Explosion-proof Electric/Steam/Hot Water Heater Blowers
Humidifier and Dehumidifier in One
Rotary Dehumidification Unit - Customized
Mobile Air Conditioner/Portable Air Cooler
Fan Coil Unit/Air Handling Unit
Smart Dehumidifier Unit
Explosion-proof Modular Air Handling Unit / Swimming Pool Dehumidifying Air Handling Unit
Explosion-Proof Rooftop AC Series
Explosion-Proof Cold Water (Hot Water) Unit Series
Explosion-Proof Oven
Explosion-proof Air curtain Machine
Explosion-proof Temperature and Humidity Control Unit/Non-standard Temperature and Humidity Control System
Industrial Air Conditioning / Explosion-proof Industrial Air Conditioning
Cabinet Air Conditioners / Explosion-Proof Cabinet Air Conditioners
Explosion-proof Fan Coil Unit
Explosion-Proof Refrigerator
Explosion-proof Air Conditioner
Explosion-Proof Dehumidifier
Humidifier/Blast-Proof Humidifier
Dehumidifier


详情描述
The Yingteng FP series fan coil units incorporate advanced technology from similar products domestically and internationally. In accordance with national standards, after numerous trials and tests, they have efficiently completed a series of technical design improvements. As a result, they offer superior performance, wide applications, a complete range of types, high efficiency, and low noise. The series includes horizontal concealed, horizontal exposed, vertical concealed, vertical exposed, and cassette units. When paired with fresh air handling units, they are widely used in hotels, hospitals, office spaces, high-end conference halls, exhibition halls, and other low-noise environments, making them an ideal terminal device for centralized air conditioning systems.
Model: FP68 (BG)
Brand: YingTeng
Airflow (m³): 680
Cooling Capacity (W): 3600
Heat (W): 5400
Noise dB(A): ≤41
Cold Water Supply Temperature: 7℃-12℃
Hot Water Supply Temperature: 40℃-60℃
Working Pressure (KPa): 1.6
Static Pressure: 30Pa/50Pa
Power Supply: 220V/50Hz
In and Out Pipe: ZG3/4
Condensate Drain Pipe: ZG3/4
Dimensions (Length x Width x Height mm): 880 x 190 x 300
Note: The data in the table is the measured value under the test conditions specified by the national standard for "Fan Coil Units" (GB/T19232-2003).
Supply Cold Operating Conditions: Inlet Air Dry Bulb Temperature DB=27℃, Wet Bulb Temperature WB=19.5℃
Cold water inlet temperature: 7℃, outlet temperature: 12℃.
Heating operation parameters: Imported dry bulb air temperature DB = 21°C, incoming water temperature 60°C.
2. Noise Measurement: Values measured at 1 meter forward and upward from the front of the unit within an anechoic chamber.
3. Standard configuration of vertical concealed units features an outdoor static pressure of 12 Pa.
4. Water resistance refers to the water resistance at the rated flow rate; input power refers to the input power at the high airflow setting.
5. When selecting a combination of cold and hot twin-coil unit, refer to the main technical parameters in the table above. One row of heat is approximately 40% of three rows of heat, low static...
The air volume loss of the pressurizing unit is approximately 10%, and the static pressure loss of the high static pressure unit is about 20%.
Product Features
Vertical and horizontal surface-mounted, vertical concealed, ceiling-mounted, cabinet-style, wall-mounted, and more series available.
Low overall height, saving building space.
High cooling (heating) capacity, low noise, three-speed motor for adjustable air volume, meets various usage requirements.
The entire unit is made of hot-dip galvanized steel, copper tubes, and aluminum fins, offering strong corrosion resistance.
The drip pan is fully molded, and the insulation employs a whole-pressure bonding technique, eliminating concerns about condensation.
Equipped with exhaust and drain functions, ensuring thorough heat exchange and preventing pipeline cracking due to freezing.
The cooler is made of copper tubes and high-efficiency aluminum fins, mechanically drawn together.
The unit employs an efficient aluminum finned heat exchanger with a low-noise fan, enhancing heat exchange and maximizing the heat exchanger's thermal transfer efficiency.
Precision design allows for the left and right configurations to be selected at will for ordering. An automatic temperature control unit can be optionally provided for constant temperature control of the controlled area; (temperature control unit to be ordered separately)
The motor is an energy-saving fixed phase capacitor motor, equipped with imported high-precision steel ball bearings that are self-lubricating. The motor shafts are all heat treated and chrome-plated for durability, with easy disassembly at the fixed points. The motor lead wires are protected by metal hoses, meeting international standards.
The static pressure of the standard coiled discharge outlet is 0~12Pa, while the static pressure of the residual pressure discharge outlet is 30Pa (or ≤50Pa), with the code H.
The water tray and insulation are molded, with an overall adhesive bonding process, ensuring strength, durability, and no weld marks. The design is aesthetically pleasing and lightweight, with no condensation or dripping. The exposed piping is made from sheets produced by Baosteel Shanghai, which are surface-plated, while the concealed piping is made from galvanized steel or fingerprint-resistant steel.
The coiled tube material is made from seamless copper tubes with corrugated aluminum fins, formed by hydraulic or mechanical expansion. The interior of the coil box is lined with sound-absorbing and insulating materials, with the copper tubes arranged in an interlaced pattern, offering exceptional heat transfer performance and minimal air resistance.