N5242B
Key Features and Technical Specifications
10 MHz to 26.5 GHz
2 or 4 ports, with 2 built-in signal sources.
132d system dynamic range and 130dB receiver dynamic range, 100,001 points, 200 channels, 15 MHz IF bandwidth
High output power (+138dBm), low harmonic (-60dBc) and wide power sweep range (38 dB)
Dynamic Accuracy: Utilizing 0.1 dB compression and +13 dBm input power at the test interface
At a mid-frequency bandwidth of 10 Hz, there is only a low noise floor of -114 dBm.
Selection Options:
Test Unit:
N5242B-200 2-port, single signal source
N5242B-224 - Dual Port, with Signal Source, Synthesizer, and Mechanical Switches
N5242B-400 4-port, dual signal source
N5242B-423 4-port, with internal synthesizer and mechanical switch
N5242B-020 - Intermediate Frequency Input for Antennas and Millimeter Waves
N5242B-021 - Add Pulse Modulator to Signal Source 1
N5242B-022 - Add Pulse Modulator to 2 Signal Sources
N5242B-025 - Four Basic Built-in RF Pulse Generators
N5242B-026 - Four High-Grade Built-In RF Pulse Generators
Power Configuration:
N5242B-219 - PNA-X Extender Power and DC Offset for Dual Port Test Set
N5242B-419 PNA-X Extender Power and DC Bias for Four-Port Test Set
N5242BS-H85 High-Power Configurable (for 2 or 4 Ports) (Dual Port requires 200 options, 4 Port requires 400 options)
Measurement Application Software:
N5242B-008 Pulse RF Measurement Function
N5242B-010 Time Domain Measurement
N5242B-011 - Utilizing TDR for Enhanced Time-Domain Analysis
N5242B-028 Measure and calibrate noise figure with standard receiver (Option 080 required)
N5242B-029 Add Low-Noise Receiver (require option 219, 224, 419, 423 or H85, and option 080)
N5242B-080 Frequency Offset
N5242B-082 Scalar Mixter/Converter Measurement (requires option 080)
N5242B-083 Vector and Scalar Calibration Inverter Measurement (requires option 080)
N5242B-084 Embedded LO Test (at least one of the following options is required: 028, 029, H29, 082, 083, 086, or 087)
N5242B-086 Amplification Compression Application (GCA) (Recommended Option 219, 419, or H85)
N5242B-087 Intermodulation Distortion (IMD) Application (requires option 224 or 423)
N5242B-460 Integrated True Analog Stimulus Application Software (iTMSA) (requires option 400)
N5242B-551 N Port Function
Nonlinear Vector Network Analysis
N5242B-510 Nonlinear Component Characterization (Full Bandwidth) (requires Options 419 and 080 or 400 H85 and 080)
N5242B-514 Nonlinear X Parameter (requires options 423 and 510)
N5242B-518 Nonlinear Pulse Envelope Domain (requires options 021 and 025, and either option 510 or 514)
N5242B-520 Arbitrary Load Impedance X Parameter (requires option 514)
N5242B-118 PNA-X Series Fast Continuous Wave Scan
N5242B-088 Signal Source Phase Control
N5242B-089 Differential and I/O Device Application Software
N5242B-007 Auto Clamp Removal
N5242B-015 Dynamic Measurement Uncertainty for S Parameters
N5242B-090 Spectrum Analyzer (Option 216 or 416 required)
N5242B-900A 8.5GHZ
N5242B-901A 13.5GHZ
N5242B-902A 26.5GHZ
N5242B-904A 43.5GHZ
N5242B-905A 50GHZ
N5242B-907A 67GHZ
N5242B-093 Spectrum Analyzer Frequency Range Extended to 120 GHz (requires N5261A/62A or N5292A Millimeter Wave Controller)
N5242B-094 Spectrum Analyzer Frequency Range Extended to Over 120 GHz (requires N5261A/62A or N5292A Millimeter Wave Controller)