Cables, wires, compensating wires, heating cables, instruments, meters, switc...
产品Price 8.60/Rice
最小起订Quantity:100 Rice 供货总Quantity: 99000 Rice
Conductor |
|
Insulation |
F46 |
Protective Cover |
F46 |
Shielded |
Copper wire, Tin-plated copper wire |
Appearance |
Flat, Round |
Temperature |
-65 to 200℃ |
KFFP 2x1.0mm2 High-Temperature Control Cable Standard TICW/03-2009 Section 1: Illustration of High-Temperature Control Cable High-Temperature Control Cable Applications High-temperature control cables are used for control wiring of electrical equipment and appliances, with a long-term operating temperature of 200°C. The bend radius should not be less than 8 times the cable outer diameter, and cables with armor or shielding should have a bend radius not less than 15 times the cable outer diameter. Suitable for high-temperature environments in industrial and mining enterprises, energy and transportation departments, and for control and protection circuits operating at alternating current rated voltages of 450/750V or below. Section 3: High-Temperature Control Cable Models and Composition P1 Tin-plated wire shielding, P2 Copper strip shielding, P3 Aluminum/plastic composite film shielding, 9 Steel wire braided armor For example: Copper-core fluoroplastic insulated fluoroplastic sheathed copper wire screening control flexible cable, for mobile laying, rated voltage 450/750V, 19 cores, 1.5mm². KFFRP-450/750V 19x1.5mm2 Copper-core Fluoroplastic Insulated Fluoroplastic Sheathed Control Cables, for Fixed Installation, Rated Voltage 450/750V, 7 cores, 1.5mm² KFF-450/750V 7x1.5mm2 Section 4: High-Temperature Control Cable Specifications Model Conductor Nominal Cross-Sectionmm2 0.5 0.75 1.0 1.5 2.5 4 6 Core Count KFF KFFP - 2-19 2-12 KFFP2 - 2-19 2-12 KFFR 2-19 2-12 KFFRP 2-19 2-12 KFF9F - 2-19 2-12 Note: The recommended series of cores are:2, 3, 4, 5, 7, 8, 10, 12, 14, 16, 19 cores Section 5: Nominal Insulation Thickness of High-Temperature Control Cables Conductor Nominal Section Area mm2 Insulation Nominal Thicknessmm Conductor Nominal Cross-Section mm2 Insulation Nominal Thicknessmm 450/750V 0.6/1Kv 450/750V 0.6/1Kv 0.5,0.75 0.30 0.35 2.5 0.35 0.40 1 0.30 0.35 4 0.45 0.50 1.5 0.30 0.40 6 0.45 0.50 Section 6: Nominal Thickness of High-Temperature Control Cable Sheath Assumed outer diameter prior to packing sleeve compressiond mm Nominal Thickness of the Jacket mm Assumed Outer Diameter Prior to Squeezing Package Sheathd mm Grommet Nominal Thickness mm d≤10 10<d≤16 0.6 0.7 16<d≤25 25<d≤30 0.9 1.1 Note: Control cables with large-diameter fluoroplastic insulated sheath are not considered at this time. Note:High-temperature control cable insulation sheath materials are all made of virgin material: polytetrafluoroethylene ethylene propylene (PFA, FEP, F46, Teflon, fluoro plastics, Teflon). The products feature resistance to high and low temperatures from -65°C to 200°C, -65°C to 260°C, oil resistance, corrosion resistance, acid and alkali resistance, and aging resistance.


Phone Consultation