Overview of Self-limiting Electric Heat Trace
Self-limiting temperature electric heating tape, also known as self-regulating electric heating tape, is a new generation of strip-shaped constant temperature electric heating product. It is composed of high polymer conductive carbon particles, two parallel busbars, and an insulating layer. The PTC heating element has a high positive temperature coefficient of resistance and is connected in parallel.
Self-limiting temperature electric heating tape features
Self-limiting heating tape can automatically control the heating temperature and adjust the output power according to the temperature of the heated object; it can be cut to any length or extended within a certain range; allows multiple overlaps without the risk of overheating and burning; easy to maintain and energy-saving.
High-temperature electric tracing heater structure

Tinned Soft Copper Wires
②PTC Fluoropolymer Core Tape (Heating Layer)
③ Improved Polyolefin Insulation
④ Metal Shielding Layer (Tinned Copper Wire or Aluminum Magnesium Alloy Wire)
⑤ Improved Polyolefin Insulation (Flame-retardant Polyolefin, PTFE F46 Insulation)
Product Models: GBR (GBR-J, GBR-P, GBR-PF, GBR-PF46, ZR-GBR......)
Corresponding Model: GBR (GXW, GKW, GBW, GWK, GHR, GBR) corresponds to the overseas model of the RAYCORN XTV series.
Technical Specifications
1、Standard Colors: Brown, Red
2. Temperature Range: Ambient surface temperature of 10°C to 135°C ±5°C, withstand temperature of 155°C
3. Limited construction temperature: -30℃
4. Thermal Stability: After 300 cycles of alternating temperatures between 10°C and 99°C, the heat output of the electric heat tracing maintains above 95%.
5. Maximum bend radius: 25mm inner diameter for electric tracing belts
6. Insulation Resistance: For a heating cable length of 100m, at an ambient temperature of 75°C, the insulation resistance (between the conductor and the shield) shall not be less than 3000MΩ after a 1-minute test with a 2500VDC megger.
7. Single power source usage length: 100 meters with 7X0.5 core wire, 120 meters with 19X0.32 core wire.
8. Operating Voltage: 110V, 220V, 380V
9. Power Output: 35W/m, 40W/m, 45W/m, 50W/m at 10°C
Ex-proof marking: Ex e II T4 Gb
Product Advantages
1. The heated pipeline maintains uniform temperature, ensuring safety and reliability.
2. Low installation and operation costs, easy maintenance
3. Energy Conservation
4. During intermittent operation, the heating start-up is rapid
5. Easy for automated management
6. Environmentally Pollution-Free
7. Heating Tracing Systems for Complex Pipelines and Long-Distance Installations
8. Suitable for Instrument Box Anti-Freeze