The SANTAK ARRAY series lead-acid batteries utilize thin-plate clean lead technology, achieving a fusion of rapid charging and discharging with long float life, thus pioneering a new paradigm in battery applications for the UPS industry. ARRAY batteries are adaptable to higher environmental temperatures, boast a longer service life, and offer easier installation and maintenance, effectively reducing the cost of battery applications for customers and enhancing the safety of system usage.
___________________________________________________
Application Scenarios
UPS Uninterruptible Power Supply
Communication System
Security Backup Power Supply
Instrumentation and equipment fields
Long-lasting design
Utilizing clean lead technology, the plate purity is significantly higher, suitable for higher temperatures, with an ultimate application temperature up to 80 degrees; it is also more corrosion-resistant, with an expected float life of 20 years at room temperature.
Low self-discharge rate
The grid is designed with a high-density crystal structure, featuring a low self-discharge rate and a storage life of up to two years, significantly exceeding industry standards.
Rapid charge and discharge
The ARRAY series batteries are designed for high power, with a focus on compatibility with UPS systems and optimized system costs. Employing thin plate technology, they enhance the total reactive contact area of the plates, enabling the ARRAY batteries to excel in fast charging and high-power discharge performance, perfectly integrating with the characteristics of UPS applications.
High safety level
The housing meets the 94-V0 flame retardancy level and is made of ABS+PC alloy material, offering high heat resistance, high strength, and long lifespan.
High consistency
Automated production processes ensure high efficiency, excellent consistency in plate and battery performance, making it particularly suitable for multi-string applications in UPS systems.
Easy installation and maintenance
Front-end terminal design ensures safer, more convenient maintenance and installation.
| Model | Rated Voltage (V) | Rated Power @15Min (W) | C10 (Ah) | Dimensions (mm) | Weight / kg | Terminal form | Internal Resistance / mΩ | |||
| Length / L | Width / W | High / H | Total Height / TH | Terminal Specifications | ||||||
| A12-150W | 12 | 150 | 38 | 298.7 | 97 | 184 | 184 | 12.5 | M6 | 6 |
| A12-232W | 12 | 232.6 | 62 | 298.7 | 97 | 267 | 267 | 19.1 | M6 | 5.6 |
| A12-347W | 12 | 347.9 | 90 | 405.4 | 108 | 287 | 287 | 28.7 | M6 | 4.6 |
| A12-425W | 12 | 425.3 | 110 | 559 | 125 | 227 | 227 | 36.5 | M6 | 4 |
| A12-567W | 12 | 567 | 150 | 559 | 125 | 277 | 277 | 48 | M6 | 3.7 |
| A12-601W | 12 | 601.9 | 170 | 559 | 125 | 320 | 320 | 54.2 | M6 | 3.6 |
| A12-694W | 12 | 694 | 190 | 559 | 125 | 320 | 320 | 57.6 | M6 | 3.0 |
| A12-730W | 12 | 730 | 210 | 559 | 125 | 328 | 328 | 60.5 | M6 | 2.9 |
Weight tolerance is ±5%.