Model: UL246-4 (Parallel)
Introduction: Suitable for measuring, monitoring, and controlling cables used in machine tool manufacturing, installation projects of complete sets of equipment, power stations, heating and air conditioning systems, refrigeration equipment, office automation equipment, and data processing systems.
Application Scope
Suitable for measuring, monitoring, and controlling cables used in machine tool manufacturing, installation projects for complete sets of equipment, power stations, heating and air conditioning systems, refrigeration equipment, office automation equipment, and data processing systems.
Product Features
Heat-resistant and flame-retardant, with excellent insulation properties and stable chemical performance. The use of innovative aluminum foil mylar with tin-plated copper wire woven double shielding effectively resists electromagnetic interference.
Application Standard: UL 758
Cable structure
Conductor: Multi-strand fine copper wire/tinned copper wire, strong corrosion resistance
Insulation: Special hard, heat-resistant, flame-retardant PVC insulation
Color: Meets UL758
Internal Shielding: Aluminum Foil Mylar Encapsulation
Drainage lines: (Optional) Same specification as conductors for drainage effect, facilitating harness shielding processing.
Wiring: Tin-plated copper wire braided shielding (optional).
Sheath: Mixed 80°C heat-resistant flame-retardant PVC sheath, passed VW-1 flame-retardant test
Black, green, orange, purple; others not listed can be produced upon request.
Detailed specifications
Rated Voltage: 300V
Test Voltage: 2000V
Operating Temperature Range:
Fixed Installation: -15℃ to +80℃
Portable Installation: -5°C to +80°C
Minimum bend radius:
Fixed Installation: 4x Cable Outer Diameter
Portable Installation: 15x Cable Outer Diameter