Inquiry and Order Phone: 15311707982 (same as WeChat)
The Castle Series Tower C1-3K is a widely available and popular online C1-3kVA UPS in the Chinese market. With 30 years of experience and advanced digital control technology, it addresses 9 power issues (power outage, voltage sag, surge, under-voltage, over-voltage, electronic interference, frequency fluctuation, transient, harmonic distortion, others) to further enhance the product's adaptability and reliability, ensuring protection for both user equipment and the UPS itself. C1-3kVA Main Application Scenarios: * IT and Network Equipment: Small servers and workstations, switches, and monitoring equipment * Embedded and Automation Control Systems: ATM machines, ticket vending machines, power and railway signaling systems, SCADA monitoring systems * Office and Business Equipment: Office computers, printers, scanners, POS machines, and more.
___________________________________________________
Application Scenarios
Small to medium-sized servers and workstations, switches, and monitoring equipment
ATM machines, ticket dispensers, power and railway signaling systems, SCADA systems
Office computers, printers, scanners, POS machines, and other equipment
Wide stock, safe and reliable
Popular online UPS with ample stock, over 30 years of experience, adaptable to China's power environment.
Extensive input voltage and frequency range, suitable for stringent power environments
Advanced digital control technology, robust power semiconductor devices, triple hardware and software protection, enhanced safety and reliability
Green power design, energy-saving and environmentally friendly
Output power can reach up to 0.9, providing more energy
High-efficiency electrical design, achieving up to 90% efficiency in online mode, saving operational costs and reducing emissions further.
Green and eco-friendly, meeting all the requirements of the EU environmental directives.
Ultra-wide input voltage and frequency range
Exquisite manufacturing process
Advanced SMD surface mount technology and CPU integrated control technology enhance the reliability of the TwinGuard (TG) series UPS performance. It can reliably handle various power issues (power failure, short circuit, overload, high/low voltage, surge), providing protection for the load.
Intelligent, user-friendly design, flexible and easily scalable
Battery is easy to configure, meeting various discharge time requirements.
Smart real-time battery monitoring, battery status at your fingertips
A variety of optional accessories, adaptable to diverse requirements.
| Model | 1K | 1KS | 2K | 2KS | 3K | 3KS | ||
| Capacity | VA/W | 1000VA/800W | 2000VA/1600W | 3000VA/2400W | ||||
| Input Parameters | Input Voltage Range | 115~300VAC | ||||||
| Frequency Range | 40Hz-70Hz | |||||||
| Input Connection | National Standard | |||||||
| Input Harmonic Distortion | < 10% Non-linear Load Factor | |||||||
| Input Power Factor | ≥0.98 | |||||||
| Output Parameters | Output Voltage | 220VAC | ||||||
| Output Precision | ±2% | |||||||
| Output Connection | GB 10A *2 | GB 10A *2 | GB 10A *4 | GB 10A *4 | GB 10A*3 Output Terminal Block | GB 10A*3 Output Terminal Block | ||
| Locking Range | 46-54Hz/54-66Hz | |||||||
| Output Frequency (Battery Mode) | 50/60Hz±0.05Hz | |||||||
| Current Peak Ratio | 3:1 | |||||||
| Output Harmonic Distortion | <4% (linear load) | |||||||
| <7% (non-linear load) | ||||||||
| Output Waveform | Pure sine wave output | |||||||
| Overload Capacity | Mains Power Mode | 105% ~ 150% : 47s ~ 25s 150% ~ 200% : 25s ~ 300ms >200% : 200ms | ||||||
| Battery Mode | ||||||||
| Efficiency | Mains Power Mode | >89% | >90% | >90% | ||||
| Batteries and Charging Parameters | Battery Voltage | 24VDC | 36VDC | 48VDC | 72VDC | 72VDC | 96VDC | |
| Battery Type | 9AH | Based on customer requirements and configurations | 9AH | Based on user requirements and configuration | 9AH | Subject to customer requirements and configurations | ||
| Backup Time | >4.5min | >4.5min | >4.5min | |||||
| Backflush time | 7 hours to 90% recharge | 7 hours to 90% recharge | 7 hours to 90% recharge | |||||
| Charging Current | 1.0A | 6.0A | 1.0A | 6.0A | 1.0A | 6.0A | ||
| Conversion Time | Battery Mode <-> Mains Power Mode | 0ms | 0ms | 0ms | 0ms | 0ms | 0ms | |
| Display | LED | Load / Battery Capacity / Input / Output / Operating Mode | ||||||
| Physical Parameters | (WxHxD)mm | 144x229x345 | 144x229x345 | 190x328x393 | 190x328x393 | 190x328x393 | 190x328x393 | |
| Operating Environment Temperature | 0-40℃ | |||||||
| Environmental Parameters | Operating Environment Humidity | 20-90% (dew-free) | ||||||
| Noise | <45dB at 1 meter | <50dB @ 1-meter distance | ||||||
| Standards and Certifications | IEC61000, IEC62040, GB7260,GB4943 | |||||||
| TLC / Energy-saving Certification / Broadcast Certification | ||||||||
| Communication and Monitoring | RS232 | Standard Configuration | ||||||
| Expandable Slots (Optional) | You can choose from NMC cards, CMC cards, AS400 cards, or USB cards. | |||||||
| EPO (Optional) | Emergency shut-off | |||||||
| Software | Winpower | |||||||