- AllProduct Category
-
Explosion-proof Electric/Steam/Hot Water Heater Blowers
Humidifier and Dehumidifier in One
Rotary Dehumidification Unit - Customized
Mobile Air Conditioner/Portable Air Cooler
Fan Coil Unit/Air Handling Unit
Smart Dehumidifier Unit
Explosion-proof Modular Air Handling Unit / Swimming Pool Dehumidifying Air Handling Unit
Explosion-Proof Rooftop AC Series
Explosion-Proof Cold Water (Hot Water) Unit Series
Explosion-Proof Oven
Explosion-proof Air curtain Machine
Explosion-proof Temperature and Humidity Control Unit/Non-standard Temperature and Humidity Control System
Industrial Air Conditioning / Explosion-proof Industrial Air Conditioning
Cabinet Air Conditioners / Explosion-Proof Cabinet Air Conditioners
Explosion-proof Fan Coil Unit
Explosion-Proof Refrigerator
Explosion-proof Air Conditioner
Explosion-Proof Dehumidifier
Humidifier/Blast-Proof Humidifier
Dehumidifier


详情描述
Product Specifications
Brand: YingTeng
Product Model: YTK-75E-01
Cooling Capacity: 7315W
Yards: 3 yards
Voltage/Frequency: 220V/50Hz
Power: 3350W
Control Type: Touchscreen Control
Airflow: 2000 m³/h
Motor Brand: Zhongshan Hengda
Temperature Range: 16-30℃
Fan: Cold 50W x 2 / Hot 70W x 2
Timer Function: 24H On/Off
Wind Speed Settings: High and Low Speeds
Pipe Diameter: Cold 120mm / Hot 180mm
Quantity: Three tubes (blue and white)
Wind Distance: 6 meters
Tank Capacity: 6L
Applicable Temperature: 5-45℃
Body Dimensions: 630×560×1260mm
Customizable Features: Purification, Antivirus, Tracking, Stainless Steel, Corrosion Resistance between Two Devices
Portable Air Conditioner Usage Precautions
Packaging Instructions: After unpacking, lift the machine out whole. The air ducts and accessories are located on both the top and bottom trays; please note.
2. 3-Minute Delay: There is a 3-minute delay upon startup, and also after switching to ventilation/cooling mode or moving the water tank.
3. Power Plug Notice: It is recommended to use a 16A outlet and plug it directly into the wall. *Avoid using extension cords (some extension cord wires have insufficient current, which can overheat during use and is not safe).
4. Power Voltage: For unstable or insufficient voltage below 220V, a voltage stabilizer must be added, or a 1P, 1.5P, 2P, or higher compressor that cannot be powered should be selected (the machine displays cooling, but no cold air is produced, or the cooling stops after a few minutes of vibration, which is also a power voltage issue; the power cable must be 2.5 square mm).
5. Normal Operation Check: Blue and white lines moving on the screen indicate the compressor is on and cooling has started, which is normal operation; if they are not moving, please check if the ventilation mode is activated or if the water level indicator shows full.
6. Personalized Selection: Press "+" to switch between cooling/ventilation modes, press "-" to adjust between high and low wind speeds.
7. Water Full: Display indicates water is full, please check the water tank and pour out the excess; if there is no water or it's not full, the position may be incorrect, simply adjust it (occasionally, no water full display, but the blue and white line does not move and cooling doesn't start, may also indicate the tank is not properly placed).
8. Watering: It needs to be watered once every day or so. It is recommended to water before leaving work or before turning on the machine at the start of the shift; draining directly into the floor drain via an external water pipe is also acceptable.
9. Filter Screen: Regularly clean the filter screen; for heavy dust conditions, clean it every 2-3 days (the front panel can be lifted to detach the filter screen).