- AllProduct Category
-
Explosion-proof Electric/Steam/Hot Water Heater Blowers
Humidifier and Dehumidifier in One
Rotary Dehumidification Unit - Customized
Mobile Air Conditioner/Portable Air Cooler
Fan Coil Unit/Air Handling Unit
Smart Dehumidifier Unit
Explosion-proof Modular Air Handling Unit / Swimming Pool Dehumidifying Air Handling Unit
Explosion-Proof Rooftop AC Series
Explosion-Proof Cold Water (Hot Water) Unit Series
Explosion-Proof Oven
Explosion-proof Air curtain Machine
Explosion-proof Temperature and Humidity Control Unit/Non-standard Temperature and Humidity Control System
Industrial Air Conditioning / Explosion-proof Industrial Air Conditioning
Cabinet Air Conditioners / Explosion-Proof Cabinet Air Conditioners
Explosion-proof Fan Coil Unit
Explosion-Proof Refrigerator
Explosion-proof Air Conditioner
Explosion-Proof Dehumidifier
Humidifier/Blast-Proof Humidifier
Dehumidifier


详情描述
The YingTeng FP series fan coil units integrate advanced technologies from similar products domestically and internationally. In accordance with national standards, after numerous trials and tests, a series of technical design improvements have been efficiently implemented, resulting in superior performance, wide applications, a complete range of types, high efficiency, and low noise. The series includes horizontal concealed, horizontal exposed, vertical concealed, vertical exposed, and cassette units. When paired with air handling units, they are extensively used in low-noise environments such as hotels, hospitals, office spaces, high-end conference halls, and exhibition halls, making them an ideal terminal device for centralized air conditioning systems.
Product Specifications
Model: FP136 (KC)
Brand: YingTeng
Airflow (m³): 1360
Cooling Capacity (W): 7200
Heat (W): 10800
Noise dB(A): ≤46
Cold water supply temperature: 7℃-12℃
Hot Water Supply Temperature: 40℃-60℃
Working Pressure (KPa): 1.6
Static Pressure: 30 Pa / 50 Pa
Power: 220V/50Hz
In and Out Pipe: ZG3/4
Condensate Drain Pipe: ZG3/4
Dimensions (Length x Width x Height mm): 830 x 830 x 390
Note: The data in the table are the measured values under the test conditions specified in the national standard for "Fan-coil Units" (GB/T19232-2003).
1. Cold supply operating parameters: Inlet air dry bulb temperature DB=27℃, wet bulb temperature WB=19.5℃.
Cold water inlet temperature: 7°C, outlet temperature: 12°C.
Heating operating parameters:进口 air dry bulb temperature DB=21℃, incoming water temperature 60℃.
2. Noise Measurement: Values measured at a distance of 1 meter from the front and above/below the equipment in an anechoic chamber.
3. Standard configuration of the vertical concealed unit features an outdoor static pressure of 12 Pa.
4. Water resistance refers to the resistance at the rated flow rate; input power refers to the input power at high airflow.
5. When selecting a combination of cold and hot dual coil unit, refer to the main technical parameters in the table above. A row of heat capacity is approximately 40% of three rows, low static...
The air volume loss in pressurizing units is approximately 10%, and the static pressure loss in high-pressure units is about 20%.
Product Features
Available in horizontal surface mount, horizontal concealed mount, vertical surface mount, vertical concealed mount, ceiling mount, cabinet mount, wall-mounted series, etc.
Low overall height, saving building space.
High cooling (heating) capacity, low noise, three-speed motor for adjustable air volume, meets various usage requirements.
The entire unit is made of hot-dipped galvanized steel, copper tubes, and aluminum fins, offering strong corrosion resistance.
The drip pan is fully molded, and the insulation is applied using a full-pressure bonding technique, eliminating concerns about condensation.
Equipped with exhaust and drain functions, ensuring thorough heat exchange and preventing pipe cracking due to freezing.
The evaporator is made by mechanical tubing with copper pipes and high-efficiency aluminum fins.
The unit employs an efficient aluminum finned heat exchanger with a low-noise fan configuration, enhancing heat exchange and maximizing the heat exchanger's thermal transfer efficiency.
精密 design allows for either left or right hand spiral ordering options. Upon request, an automatic temperature control unit can be customized for precise temperature regulation at the controlled location; (temperature control unit to be ordered separately)
The motor is an energy-saving fixed phase capacitor motor, equipped with imported high-precision ball bearings that can self-lubricate. The motor shafts are all treated with quenching and hard chrome, ensuring durability and easy disassembly at fixed points. The motor leads are all protected with metal hoses, meeting international standards.
The static pressure at the outlet of a standard coiled air outlet is 0~12Pa, while for the residual pressure type, it is 30Pa (or ≤50Pa), with the code H.
The water tray and insulation are molded, with an overall adhesive process, ensuring durability and no welding marks; the exterior is attractive and lightweight, with no condensation or dripping. The exposed pipe is made from plates produced by Shanghai Baogang, which are spray-painted; the concealed pipe is made from galvanized steel or fingerprint-resistant steel.
The coiled tubing is made from seamless copper tubes with corrugated aluminum fins, formed through hydraulic or mechanical expansion. The interior of the coil casing is lined with sound-absorbing and insulating materials. The copper tubes are arranged in an interlaced pattern, offering exceptional heat transfer performance and extremely low air resistance.