The paint mist is drawn into the cyclone tower by the suction force of the negative pressure fan, where it undergoes a gas-liquid emulsification reaction with the mist, whirlwind, and water through high-speed rotation. The high-speed operation of the pneumatic mixing device ensures thorough mixing of the paint mist with the rotating liquid, achieving paint separation under centrifugal force. Inside the cyclone spray tower, a water pump circulates water, which is then emitted through non-clogging spiral nozzles at the bottom of the water-separation layer. The dust particles separated from the paint mist settle at the bottom of the water tank, while the separated gas enters the water-separation layer with environmental-friendly filling material, and then proceeds to the subsequent waste gas treatment equipment. The paint mist purification rate after treatment by the cyclone mixing spray tower can meet national emission standards.
Application field of the Cyclone Hybrid Spraying Tower:
The Cyclone Tower has multiple applications: acid mist removal, odor control, sulfur removal, dust removal, oil mist removal, etc. It is widely used in the pretreatment of industrial waste gas purification and dust removal. It also handles various harmful gases such as H2S, SOX, NOX, HCI, NH3, CI2, and more. Odor control devices for waste transfer stations or landfills, and wastewater treatment plants. Process exhaust treatment for the semiconductor optoelectronics industry. Waste gas treatment for leachate storage ponds in landfill sites. Waste gas treatment for incinerators and industrial furnaces.