VOCs Chromatograph/Tovc ChromatographVOCs Analyzer/Tovc Chromatograph   VOCs Analyzer/Tovc Chromatograph

TVOC is a type of indoor air pollutant that is particularly harmful among the three main pollutants. It can evaporate into the air at room temperature, posing toxicity, irritability, carcinogenicity, and distinctive odors that can harm the skin and mucous membranes, causing acute damage to the human body. The primary sources of TVOC are outdoors, mainly from fuel combustion and transportation. Indoors, the main sources are the smoke from coal and other combustion products, smoking, heating, cooking, building and decorative materials, furniture, household appliances, emissions from furniture, cleaning agents, and the human body itself.

  

  Tovc ChromatographIndoor Air Quality Monitoring System for Benzene and TVOC Detection (Five-Item Package)

Product Item

Specification Description

Quantity

Unit

GC-9800

Tovc Chromatograph

Chromatograph Main Unit + Dual Gas Path Control System + Dual Sample Injection System + Amplification Circuit Control + Dual CPU Control System + Main Unit Fault Diagnosis with Audio-Visual Chinese Display + Dual Output System

1

Set

Detector

Dual FID Detector (Atmospheric Monitoring Type)

2

Just

Chromatography Column

Chromatography Column

1

Root

Workstation System

SP-2000 Dual-Channel Multi-Function Workstation + Random Accessories

+Computer + Printer

1

Set

Hot analysis

Automatic Thermal Desorption Instrument + Adsorption/Desorption Device

1

Set

Atmospheric Sampler

Dual-Channel Atmospheric Sampler + Activated Carbon Adsorption Tube

1

Set

Launch Toolkit

Randomly included (over 30 types)

1

Set

Standard Sample

Sample

1

Set

Gas Source

Generator

Air Generator

High-purity nitrogen gas

1

1

1

Set

Set

Canister

Key Performance Features:

1. The instrument features a full microcomputer automatic control system, with an adjustable LCD display that offers rich and intuitive content; the Chinese keyboard operation allows for easy parameter setting and operation.

2. Features a new dual-CPU design and original, high-integrated Japanese electronic circuit technology, offering excellent reliability and anti-interference capabilities. The temperature control precision reaches 0.1°C, with the display accuracy up to 0.01°C, and it can simultaneously show the power consumption percentage of each heating section.

3. The design features a triple gas path and a large-volume column chamber, allowing for the simultaneous installation of three chromatography columns, as well as both FID and TCD detectors. It also facilitates the easy expansion of ECD, FPD, and NPD detectors, and the addition of gas injection systems and reformers, among other external control equipment.

4. The machine can be easily expanded from a single FID amplifier to a dual FID amplifier, truly realizing multi-functional use with one unit.

5. Equipped with two packed column vaporization chambers and an independent capillary tube system. The vaporization chamber design draws inspiration from the miniaturized design of similar foreign products, offering fast heating, no sampling dead spots, and excellent capillary分流/不分流 injectors and tail gas systems. It allows for easy installation of small-bore capillary columns, large-bore capillary columns, and various packed columns.

6. Features a five-stage linear temperature ramping function, suitable for analysis of multi-component samples.

7. The column chamber features a variable frequency intelligent automatic cooling system, which cools down rapidly (from 280℃ to 50℃ in just 5 minutes), achieving near-room temperature operation in a true sense.

8. Equipped with a six-way independent temperature control system, suitable for applications requiring multiple temperature controls, such as installation of conversion furnaces. The column chamber, gasification chamber, hydrogen flame detection room, thermal conductivity detection room, auxiliary 1, and auxiliary 2 all feature modular design for easy installation and replacement.

9. Features power failure protection and auto-memorization of set parameters. Equipped with anti-power surge interference and stopwatch timing functions.

10. Features over-temperature protection, automatically shutting off power and alarming when the temperature exceeds the set limit. If any temperature exceeds the set temperature, the heating will automatically stop; with an indication of the fault cause and alarm prompt.

11. Features "0℃" protection. If any temperature display remains at "0℃" at all times, the heating will automatically shut off to prevent damage to the heating element from continuous heating. It also provides a fault cause prompt and an alarm alert.

12. Our product features an air-cut protection and alert function, which maximizes protection for TCD tungsten filaments and chromatography columns from damage.

13. Wide-range fault self-diagnosis function with 36 types of self-diagnostic information, displaying the cause and solution of the fault at any time.

14. Stable airway system:

(1) The gas flow utilizes a dual stability design with pressure stabilization followed by flow stabilization.

The airway control valves in (2) feature high repeatability and stability.

15. Multiple sample submission methods available:

(1) Filling column head sample insertion

(2) Filled column gas chromatography injection

(3) Capillary Split/Splitless Injection: Backpressure valve control technology, linear splitting.

(4) Six-way valve gas sampling

(5) Automated headspace sampling

Temperature Control Specifications:

1) Column box: Room temperature +5℃-400℃; Accuracy: 0.1℃; Display accuracy up to 0.01℃

2) Sample Loader: Operating temperature +5℃ to 400℃; Accuracy: 0.1℃; Display accuracy up to 0.01℃

3) Detector: Operating temperature +5℃ to 400℃; Accuracy: 0.1℃; Display accuracy up to 0.01℃

4) Column Oven Volume: 248*248*260MM

5) Program升温 Step: Five-Step Linear升温

6) Heating Rate: 0.1℃ ~ 40℃ (0.1℃ increment)

7) Temperature-holding time for various levels: 0~9999.9 min (0.1 min increment)


Detector Technical Specifications:

Detector Sensitivity/Sensitivity Noise Drift Linearity Characteristics FIDM f ≤ 1×10^-11 g/s (Benzene) ≤ 0.02 mV ≤ 0.15 mV/h ≥ 10^7 Circular Collector, Corundum Ceramic Nozzle Note: External Dimensions: 660*460*465mm, Total Machine Weight: 60 kg, Input Power: AC 220V±10%, 50Hz, 2KW Each instrument can be equipped with up to 3 detectors, with interfaces reserved for adding 2 more detectors.


Attachment 1: (This unit is configured with a FID detector, featuring available interface for additional options, allowing the addition of any two out of detectors 2, 3, 4, or 5)

1. The TCD detector (Thermal Conductivity Detector) is one of the most widely used detectors, suitable for inorganic gases and organic compounds, particularly well-suited for constant analysis or analysis of components at concentrations above ten parts per million.

2. FID Detector (Hydrogen Flame Ionization Detector) with high sensitivity, suitable for trace analysis of organic substances.

3. The ECD detector (Electron Capture Detector) is a low-energy radioactive detector widely used in atmospheric and water quality pollution detection. It is suitable for analyzing organic complexes of halides, polyhalides, polycyclic aromatic hydrocarbons, and metal ions.

4. FPD Detector (Flame Photometric Detector), suitable for analyzing phosphorus-containing compounds and monitoring trace levels of phosphorus-containing organic pollutants in environmental analysis.

5. The NPD detector (Nitrogen-Phosphorus Detector) is a quality tester suitable for the high-sensitivity and high-selectivity detection of nitrogen and phosphorus compounds; it can detect nitrogen-containing compounds like azobenzene at a level of 5×10(-13) g/s and phosphorus compounds such as Marathon at 2.5×10(-13) g/s. It has a high response to nitrogen and phosphorus compounds and a low response to other compounds, typically 10,000 to 100,000 times lower.


Disclaimer:Info provided by user, user liable for authenticity, accuracy & legality. Zhongshang114 assumes no liability.

Tip:Confirm supplier qualification & quality before purchase to avoid risks.

Unit Price $0.01 / Tai
Sales None
Delivery ShandongJinan
Stock 100TaiMOQ1Tai
Brand Precision Testing
Product Features National Standards
Is Importing No
Origin Shandong
Expiry Long Valid
Update 2024-04-16 09:56
Gallery

Jinan Precision Measurement Electronics Technology Co., Ltd.Published byShandong Gas Chromatography ManufacturerGallery Lib

Contact Merchant



Join

Successful Enterprise Join, Enjoy Multiple Privileges

Join Hotline:4006299930

Please scan with mobile phone

Customer Service

Service Hotline:4006299930

Official Account

WeChat Official Account, Get Business Opportunities

Scan to follow WeChat

Top