- AllProduct Category
-
Explosion-proof Electric/Steam/Hot Water Heater Blowers
Humidifier and Dehumidifier in One
Rotary Dehumidification Unit - Customized
Mobile Air Conditioner/Portable Air Cooler
Fan Coil Unit/Air Handling Unit
Smart Dehumidifier Unit
Explosion-proof Modular Air Handling Unit / Swimming Pool Dehumidifying Air Handling Unit
Explosion-Proof Rooftop AC Series
Explosion-Proof Cold Water (Hot Water) Unit Series
Explosion-Proof Oven
Explosion-proof Air curtain Machine
Explosion-proof Temperature and Humidity Control Unit/Non-standard Temperature and Humidity Control System
Industrial Air Conditioning / Explosion-proof Industrial Air Conditioning
Cabinet Air Conditioners / Explosion-Proof Cabinet Air Conditioners
Explosion-proof Fan Coil Unit
Explosion-Proof Refrigerator
Explosion-proof Air Conditioner
Explosion-Proof Dehumidifier
Humidifier/Blast-Proof Humidifier
Dehumidifier


详情描述
YingTeng Modular Explosion-Proof Air Conditioning Unit
Model: BZKT-90Ex(Z)
Brand: YingTeng
Cooling Capacity (kW): 90
Heating Output (kW): 90
Airflow (m³/h): 15,000
Excess Pressure (Pa): 300/900
Noise Level (dB(A)): 72
Auxiliary Electric Heating (kW): 25
Temperature Range and Accuracy: 18-25% ± 2.0%
Power Supply: 380V 50Hz, 3-phase 4-wire system
Total Generator Capacity (kW): 58
Compressor Type: Hermetically Sealed Scroll
Compressor Quantity: 2
Compressor Power (kW): 22.4
Refrigerant Type: R-22
Evaporator Type: Copper Tube with Aluminum Fin
Number of Condenser Fans/Power (kW): 1/3
Dimensions (mm)
Mixed Segment: 600
Initial Efficiency Section: 400
Cooling Plate Water Stop: 600
Heating Section: 300
Fan Section: 1650
Middle Section: 800
Medium Efficiency Section: 400
Supply Section: 600
Width: 1850
Height: 1500
Air Filter Types: Preliminary + Medium Efficiency
Centrifugal Fan Power (kW): 7.5
Weight (kg): 1500
Ex db eb ib mb lIB T4 Gb
Manufacturer: Henan Tongteng Explosion Proof Electrical Equipment Co., Ltd.
The Yingteng explosion-proof air conditioning unit is marked with Ex db eb ib mb lIB T4 Gb.
Note: The above technical specifications are for reference only, and the actual product should be used as the standard.
1. Refrigeration nominal operating conditions: Indoor return air dry bulb temperature 27°C, wet bulb temperature 19°C; Outdoor ambient air dry bulb temperature 35°C.
2. Heating Nominal Operating Conditions: Indoor return air dry bulb temperature 20°C, hot water inlet temperature 19°C; steam pressure 0.2 MPa;
3. The beauty method can be selected from electric heating, hot water heating, or steam heating; electric regulating valves are required for hot water and steam heating.
4. When the unit is cooling, the ambient temperature must not be below 18°C; if a specific requirement is needed for ordering, please specify clearly.
5. Specifications may be modified or updated without prior notice.
The YingTeng series of explosion-proof air conditioning units adhere to the following standards:
GB/T 3836.1-2021 "Explosive Atmospheres *Part 1: Equipment General Requirements"
GB/T 3836.2-2021 "Explosive Atmospheres - Part 2: Equipment protected by隔爆外壳 'd'"
GB/T 3836.3-2021 "Explosive Atmospheres *Part 3: Equipment protected by intrinsic safety 'i'"
GB/T 3836.4-2021 "Explosive Atmospheres - Part 4: Equipment protected by intrinsic safety 'i'"
GB/T 3836.9 - 2021 "Explosive Atmospheres *Part 9: Equipment protected by "m" type enclosures"
GB/T 3836.15-2017 "Explosive Atmospheres *Part 15: Design, Selection, and Installation of Electrical Equipment"
The Yingteng modular explosion-proof air conditioning unit can operate normally under the following environmental conditions:
a) Altitude not exceeding 2,000m
b) Suitable for environments with temperatures ranging from -7℃ to 43℃, free of corrosive gases.
c) There are explosive hazard areas formed by mixtures of flammable gases, vapors, and air in groups II A, II B, and T1 to T4.
The "YingTeng" Series Combination Explosion-Proof Air Conditioning Units have been specially processed with explosion-proof technology, making them suitable for use in flammable and explosive areas in Zones 1 and 2. They are widely applicable in scientific research, oil, chemical, pharmaceutical, and power plant environments where IIA, IIB, T1 to T4 groups of combustible gases, steam, and air mixtures may pose explosion hazards. These combination explosion-proof air conditioning units are ideal for spaces with temperature requirements. The YingTeng combination explosion-proof air conditioning units have passed inspections by the National Quality Supervision and Inspection Center for Explosion-Proof Electrical Products and have been issued explosion-proof certificates and CCC certificates. They feature an aesthetically pleasing design, reasonable engineering, and ease of installation and maintenance. The entire series utilizes brand-name compressors, microcomputer intelligent control, digital display, and boasts low noise, stable performance, simple operation, and high safety reliability, making them popular in the market. (Customizable options include explosion-proof window-type air conditioners, explosion-proof duct-type air conditioners, explosion-proof ceiling-mounted air conditioners, explosion-proof fresh air air conditioners, explosion-proof marine air conditioners, explosion-proof corrosion-resistant air conditioners, explosion-proof high-temperature air conditioners, explosion-proof cold storage air conditioners, explosion-proof combination air conditioning units, and explosion-proof multi-split air conditioning units, etc.).
A new generation explosion-proof air conditioning unit with an integrated cooling source, specifically developed for modular explosion-proof air conditioning systems. It revolutionizes the traditional design concept of combining chilled water systems with modular air handling units, replacing the complex water system with a direct expansion refrigerant system. This simplifies the system structure, increases the evaporation temperature of the refrigerant, reduces construction and equipment operation costs, and is a classic example of a simple and efficient design philosophy.
Combi explosion-proof air conditioning units have wide application areas: This product is a professional explosion-proof air conditioning unit designed for purification engineering and other air conditioning projects, capable of meeting air conditioning, temperature and humidity control, dust-free, sterile, noise reduction, micro-processing programmable automatic control, easy transportation, and simple installation requirements. It effectively resolves the problems caused by different air volume and pressure head requirements in purification and air conditioning. It fully showcases the characteristics of direct expansion air conditioning while also meeting the various process requirements of the purification section, marking an innovation in purification-type explosion-proof air conditioning units. Humanized function classification: explosion-proof air conditioning units are divided into conventional and flexible types.
Standard unit, all functional sections provided by our company, including the mixing air section, pre-effectiveness section, cooling section, heating section, humidification section, medium effectiveness section, and air outlet section, etc. The cooling section is of direct expansion type, and the functional sections can be selected according to customer requirements.
Flexible type units consist of dividing the entire unit into two parts, where the customer is responsible for the pre-filtration, medium-efficiency sections of the purification air conditioning, the matching fan section, and the entire casing. Our company provides the necessary cooling and heating sources, humidifiers, and the corresponding electrical control components. Based on customer requirements, we offer types such as single cooling, heating and cooling, constant temperature and humidity, low temperature and low humidity, and 100% fresh air. Rich product series: BZ series direct expansion purification packaged explosion-proof air conditioning units, with a very diverse product line, cooling capacities of 8~340kW, air volumes of 1500~50000m³/h, suitable for a wide range of purification and other environmental air conditioning projects.
Features of Modular Explosion-proof Air Conditioning Units
Case: Special-purpose aluminum alloy frame with cold-bridge prevention, double-layer steel plate, processed by Japanese AMADA, one-time bending forming technology, surface coating.
Insulation: Made of polyurethane high foam material, featuring low thermal conductivity, high water resistance, aging resistance, flame retardancy, and non-toxicity.
Centrifugal fan: Utilizing high-performance, low-noise centrifugal fans with advantages such as high air volume, high static pressure, low noise, and stable operation.
Heat Exchanger: Milled in the USA at the OAK production line, with a brazed plate-style refrigerant direct expansion coil, offering extremely high heat exchange efficiency.
Electric heater: Stainless steel finned electric heater, mainly used for winter heating, also suitable for defrosting equipment to protect coils.
Humidifiers: Choose to install a humidifier when controlling the humidity of the air output is required. Types available include dry steam, electrode, and water film humidifiers, among others.
Control Method: Initially use imported or domestically produced high-performance instruments, offering high control accuracy and reliability. Control instruments can be pre-installed with remote control interfaces for easy remote centralized control by users (please specify at the time of ordering).
Air-cooled Condensing Unit
Compressor: Utilizes high-performance imported fully enclosed or semi-enclosed scroll compressors, ensuring safety, reliability, and high energy efficiency. Shell: Machined by Japanese AMADA equipment, single-bend forming technology, made of stainless steel, suitable for outdoor placement without rust concerns. Refrigeration accessories: Expansion valves, solenoid valves, high and low-pressure controllers, etc., all use internationally renowned brands.
Outdoor Unit Installation
★The installation location should ensure that the hot air passing through the condenser is not re-circulated back into the unit or drawn into the exhaust air of another unit, and there should be sufficient space for maintenance of the equipment.
★There should be no obstructions in the channels for the unit's exhaust and intake air.
★The unit arrangement should be in a well-ventilated area to dissipate the hot air expelled by the unit and to draw in cooler air.
★The unit should be mounted on a sturdy and level base, which must have sufficient strength to bear the weight of the unit and the vibration during operation.
★Avoid installation in dirty or oily environments.