The Castle Series Tower C1-3K is a widely available and popular online C1-3kVA UPS in the Chinese market. With 30 years of experience and advanced digital control technology, it addresses 9 power issues (power outage, voltage sag, surge, under-voltage, over-voltage, electronic interference, frequency fluctuation, transient, harmonic distortion, others), further enhancing the product's adaptability and reliability, ensuring protection for both user equipment and the UPS itself. C1-3kVA Main Application Scenarios: * IT and Network Equipment: Small servers and workstations, switches, and monitoring devices * Embedded and Automation Control Systems: ATM machines, ticket vending machines, power and railway signaling systems, SCADA monitoring systems * Office and Business Equipment: Office computers, printers, scanners, POS machines, and more.
___________________________________________________
Application Scenarios
Small to medium-sized servers and workstations, switches, and monitoring equipment
ATM machines, ticket dispensers, power and railway signaling systems, SCADA systems
Office computers, printers, scanners, POS machines, and other equipment
Widespread inventory; safe and reliable
Popular and widely available online UPS systems, with over 30 years of experience, adaptable to China's power environment.
Wide input voltage and frequency range, suitable for stringent power environments
Mature digital control technology, robust power semiconductor devices, triple hardware and software protection for enhanced safety and reliability.
Green power design, energy-saving and environmentally friendly
Output power can reach up to 0.9, delivering more energy
High-efficiency electrical design, achieving up to 90% efficiency in online mode, saving operational costs and reducing emissions further.
Green and eco-friendly, in compliance with all the requirements of the EU Environmental Directive.
Ultra-wide input voltage and frequency range
Exquisite manufacturing process
Advanced SMD surface mount technology and CPU integrated control technology enhance the reliability of the TwinGuard (TG) series UPS. It reliably handles various power issues (power outages, short circuits, overloads, high/low voltage, surges) to protect the load.
Intelligent humanized design, flexible and scalable
Batteries are easily configurable to meet varying discharge time requirements.
Smart real-time battery monitoring, battery status at your fingertips
A variety of optional accessories, adaptable to diverse requirements.
| Model | 1K | 1KS | 2K | 2KS | 3K | 3KS | ||
| Capacity | VA/W | 1000VA/800W | 2000VA/1600W | 3000VA/2400W | ||||
| Input Parameters | Input Voltage Range | 115~300VAC | ||||||
| Frequency Range | 40Hz-70Hz | |||||||
| Input connection | National Standard | |||||||
| Input Harmonic Distortion | < 10% Non-linear Full Load | |||||||
| Input Power Factor | ≥0.98 | |||||||
| Output Parameters | Output Voltage | 220VAC | ||||||
| Output Precision | ±2% | |||||||
| Output Connection | GB 10A *2 | GB 10A *2 | GB 10A *4 | GB 10A *4 | GB 10A*3 Output Terminal Block | GB 10A*3 Output Terminal Block | ||
| Locking Range | 46-54Hz/54-66Hz | |||||||
| Output Frequency (Battery Mode) | 50/60Hz±0.05Hz | |||||||
| Peak Current Ratio | 3:1 | |||||||
| Output Harmonic Distortion | <4% (linear load) | |||||||
| <7% (non-linear load) | ||||||||
| Output Waveform | Pure sine wave output | |||||||
| Overload Capacity | Mains Power Mode | 105% ~ 150% : 47s ~ 25s 150% ~ 200% : 25s ~ 300ms >200% : 200ms | ||||||
| Battery Mode | ||||||||
| Efficiency | Mains Power Mode | >89% | >90% | >90% | ||||
| Battery and charging parameters | Battery Voltage | 24VDC | 36VDC | 48VDC | 72VDC | 72VDC | 96VDC | |
| Battery Type | 9AH | Dependent on user requirements and configuration | 9AH | Subject to customer requirements and configuration | 9AH | Based on user requirements and configuration | ||
| Backup Time | >4.5min | >4.5min | >4.5min | |||||
| Rebound Time | 7 hours to 90% recharge | 7 hours to 90% recharge | 7 hours to recharge to 90% | |||||
| Charging Current | 1.0A | 6.0A | 1.0A | 6.0A | 1.0A | 6.0A | ||
| Conversion Time | Battery Mode <--> Mains Power Mode | 0ms | 0ms | 0ms | 0ms | 0ms | 0ms | |
| Display | LED | Load / Battery Capacity / Input / Output / Operating Mode | ||||||
| Physical Parameters | (WxHxD)mm | 144x229x345 | 144x229x345 | 190x328x393 | 190x328x393 | 190x328x393 | 190x328x393 | |
| Operating Environment Temperature | 0-40℃ | |||||||
| Environmental Parameters | Operating Environment Humidity | 20-90% (no dew) | ||||||
| Noise | <45dB at 1 meter | <50dB at 1 meter | ||||||
| Standards and Certification | IEC61000, IEC62040, GB7260,GB4943 | |||||||
| TLC / Energy-saving Certification / Broadcasting Certification | ||||||||
| Communication and Monitoring | RS232 | Standard Configuration | ||||||
| Expandable Slots (Optional) | You may choose NMC Cards, CMC Cards, AS400 Cards, or USB Cards. | |||||||
| EPO (Optional) | Emergency shutdown | |||||||
| Software | Winpower | |||||||