Equipment Advantages:For general concentration organic wastewater, which contains pollutants such as ammonia nitrogen and total nitrogen.The EOT biological integrated reactor can simultaneously remove general concentrations of COD, NH3, and TN from wastewater, allowing for direct compliance with discharge standards. This equipment is suitable for COD levels of 500-2000 mg/L, NH3...3Industrial wastewater with N 50-600mg/L, TN 50-600mg/L.
This equipmentFloor AreaSmall, saving compared to traditional pools60% land, especially suitable for wastewater treatment projects with limited land availability. The system also operates with low running costs and is easy to operate and maintain.
Engineering Case Studies:
Liaoning Chemical IndustryCompanyWastewater after front-end treatmentCOD1000-1500mg/L,NH3-N 400-600 mg/L, TN 500-650 mg/L treated through an EOT biological integrated reactor, effluent COD 200 mg/L, NH3-N 5-10 mg/L, TN 30-50 mg/L, fully meet the park's emission requirements.
A Shanghai company's wastewater simultaneously containsCOD, NH3-N, TN, where COD is 2000-3000 mg/L, NH3-N, and TN.3-N 30-50 mg/L, TN 60-100 mg/L, water volume 10 m³/day. Wastewater meets standards after EOT treatment and is discharged accordingly.
The EOT biological integrated reactor is widely used in the wastewater treatment of industries such as food processing, chemical engineering, and brewing.