Type: HKL02002-N 318152
Measuring Principle - Capacitance Principle
Output type Min. NPN
Switch Logic Output Polarity NC (Normally Closed)
Operating voltage: 9...36VDC
Load current ≤ 200mA
Short-circuit Protection - Yes
Reverse Polarity Protection Yes
Overload Protection Yes (≤1 A short circuit beyond the environmental temperature range)
Low Side Switch/High Side Switch Current Consumption (no load) <8mA (24V)
Current consumption (no load) For inductive loads, an automatic winding compensation must be installed at the load point
Diodes, such as 1N4007.
Function control timentrol time 2s
Delay time: 7s
Electrical Interface/Cable Lead, PVC Cable, HUBER+SUHNER RADOX GKW-
LW 600V 3x0.5mm² Compliant with TJ/CL313
(CRCC Certified)
Cable Length: 500mm
Mounting Position: Any position (sensor probe must be at least 7mm away from the wall)
Mounting thread M14x1.5
Housing Material: Brass