- AllProduct Category
-
Explosion-proof Electric/Steam/Hot Water Heater Blowers
Humidifier and Dehumidifier in One
Rotary Dehumidification Unit - Customized
Mobile Air Conditioner/Portable Air Cooler
Fan Coil Unit/Air Handling Unit
Smart Dehumidifier Unit
Explosion-proof Modular Air Handling Unit / Swimming Pool Dehumidifying Air Handling Unit
Explosion-Proof Rooftop AC Series
Explosion-Proof Cold Water (Hot Water) Unit Series
Explosion-Proof Oven
Explosion-proof Air curtain Machine
Explosion-proof Temperature and Humidity Control Unit/Non-standard Temperature and Humidity Control System
Industrial Air Conditioning / Explosion-proof Industrial Air Conditioning
Cabinet Air Conditioners / Explosion-Proof Cabinet Air Conditioners
Explosion-proof Fan Coil Unit
Explosion-Proof Refrigerator
Explosion-proof Air Conditioner
Explosion-Proof Dehumidifier
Humidifier/Blast-Proof Humidifier
Dehumidifier


详情描述
Yinteng New Fresh Air Roof Top Explosion Proof Air Conditioner
Product Specifications
Model: BZKT-360Ex (490X)
Brand: YingTeng
Cooling Capacity: 490.5 kW (422,440 kcal/h)
Heating Capacity: 507.2 kW (436,623 kcal/h)
Energy Regulation: 0, 25, 50, 75, 100%
Airflow: 49,000 m³/h
Static Pressure Outside: ≥800 Pa
Temperature Range and Accuracy: 18 - 32℃ ±2℃
Power: 380V 50Hz, three-phase four-wire system
Rated Power: Cooling 187.8kW, Heating 183.6kW
Compressor: Semi-hermetic screw type, quantity 2
Evaporators, Condensers: Copper tube with aluminum fin
Fan Blower: Type double-inlet centrifugal (belt-driven), Power 37kW
Condenser Fan: Type - Low Noise Axial, Quantity - 8, Power - 12 kW
Filter: Plate-type Pre-Effect Type
Auxiliary Electric Heating (Optional): Power 108kW, Energy Adjustment 0, 33, 66, 100%
Dimensions: Length 7490mm, Width 3500mm, Height 2600mm
Weight: 7,160 kg
Ex db eb ib mb lIB T4 Gb
Manufacturer: Henan Tongteng Explosion Proof Electrical Equipment Co., Ltd.
The Yingteng explosion-proof air conditioner features the explosion-proof marking Ex db eb ib mb lIB T4 Gb.
Note: The above technical specifications are for reference only; the physical unit shall prevail.
1. Refrigeration nominal operating conditions: Indoor return air dry bulb temperature 27°C, wet bulb temperature 19°C; outdoor ambient air dry bulb temperature 35°C.
2. Heating nominal operating conditions: indoor return air dry bulb temperature 20°C, hot water inlet temperature 19°C; steam pressure 0.2 MPa.
3. The beauty method can be chosen from electric heating, hot water heating, or steam heating; electric regulating valves are required for hot water and steam heating.
4. The ambient temperature during the unit's refrigeration operation must not be below 18°C; if a specific requirement is needed for ordering, please clarify.
5. Specifications may change or be updated without prior notice due to product improvements.
This series of products complies with the following standards:
GB/T 3836.1-2021 "Explosive Atmospheres Part 1: Equipment General Requirements"
GB/T 3836.2-2021 "Explosive Atmospheres Part 2: Equipment 'd' protected by explosion-proof enclosures"
GB/T 3836.3-2021 "Explosive Atmospheres *Part 3: Equipment protected by intrinsic safety 'i'"
GB/T 3836.4-2021 "Explosive Atmospheres - Part 4: Equipment protected by intrinsic safety 'i'"
GB/T 3836.9-2021 "Explosive Atmospheres *Part 9: Equipment protected by "m" type enclosures"
GB/T 3836.15-2017 "Explosive Atmospheres *Part 15: Design, Selection, and Installation of Electrical Equipment"
Explosion-proof air conditioners can operate normally under the following environmental conditions:
a) Altitude not exceeding 2,000m.
b) Suitable for environments with temperatures ranging from -7℃ to 43℃, free of corrosive gases.
c) There are explosive hazard areas formed by mixtures of flammable gases, vapors, and air from groups II A, II B, and T1 to T4.
The "YingTeng" explosion-proof air conditioning series has been processed with special explosion-proof technology, making it suitable for widespread use in flammable and explosive areas in Zones 1 and 2. It is ideal for research, oil, chemical, pharmaceutical, and power plant environments where IIA, IIB, T1-T4 groups of combustible gases, steam, and air mixtures pose explosion hazards. Explosion-proof air conditioners are suitable for spaces with temperature requirements. The YingTeng explosion-proof air conditioners have been inspected and certified by the National Quality Supervision and Inspection Center for Explosion-Proof Electrical Products, receiving both explosion-proof certification and explosion-proof CCC certification. They feature an aesthetically pleasing design, reasonable structure, and ease of installation and maintenance. The entire series utilizes branded compressors, microcomputer intelligent control, digital display, and boasts low noise, stable performance, simple operation, and safety. They are highly favored in the market. (Customizable options include explosion-proof window-type air conditioners, explosion-proof duct-type air conditioners, explosion-proof ceiling-mounted air conditioners, explosion-proof fresh air air conditioners, explosion-proof marine air conditioners, explosion-proof corrosion-resistant air conditioners, explosion-proof high-temperature air conditioners, explosion-proof cold storage air conditioners, explosion-proof modular air conditioners, and explosion-proof multi-split air conditioners, etc.).
Roof-mounted explosion-proof air conditioning units are a full-air system designed for indoor air treatment, integrating cooling, heating, dehumidification, humidification, ventilation, and air purification functions into medium to large-scale air conditioning equipment. This product combines modular air handling units with direct expansion air conditioning technology, enabling centralized comprehensive control of cooling and air conditioning. It features high efficiency and energy saving, simple system, stable performance, compact structure, high control accuracy, safety and reliability, low noise, high static pressure, minimal vibration, high corrosion resistance, good sealing, excellent rain and dust protection, easy installation, and attractive appearance. The microcomputer control ensures the product's performance and quality are fully demonstrated and utilized.
The unit is divided into two sections: the compression and condensation section, and the air handling section. The compression and condensation section is assembled in a modular manner, while the air handling section features a modular design with functional sections. The housing is constructed with a cold-bridge-free aluminum alloy frame and a polyurethane sandwich panel structure with double-sided steel plates. The unit's assembly methods are versatile and easy to install, suitable for placement on rooftops or outdoor open spaces without the need for a dedicated machine room. The product is ideal for large industrial sites such as factories and workshops in areas with limited water access or scarce water resources, as well as for full-air conditioning systems in comfort-oriented locations such as hospitals, shopping malls, supermarkets, restaurants, and office buildings.
Roof-mounted Explosion-proof Air Conditioning Unit Product Features
1. Comprehensive Variety and Specifications: Rooftop air conditioning units are categorized into three series by function: Cold Air Type (L), Heat Pump Type (R), and Constant Temperature and Humidity Type (H). The Constant Temperature and Humidity Type is suitable for process air conditioning environments with high requirements for temperature and humidity, while the Cold Air Type and Heat Pump Type are ideal for comfort air conditioning spaces.
Products are available for custom production with cooling capacities ranging from 12kW to 490kW, catering to requirements for different high air volume and space-specific air conditioning locations.
Products are categorized into standard, purification, and fresh air series based on applicable usage locations, and various functional modules can be optionally added for convenient realization of cooling, heating, dehumidification, humidification, air purification, noise reduction, and energy-saving fresh air functions.
2. No dedicated machine room required, save on investment: The frame of this series of units is treated with anti-corrosion and waterproofing, allowing the entire unit to be placed on the roof or outdoor space, eliminating the need for a machine room and saving on building space and construction investment costs: The unit is a full-air system with no cooling water or chilled water system, which saves on chilled water pumps, cooling water pumps, cooling towers, fan coils, and piping accessories.
Investment readiness has reduced the construction cost. 3. Convenient transportation and easy installation: The unit design features two structural forms: Standard and Purification. The Standard unit, with a cooling capacity below 140kW, is designed as an integrated structure, while above 140kW, it is a split structure, facilitating transportation and installation. The Purification unit is modularly designed, with configurable functional sections as needed, offering simple configuration and flexibility. The volume of each functional section
Small, lightweight, and customizable according to on-site conditions, easy to transport and install. 4. Cold bridge-free frame, low air leakage rate: The air handling sections use cold bridge-free aluminum alloy frames, with panels made of polyurethane high-pressure foam insulated sandwich panels (outer panel: electrostatically coated steel plate, inner panel: galvanized steel plate). The frame and panels are equipped with special sealing insulation strips and a unique outdoor rainproof structure design, ensuring outdoor operation of the unit.
With required corrosion and rust resistance, vibrant colors, and elegant appearance. 5. The unit employs a brand-name fully enclosed scroll compressor, offering stable operation, reliable performance, and high refrigeration efficiency: Customized units with heat recovery for energy conservation and environmental protection can also be provided upon customer request.
6. Equipped with a direct-drive low-noise axial flow fan and a rear-tilt centrifugal exhaust fan, with effective anti-vibration measures in place to ensure the unit operates smoothly and reliably with low noise and minimal vibration.
7. A variety of refrigeration accessories and control components are for international brands, featuring high system operation reliability and stable performance.
8. Both the evaporator and condenser are copper-tube-aluminum-finned heat exchangers, designed with computer optimization and manufactured on a dedicated heat exchanger production line, ensuring high efficiency and energy savings.
9. Standard units feature intelligent instrument control, and industrial-grade programmable logic controllers (PLCs) can be optionally selected to meet customer requirements. Standard purification units are equipped with PLC control running optimized programs. They also come with fault self-diagnosis and alarm functions. The controllers are equipped with standard RS485 communication interfaces, enabling convenient remote control from a distance or connection to an intelligent control system, ensuring optimal equipment efficiency and reducing operating costs.
10. The unit's return air can be in various forms, such as horizontal supply, side supply on either side of the unit, upward supply, and downward supply, making it particularly suitable for the renovation of air conditioning systems in old buildings (simply reroute the existing return air ducts to connect with the main unit on the roof): Additionally, replacing the main unit that has reached the end of its service life is also convenient, alleviating any concerns for the users.
11. The units can be treated for explosion-proof and corrosion resistance according to specific requirements of the application. They are widely used in industries such as petrochemicals, metallurgy, and more. The explosion-proof marking for the units is ExibeibibmbllBT4Gb. There are also products with the explosion-proof marking ExibeibibmbllcT4Gb. Please communicate and confirm with our technical department before placing an order.
Roof Type Explosion-Proof Air Conditioning Unit Order Instructions
Users may select and combine various function segments based on their needs. It is recommended to provide a diagram illustrating the combination of function segments when placing an order, and the following data should be provided: (No need for standard models) 1. Heat and cold requirements, and heating methods. Note that the cooling capacity in the performance parameters table does not consider the change in air handler power due to changes in external excess pressure, which may cause a change in the amount of heat dissipated.
2. Functional Segment Name, Quantity, refer to Section 6, Examples of Functional Segment Combinations.
3. Provide excess pressure outside the machine.
4. If there is a fresh air section, the user must provide the fresh air volume and operating conditions. Standard fresh air operating conditions are dry bulb temperature 35°C, wet bulb temperature 28°C.
5. Standard configuration includes a pleated non-woven filter for the primary filter, and a bag-type non-woven filter for the medium efficiency filter:
6. Aircraft Control Panel Arrangement: The control panel on the right side facing the airflow direction is referred to as right-hand type, denoted by "Y." The control panel on the left side facing the airflow direction is referred to as left-hand type, denoted by "Z." The definition of the control panel includes the inspection door side, the system intake and exhaust pipes, the heating medium intake and exhaust pipes, and the operating side.
7. Are you requiring a damper and its type (manual or electric)? If not specified, the product will not include a damper.
8. Do you need a remote control box, and what is the desired length of the remote control cable?
9. For hot water and steam heating units, the corresponding electric regulating valves must be selected.
10. The ambient temperature should not be below 18°C during the refrigeration of a single-cooling unit; please specify this requirement when placing an order.
Roof Type Explosion Proof Air Conditioning Unit Functional Segment Combination Description
The functional sections of the air treatment part offer multiple combinations, allowing users to flexibly choose according to their actual needs.
b. Additional functional sections can be added or removed from the air handling section of the aforementioned unit as needed.
c, The air handling section of the unit offers additional functional modules for user selection, such as sound absorption sections, heat recovery sections, and ozone purification sections, etc.
d. Our explosion-proof rooftop air conditioning units are a featured product, suitable for use in flammable and explosive environments. For details, please consult our technical department.
e. Standard and Basic Function Unit performance parameters and external dimensions can be found in this sample. Performance parameters and outdoor static pressure can be adjusted according to the actual needs of the customer. For details, please consult our technical department.
f. There are various methods for returning air, such as top return, side return, and bottom return, and the same goes for supplying air, including top supply, side supply, end supply, and bottom supply. You can choose flexibly based on your needs; just specify the type of air supply in your order.