Fountains are a common landscape feature. While enjoying them, we must also understand that their maintenance can be challenging. Therefore, it's important to protect them regularly to extend the lifespan of the fountain equipment. Here are four methods compiled by the Henan Fountain Equipment editor for your reference:

1. Fountain Equipment: The fountain equipment should not exceed 15 degrees in temperature, the chromaticity should not differentiate between water of different colors, the turbidity should not exceed 10 degrees, and be invisible to the naked eye. The impurity content should not exceed 0.1%, with impurities not larger than 0.2mm, and a chloride ion content not exceeding 400 ppm. The pH value should be within the range of 6.5 to 8.5. Even during the periodic use of the water斗 equipment, when the nozzle has a demand, the recycled water should be filtered for treatment. Depending on the evaporation, color changes, leaks, wastewater, if any loss, it is advisable to use a speed of 5% to 10% typically of the circulating water system to compensate.

Henan Fountain Equipment
2. Nozzles: Regular maintenance and protection of nozzles are essential. The unit should pay attention to the tightness of the nozzle connection with the pipeline. The nozzle should be wrapped with a layer of Teflon tape around the silk thread to prevent leaks, ensure the spraying effect, and make sure the nozzle fits well together.
3. Underwater Lights: Since underwater lights are prone to damage in fountain equipment components, it is crucial to have a well-protected light at all times. The lights are waterproofed using heat shrink tubes and hot melt adhesives; when assembling the lights with tight connections, ensure the lights are not loose; for pipe welding lights, the welding of the light panels must be securely tightened to avoid the process of light quantity reduction; after assembly, the lights should be tested in a 5% saltwater solution for 72 hours, and the measured values after qualification can be used.

4. Pumps: Common issues with pumps are often related to lack of water, either directly or with insufficient water. The motor will not start with a humming sound, and the insulation resistance of the winding will be low to ground. The main external reasons for these issues are blocked pipeline to motor start, pipe破裂, filter water resistance, water inlet performance, foreign objects in the impeller. At this point, we must identify the cause of the fault location... Potential sorting issues may include blockages, fixed wiring that can replace imported bearings, etc., to ensure the pump operates normally.