详情描述
I. Technical Specifications
Standard: GB/T 8018, ASTM D 525
2. Pressure Measurement Range: 0 ~ 1600 Kpa
3. Temperature Range: 0.0°C to 100°C
Resolution: 0.1℃
5. Temperature Control Accuracy: ±0.1℃ within 100℃
6. Temperature Sensor: PT100
7. Test Tub: Metal Tub
8. Test Holes: 2, capable of testing two samples simultaneously
9. Power Supply: AC 220V ±10%, 50Hz
10. Total Power: ≤ 1500W
11. Dimensions: 550mm x 350mm x 500mm
Instrument Weight: 40 kg
13. Environmental Temperature: 5℃ to 40℃
14. Relative Humidity: ≤ 85%
II. Performance Features
1. Accuracy:
(1) High temperature control accuracy of the instrument: 100±0.1°C, with temperature calibration function for enhanced accuracy and reduced experimental errors.
(2) The instrument features pressure calibration functionality, providing more precise pressure display and control.
(3) The instruments feature embedded systems and modular design, ensuring stable performance and accurate detection.
(4) The oxygen bomb used for instrument testing features an integrated design, greatly shortening the pipeline for oil and gas pressure testing, resulting in more accurate pressure detection.
(5) Utilizing oil and high-temperature-resistant seals ensures excellent oxygen bomb sealing during testing, leading to more reliable results.
2. Automation:
The instrument features a 7-inch color LCD touchscreen with real-time display of pressure and time curves.
(2) The instrument features both automatic and manual oxygen charging and discharging capabilities, complete with a pressure-reducing valve to ensure stable and accurate pressure. Users can conveniently and quickly complete the oxygen charging and discharging process.
(3) The instrument features an automatic leak detection function. After being pressurized to the target level, it automatically determines if there is a leak. Once the detection is complete, a dialog box prompts the user about the presence of a leak, significantly reducing human error.
(4) One-click activation, automatic detection, automatic identification of inflection points, automatic storage, automatic printing
(5) The instrument features an end-stop function, allowing users to set the stop time online according to sample requirements, which can save time and energy.
(6) The instrument can cyclically store 10,000 test results. Equipped with a thermal printer, it offers fast printing speed and noiseless operation.
Safety:
(1) The instrument heating section has been modified from traditional water bath to metal bath, ensuring no contamination and no need for water replenishment.
(2) The housing is equipped with an overpressure automatic relief device; in the event of excessive pressure, the instrument will automatically release pressure, ensuring safety and reliability.
(3) The instrument features a well-designed thermal insulation system, which saves energy and prevents operators from being scalded.
(4) The instrument is equipped with an overheat protection device, which will automatically shut off the heating system when the temperature exceeds the set limit, enhancing the instrument's safety.
(5) The instrument features a set oxidation time function. According to national standards, if the sample undergoes slow oxidation, upon reaching the set time, the instrument automatically calculates the highest to lowest pressure drop at that time, which serves as experimental data.
(6) The instrument is equipped with a pressure release valve. After oxygen filling is complete, the oxygen in the pipeline can be vented. It also comes with an oxygen exhaust pipe and a connecting adapter, allowing oxygen to be discharged outdoors safely without any noise.