- AllProduct Category
-
Explosion-proof Electric/Steam/Hot Water Heater Blowers
Humidifier and Dehumidifier in One
Rotary Dehumidification Unit - Customized
Mobile Air Conditioner/Portable Air Cooler
Fan Coil Unit/Air Handling Unit
Smart Dehumidifier Unit
Explosion-proof Modular Air Handling Unit / Swimming Pool Dehumidifying Air Handling Unit
Explosion-Proof Rooftop AC Series
Explosion-Proof Cold Water (Hot Water) Unit Series
Explosion-Proof Oven
Explosion-proof Air curtain Machine
Explosion-proof Temperature and Humidity Control Unit/Non-standard Temperature and Humidity Control System
Industrial Air Conditioning / Explosion-proof Industrial Air Conditioning
Cabinet Air Conditioners / Explosion-Proof Cabinet Air Conditioners
Explosion-proof Fan Coil Unit
Explosion-Proof Refrigerator
Explosion-proof Air Conditioner
Explosion-Proof Dehumidifier
Humidifier/Blast-Proof Humidifier
Dehumidifier


详情描述
Product Specifications
Brand: YingTeng
Product Model: YTK-37E-01
Cooling Capacity: 3745W
1.5匹
Voltage/Frequency: 220V/50Hz
Power: 1500W
Control Type: Touchscreen Control
Airflow: 600 m³/h
Motor Brand: Zhongshan Great Fortune
Temperature Range: 16-30℃
Fan: Cold 70W x 1 / Hot 70W x 1
Timer function: On/Off every 24 hours
Wind Speed Settings: Low and High Speed
Pipe Diameter: Cold 120mm / Hot 180mm
Quantity: Twin barrels (blue and white)
Wind Distance: 6 meters
Tank Capacity: 6L
Operating Temperature: 5-45°C
Body Size: 440×500×945mm
Customizable Features: Purification, Antivirus, Tracking, Stainless Steel, Corrosion Resistance between Two Devices
Portable Air Conditioner Usage Instructions
Packaging Instructions: After unpacking, lift the machine out as a whole. The air ducts and accessories are located on both the upper and lower trays; please note this.
2. 3-Minute Delay: There is a 3-minute delay upon startup, as well as after switching to ventilation/cooling mode, or moving the water tank.
3. Plug-in Notice: It is recommended to use a 16A outlet and plug it directly into the wall. *It is best not to use a power strip (some power strips have too small current capacity, which may overheat during use and is unsafe).
4. Power Voltage: For unstable or insufficient voltage below 220V, a voltage stabilizer must be added, or a 1P, 1.5P, 2P or higher compressor that cannot be powered should be selected (the machine shows cooling, but no cold air is produced, or the cooling stops after a few minutes of vibration, which is also a power voltage issue; the power cable needs to be 2.5 square mm).
5. Normal Operation Check: Blue and white lines moving on the screen indicate that the compressor has started and cooling has commenced, which is normal operation. If they do not move, please check if the ventilation mode is turned on or if the water level indicator shows full.
6. Customized Selection: Press "+" to switch between cooling/ventilation modes, press "-" to adjust between high and low fan speeds.
7. Water Full: Indicate water is full, please check the water tank and pour out the excess; if there's no water or it's not full, the position is incorrect, just adjust it (occasionally, even if it doesn't show water full, if the blue and white line doesn't move and the refrigeration doesn't start, it's also because the water tank is not properly placed).
8. Watering: You'll need to refill the water every day or so, it's recommended to do so before leaving work or before turning on the machine in the morning; directly draining into the floor drain with an external water pipe is also acceptable.
9. Filter Mesh: Regularly clean the filter mesh; for areas with heavy dust, clean it every 2-3 days (the front panel can be lifted to detach the filter mesh).












