- AllProduct Category
-
Explosion-proof Electric/Steam/Hot Water Heater Blowers
Humidifier and Dehumidifier in One
Rotary Dehumidification Unit - Customized
Mobile Air Conditioner/Portable Air Cooler
Fan Coil Unit/Air Handling Unit
Smart Dehumidifier Unit
Explosion-proof Modular Air Handling Unit / Swimming Pool Dehumidifying Air Handling Unit
Explosion-Proof Rooftop AC Series
Explosion-Proof Cold Water (Hot Water) Unit Series
Explosion-Proof Oven
Explosion-proof Air curtain Machine
Explosion-proof Temperature and Humidity Control Unit/Non-standard Temperature and Humidity Control System
Industrial Air Conditioning / Explosion-proof Industrial Air Conditioning
Cabinet Air Conditioners / Explosion-Proof Cabinet Air Conditioners
Explosion-proof Fan Coil Unit
Explosion-Proof Refrigerator
Explosion-proof Air Conditioner
Explosion-Proof Dehumidifier
Humidifier/Blast-Proof Humidifier
Dehumidifier


详情描述
The Yingteng FP series fan coil units incorporate advanced technologies from similar products both domestically and internationally. Designed in accordance with national standards and after numerous trials and measurements, they have efficiently completed a series of technical design improvements. As a result, they offer superior performance, wide applications, a complete range of types, high efficiency, and low noise. The series includes horizontal concealed, horizontal exposed, vertical concealed, vertical exposed, and cassette units. When paired with air handling units, they are extensively used in low-noise environments such as hotels, hospitals, office spaces, high-end conference halls, and exhibition halls, making them ideal terminal devices for centralized air conditioning systems.
Product Specifications
Model: FP51 (KC)
Brand: YingTeng
Airflow (m³): 510
Cooling Capacity (W): 2700
Heat (W): 4050
Noise db(A): ≤39
Cool Water Supply Temperature: 7°C - 12°C
Hot Water Supply Temperature: 40℃-60℃
Working Pressure (KPa): 1.6
Static Pressure: 30Pa/50Pa
Power Supply: 220V/50Hz
In and Out Pipe: ZG3/4
Condensate Drain Pipe: ZG3/4
Dimensions (Length x Width x Height mm): 680 x 680 x 390
Note: The data in the table is the measured value under the test conditions specified in the national standard for "Fan Coil Units" (GB/T19232-2003).
1. Cold supply conditions parameters: Inlet dry bulb temperature DB=27℃, wet bulb temperature WB=19.5℃.
Inlet cold water temperature: 7℃, outlet water temperature: 12℃.
Heating工况parameters: Inlet air dry bulb temperature DB=21℃, incoming water temperature 60℃.
2. Noise Measurement: Values measured at 1-meter distances above and below the front of the unit, within the anechoic chamber.
3. The standard configuration of the vertical concealed unit has an external static pressure of 12 Pa.
4. Water resistance refers to the resistance at the rated flow rate; input power refers to the input power at high airflow.
5. When selecting a combination cold and hot twin-coil unit, refer to the main technical parameters in the table above. One row of heat is approximately 40% of three rows of heat, low static...
Airflow loss in the press unit is approximately 10%, and static pressure loss in the high-pressure unit is about 20%.
Product Features
Available in horizontal surface-mounted, horizontal concealed, vertical surface-mounted, vertical concealed, ceiling-mounted, cabinet-style, wall-mounted, and more series.
Low overall height, saving building space.
High cooling (heating) capacity, low noise, three-speed motor for adjustable air volume, catering to various usage requirements.
The entire unit is made of hot-dip galvanized steel, copper tubes, and aluminum fins, featuring strong corrosion resistance.
The drip pan is fully molded, and the insulation uses a full-pressure bonding technique, eliminating concerns about condensation.
Equipped with exhaust and drain functions, ensuring thorough heat exchange and preventing pipeline freezing and cracking.
The condenser is made of copper tubes and high-efficiency aluminum fins, mechanically expanded.
The unit features an efficient aluminum finned heat exchanger and a low-noise fan, enhancing heat exchange and maximizing the heat exchanger's thermal transfer efficiency.
Precision design allows for the left and right configurations to be ordered at your convenience. Upon request, an automatic temperature control unit can be customized for constant temperature control of the controlled area; (temperature control unit to be ordered separately)
The motor is an energy-saving fixed phase capacitor motor, equipped with imported high-precision steel ball bearings that are self-lubricating. The motor shafts are all heat-treated and hard-chromium coated for durability, with easy disassembly at the fixed points. The motor leads are protected by metal hoses, compliant with international standards.
Standard coil outlet static pressure is 0~12Pa, while the residual pressure outlet static pressure is 30Pa (or ≤50Pa), with the code H.
The water pan and insulation are made by molding, featuring an overall adhesive process for durability without weld marks. The appearance is aesthetically pleasing and lightweight, with no condensation or dripping. The exposed pipe is made from sheet metal produced by Baosteel Shanghai, with a spray-painted surface treatment, while the concealed pipe is made from galvanized sheet or fingerprint-resistant material.
The coiled material is made from seamless copper tubes with corrugated aluminum fins, formed by hydraulic or mechanical expansion. The coil box is lined with sound-absorbing and insulating materials, featuring copper tubes arranged in an interlaced pattern, which offers exceptional heat transfer performance and low air resistance.