Kenjin Group Co., Ltd.VIP

经营范围包含:一般项目:配电开关控制设备制造;电子元器件制造;电力电子元器件制造;电器辅件制造;输配电及控制设备制造;机械电气设备制造;变压器、整流器和电感器制造;电力设施器材制造;仪器仪表制造;电容器及其配套设备制造;五金产品制造;金属链条及其他金属制品制造;电工器材销售;配电开关控制设备销售;电气机械设备销售;智能输配电及控制设备销售;仪器仪表销售;电容器及其配套设备销售;机械零件、零部件销售;电器辅件销售;金属制品销售;五金产品零售;电力设施器材销售;日用百货销售;电力电子元器件销售;非金
Enter Shop

02 Type F outlet mechanism standard electric with secondary wiring (hard interlock)

平台认证
  • Unit Price

    Negotiable

  • Brand

    KenJin Group

  • MOQ

Contact
Leave Msg

Platform Service

Supplier Verified



肯劲集团有限公司

VIP   标王第3年
资料通过中商114认证

Product Details

Specs

Gallery

  • Brand:

    KenJin Group

  • Unit Price:

    Negotiable

  • MOQ:

  • Total:

    0

  • Address:

    ZhejiangWenzhou

  • Delivery:

    3days

  • View More

Description

KJFD-02/MX Intelligent Electric Operation Solution, featuring an MCU chip integrated circuit for intelligent judgment of the closing/opening status of the load switch, performs electric operations on the mechanism according to customer instructions, enabling local closing/opening and remote closing/opening functions. It offers protection against motor overload, undercurrent, or jamming, ensuring the safety of critical components in the mechanism. The controller has a function to signal equipment faults, greatly facilitating daily maintenance.

KJFD-02/NX Standard Electric Operation Scheme, featuring PCB-type terminal integration, electric operation of the mechanism is achieved through relay contacts within the controller. It does not have motor protection or fault alert functions, categorizing it as an economical electric operation solution.

This series of products is factory-shipped after full inspection and meets the requirements of GB 3804-2004 "AC High-Voltage Load Break Switches for 3.6kV-40.5kV," GB 3906-2006 "AC Metal-Enclosed Switchgear and Control Equipment for 3.6kV-40.5kV," and "Combination of High-Voltage AC Load Break Switches and Fuses."

User Operation Instructions

Circuit Closing Operation:

Manual Closing: Secure the mechanism to the panel with the mounting bracket, then insert the handle into the operation shaft at the top of the mechanism and rotate it clockwise by approximately 90°. The mechanism's coiled double spring is compressed to store energy. Press the closing button to release the stored energy in the closing spring, and the main circuit of the load switch completes the closing operation under the power of the mechanism's release.
Electrical Closing: Upon power-up and the closing signal from the mechanism, the controller automatically identifies the on/off position of the load switch and the status of each interlock circuit. If all circuit statuses meet the closing conditions, the controller automatically energizes the closing solenoid, achieving an instantaneous closure of the main circuit of the load switch.

Operations: Disconnecting Switch

Manual disconnector: Press the disconnection button to release energy, and under the power of release, push the load switch to complete the main circuit disconnection action. For electric disconnection, a disconnection signal is provided; the controller will automatically determine the opening and closing position of the load switch and the status of each interlock circuit. If the status of all circuits meets the conditions for disconnection, the controller will activate the disconnection solenoid to release energy, achieving the main circuit disconnection of the load switch. The mechanism can perform main circuit closing or grounding closing operations when in the disconnection state.

Grounding, Closing, and Opening Contacts:

Grounding Closure: Insert the mechanism handle into the grounding operation shaft at the bottom of the mechanism, rotate clockwise approximately 90°. The grounding energy storage spring releases energy instantly upon compressing past the midpoint, pushing the grounding switch to complete the grounding closure. At this point, the mechanism interlock locks, preventing the main circuit closure.
Grounding Disconnector: Insert the mechanism handle into the grounding operation shaft at the bottom of the mechanism, rotate counterclockwise approximately 90°. As the grounding accumulator spring compresses past the midpoint, it releases energy instantaneously to push the grounding switch into the disconnected position. At this point, the mechanism interlock is engaged, allowing for operation of the load switch's closing and opening functions.

Actuator external and installation dimensions


Disclaimer:Info provided by user, user liable for authenticity, accuracy & legality. Zhongshang114 assumes no liability.

Tip:Confirm supplier qualification & quality before purchase to avoid risks.

Unit Price Negotiable
Inquiry None
Delivery ZhejiangWenzhou3dayswithin
Brand KenJin Group
Origin Zhejiang Wenzhou
Is Customization Available? Is
Is Importing No
Expiry Long Valid
Update 2023-10-20 16:10
Gallery

Kenjin Group Co., Ltd.Published by02 Type F outlet mechanism standard electric with secondary wiring (hard interlock)Gallery Lib

Contact Merchant



Join

Successful Enterprise Join, Enjoy Multiple Privileges

Join Hotline:4006299930

Please scan with mobile phone

Customer Service

Service Hotline:4006299930

Official Account

WeChat Official Account, Get Business Opportunities

Scan to follow WeChat

Top