Cables, wires, compensating wires, heating cables, instruments, meters, switc...
产品Price 9.50/Rice
最小起订Quantity:100 Rice 供货总Quantity: 99000 Rice
Conductor |
|
Insulation |
F46 |
Protective sleeve |
F46 |
Shield |
Copper wire, tin-plated copper wire |
Appearance |
Round |
Temperature |
-65 to 200℃ |
KFFP High Temperature Control Cable TICW/03-2009 standard Section 1: Diagram of High-Temperature Control Cable High-Temperature Control Cable Applications High-temperature control cables are used for the control wiring of electrical equipment and appliances. They operate at a long-term working temperature of 200°C, with a bend radius not less than 8 times the cable's outer diameter. Cables with armor or shielding should have a bend radius not less than 15 times the cable's outer diameter. These cables are suitable for high-temperature environments in industrial and mining enterprises, energy and transportation departments, and for controlling and protecting circuits at AC rated voltages below 450/750V. Fluoroplastic insulated and sheathed control cables are applicable. Section 3: High-Temperature Control Cable Models and Composition P1 Tin-plated wire shielding, P2 Copper strip shielding, P3 Aluminum/plastic composite film shielding, 9 Steel wire braided armor For example: Copper-core Fluoroplastic Insulated Fluoroplastic Sheathed Copper Wire Shielded Control Flexible Cable, for mobile laying, rated voltage 450/750V, 19 cores, 1.5mm². KFFRP-450/750V 19x1.5mm2 Copper-core Fluoroplastic Insulated Fluoroplastic Sheathed Control Cable, for fixed laying, rated voltage 450/750V, 7 cores, 1.5mm². KFF-450/750V 7x1.5mm2 Section 4: High-Temperature Control Cable Specifications Model Conductor Nominal Section Areamm2 0.5 0.75 1.0 1.5 2.5 4 6 Core Count KFF KFFP - 2-19 2-12 KFFP2 - 2-19 2-12 KFFR 2-19 2-12 KFFRP 2-19 2-12 KFF9F - 2-19 2-12 Note: The recommended series of cores are:2, 3, 4, 5, 7, 8, 10, 12, 14, 16, 19 cores V.High-Temperature Control Cable Insulation Nominal Thickness Conductor Nominal Section Area mm2 Insulation Nominal Thicknessmm Conductor Nominal Section Area mm2 Insulation Nominal Thicknessmm 450/750V 0.6/1Kv 450/750V 0.6/1Kv 0.5,0.75 0.30 0.35 2.5 0.35 0.40 1 0.30 0.35 4 0.45 0.50 1.5 0.30 0.40 6 0.45 0.50 Six.High-Temperature Control Cable Sheath Nominal Thickness Assumed outer diameter before packing sleeve compressiond mm Sleeve Nominal Thickness mm Assumed outer diameter prior to packing sleeve compressiond mm Housing nominal thickness mm d≤10 10<d≤16 0.6 0.7 16<d≤25 25<d≤30 0.9 1.1 Note: Large diameter fluoroplastic insulated sheath control cables are not considered at this time. Note:High-temperature control cable insulation sheath materials are all made of virgin material: polytetrafluoroethylene ethylene (PFA, FEP, F46, Teflon, fluoroplastic, Teflon). The product features resistance to extreme temperatures of -65~200°C, -65~260°C, oil resistance, corrosion resistance, acid and alkali resistance, and aging resistance.


Phone Consultation