How to resolve the issue of water leakage in the water tank of a climate-controlled humidity test chamber: 1. First, inspect the water system of the climate-controlled humidity test chamber, observe if the water valve is open too wide, causing excessive water flow. If so, adjusting the water valve to a smaller setting should suffice. 2. Check if the water refilling time of the climate-controlled humidity test chamber is set too frequently, leading to overfilling. If that's the case, increasing the interval between refilling times will reduce the frequency of refilling. 3. Verify if the placement of the climate-controlled humidity test chamber is level, as tilting can be a contributing factor.lThe view angle can cause the dry bulb temperature tube to tilt, which in turn may drip water downwards. At this point, the CASS test chamber manufacturer, it is only necessary to move or shift the equipment to a level road surface. 4. Check if the water level box on the right side of the humidity and temperature test chamber is too high, which may eventually lead to an excessive amount of water entering. If such conditions occur, one only needs to adjust the water level box. Additionally, it is recommended to communicate with the original manufacturer to have a technical staff member sent to the site for repair, as this is an important step for the Gansu CASS test chamber, to prevent any anomalies.
Subtly avoid minor issues in the salt spray test chamber
1. Solution for No-Spray Nozzle: As mentioned in the previous article, I have provided a detailed introduction and feasible solution for the situation where the nozzle does not spray. First, we check if the spray switch is turned on and if there is saltwater in the saltwater tank. Then, we inspect whether the saltwater pipe and air pipe are connected correctly and if the air pipe is blocked, loose, or cracked. After that, we check if the intake pressure and spray pressure are within the experimental specifications.l1. Within the specified range.
2. Solution for water overflow in the sealing groove: This condition occurs when the exhaust pipe of the drain is higher than the exhaust opening, preventing the salt mist from escaping; the solution is to lower the drain's exhaust pipe.
3. Solution for rust on full barrels: This situation usually happens when the operator accidentally adds saltwater to the barrel during the cass test box supply, as saltwater is highly corrosive; even the best stainless steel will rust when exposed to high temperatures for a long time in saltwater conditions.
Programmable恒温恒湿箱
1. Inside box made of imported premiumlHigh-quality SUS304 stainless steel, exterior packaging made of premium materials.lA3 steel plate with electrostatic powder coating, enhancing the texture and overall cleanliness. Equipped with a large observation window with built-in lighting to keep the interior well-lit, cass test chamber quotation, facilitating clear observation of the interior condition.
2. The waterway system pipeline circuit system features a gate-type opening for easy maintenance and inspection. The water tank is located in the lower right section of the control cabinet, equipped with an automatic water shortage protection function, convenient for the operator to replenish water supply.

Cass Testing Box Supply - Tianyi Ruihe Instrument Equipment Co., Ltd. - The Gansu Cass Testing Box is provided by Jiangsu Tianyi Ruihe Instrument Equipment Co., Ltd. With great passion and enthusiasm, Tianyi Ruihe has dedicated itself to the field of testing machines. We are committed to a customer-centric philosophy, creating value for our clients, and winning the market with quality and service. We sincerely hope to collaborate with all sectors of society to achieve success and brilliance together. For related business inquiries, please contact Manager Liu.