.
One:ChromatographyMeasureSamplesMedium-chain esters
Method Principle: This method employsSpecializedPlease provide the Chinese content that needs to be translated into American English.ChromatographyColumns, equipped with a hydrogen flame ionization detector, quantify the alcohol ester content in spirit wine using n-butyl acetate as the internal standard.
Determined Components: Acetaldehyde, Ethyl acetate, n-Propyl alcohol, sec-Butanol, Ethyl methyl ketone, Isobutanol, n-Butanol, Butyl acetate, Isoamyl alcohol, Amyl acetate, Lactyl acetate, Hexyl acetateHydrocarbons。
Quantified by internal standard method. The internal standard is ethyl butyrate.
AppropriateDetermination in food, compliantGB-5009.266-2016
Main Configuration:
OneFilling Column with Constant Temperature Function
1. GC9800Gas Chromatography MainframeSingle Filling Column Single FID Detector
2. Chromatography Workstation
TwoQuick analysis of capillary column type
Gas Chromatography Main Unit (Capillary分流/不分流 injection, FID detector, 8-step programmable temperature rise with automatic back door opening)
2. Chromatography Workstation
3. 30m × 0.32mm Capillary Chromatography Column for Wine Analysis
Method of Determination
Item 2: Large-bore capillary column for determining alcohols and esters in wine
Method Principle: This method utilizes a large bore capillary column specifically designed for spirits, with detection by a hydrogen flame ionization detector.
Determine Composition:C2 to C6 and over 20 other components
Features: Compared to packed columns, it has higher separation ability, faster separation speed, and better inertness; compared to small-bore capillary columns, it has a larger column capacity, is not demanding of sample injection techniques, and can avoid the discriminatory effect caused by分流. Analysis time is short, approximately15min。
Detector Technical Specifications:
Detector | Sensitivity/Sensitivity | Noise | Drift | Linear | Features |
FID | Mf≤1×10 -11 g/s(Benzene) | ≤ 0.02mV | ≤ 0.15mV/h | ≥107 | Circular collection electrode, sapphire ceramic nozzle |
Note: Dimensions (外形尺寸): 660*460*465mm Overall Weight:60 kg Input Power:AC 220V±10% 50HZ 2KW | |||||


Baijiu Gas Chromatography Analyzer